154N
Compensated
SENSOR SOLUTIONS ///154N 04/2018
PERFORMANCE SPECIFICATIONS
Unless otherwise specified: Supply Current: 1.5mA, Ambient Temperature: 25°C
1psi: -0.30 to 0.30
5psi: -0.20 to 0.20
Temperature Error – Offset
15psi: -0.75 to 0.75
>15psi: -0.50 to 0.50
Thermal Hysteresis – Span
Thermal Hysteresis – Offset
Long Term Stability – Span
Long Term Stability – Offset
Insulation Resistance (50V
DC
)
Output Noise (10Hz to 1KHz)
Response Time (10% to 90%)
1psi: 10X max
5psi: 3X max
1psi: 12X max
5psi: 4X max
1psi: 0 to 50
5psi: 0 to 70
Liquids and Gases compatible with 316/316L Stainless Steel
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 316/316L
Stainless Steel
Notes
1. For amplified output circuits, 3.012V ±1% interchangeability with gain set resistor. See application schematic.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over the compensated temperature range with respect to 25°C.
5. Guarantees output/input ratiometricity.
6. Load resistance to reduce measurement errors due to output loading.
7. Between case and sensing element.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
9. Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
10. Standard gage units are not recommended for vacuum applications. For vacuum applications below 1/2 atmosphere, consult factory.
11. Device Marking:
Each part shall be identified with Model Number, Pressure Range, Type, Lot Number, Serial Number and Date Code.
12. Shipping/Packaging:
The stainless steel diaphragm is protected by a plastic cap. Each unit will be packaged individually in a plastic vial with anti-static foam.