CPC1219YA

I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
DS-CPC1219-R06
1
CPC1219
e
3
Pb
Voltage-Controlled, Single-Pole,
Normally Closed, 4-Pin SIP OptoMOS
®
Relay
Part # Description
CPC1219Y 4-Pin SIP (8-Pin Body) (25/tube)
Parameter Rating Units
Blocking Voltage 60 V
P
Load Current 200 mA
rms
/ mA
DC
On-Resistance (max) 16
Input Voltage to operate 5-12 V
Applications
Features
Description
Ordering Information
Pin Configuration
Security
Passive Infrared Detectors (PIR)
Data Signalling
Sensor Circuitry
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Energy Meters
Medical Equipment—Patient/Equipment Isolation
Aerospace
Industrial Controls
Designed for use in Security Systems Complying
with EN50130-4
Voltage-Controlled Operation
2500V
rms
Input/Output Isolation
100% Solid State
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Immune to Radiated EM Fields
Small 4-Pin SIP Package
Auto Pick & Place, Wave Solderable
The CPC1219 is a voltage-controlled,
single-pole, normally closed (1-Form-B) optically
coupled solid state relay in a 4-pin Single In-line
Package (SIP). IXYS Integrated Circuits Division's
patented OptoMOS architecture makes available the
optically coupled technology necessary to activate the
output's efficient MOSFET switches while providing a
2500V
rms
input-to-output isolation barrier. Control of the
isolated output is accomplished by means of a highly
effective GaAlAs infrared LED at the input. An internal
resistor in series with the LED enables the voltage-
controlled operation of the input.
Because the input is solid state there is no need for
snubbers or "catch" diodes to suppress the inductive
fly-back transient voltage normally associated with
EMR coils.
CPC1219 Pinout
Switching Characteristics
of Normally Closed Devices
Approvals
UL 508 Approved Component: File E69938
CSA Certified Component: Certificate 1172007
Form-B
I
F
10%
90%
I
LOAD
t
on
t
off
Load LoadIN + IN -
1234
I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R06
CPC1219
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 60 V
P
Reverse Input Voltage 5 V
Input Control Voltage 15 V
Input Power Dissipation 225 mW
Total Power Dissipation
1
800 mW
Isolation Voltage, Input to Output 2500 V
rms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1
Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous
1
-I
L
- - 200 mA
rms
/ mA
DC
Peak t10ms I
LPK
- - ±400 mA
P
On-Resistance
2
I
L
=200mA R
ON
--16
Off-State Leakage Current V
IN
=5V , V
L
=60V
P
I
LEAK
--1A
Switching Speeds
Turn-On (Output Closed)
V
IN
= 5V, V
L
= 10V
t
on
--5ms
Turn-Off (Output Open) t
off
--5ms
Output Capacitance V
IN
=5V, V
L
=50V, f=1MHz C
OUT
-25 - pF
Input Characteristics
Input Control Voltage
Output Open
I
L
= 200mA V
IN
- - 3.75 V
Output Closed 1 - - V
Recommended Operating Range 5 - 12 V
Reverse Input Current V
IN
= -5V I
R
--10A
Input Resistor - - 900 1000 1100
Common Characteristics
Capacitance, Input to Output - - - 1 - pF
1
Load current derates linearly from 200mA @ 25
o
C to 125mA @80
o
C.
2
Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25ºC
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC1219
www.ixysic.com
3
R06
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
0.28 0.42 0.56 0.700.35 0.49 0.63
Turn-On (ms)
Device Count (N)
25
20
15
10
5
0
Typical Turn-On Time
(N=50, V
IN
=5V, I
L
=100mA, T
A
=25ºC)
0.41 0.55 0.69 0.830.760.620.48
Turn-Off (ms)
Device Count (N)
25
20
15
10
5
0
Typical Turn-Off Time
(N=50, V
IN
=5V, I
L
=100mA, T
A
=25ºC)
35
30
25
20
15
10
5
0
Device Count (N)
4.9 5.0 5.25.1 5.55.3 5.4
Typical On-Resistance Distribution
(N=50, V
IN
=0V, I
L
=100mA, T
A
=25ºC)
On-Resistance (:)
1.23 1.25 1.271.22 1.24 1.26 1.28
V
IN
(V)
Device Count (N)
25
20
15
10
5
0
Typical V
IN
for Switch Operation
(N=50, I
L
=100mA, T
A
=25ºC)
25
20
15
10
5
0
1.23 1.25 1.271.22 1.24 1.26 1.28
V
IN
(V)
Device Count (N)
Typical V
IN
for Switch Dropout
(N=50, I
L
=100mA, T
A
=25ºC)
35
30
25
20
15
10
5
0
89 91 93 9590 92 94
Blocking Voltage (V
P
)
Device Count (N)
Typical Blocking Voltage Distribution
(N=50, V
IN
=5V, T
A
=25ºC)
V
IN
(V)
Turn-On (ms)
0
5101520
0.54
0.53
0.52
0.51
0.50
0.49
0.48
0.47
0.46
0.45
0.44
Typical Turn-On vs. V
IN
(I
L
=100mA, T
A
=25ºC)
V
IN
(V)
-40 -20 0 20 40
60 80 100
1.32
1.30
1.28
1.26
1.24
1.22
1.20
Temperature (ºC)
Typical V
IN
for Switch Operation
vs. Temperature
(I
L
=100mA)
V
IN
= 5V
Turn-On (ms)
-40
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
-20 0 20 40 60 80 100
Temperature (ºC)
Typical Turn-On vs. Temperature
(I
L
=100mA)
V
IN
(V)
Turn-Off (ms)
0
2 4 6 8 10 12 14 16 18
2.1
1.8
1.5
1.2
0.9
0.6
0.3
0
20
Typical Turn-Off vs. V
IN
(I
L
=100mA, T
A
=25ºC)
V
IN
(V)
-40
1.30
1.28
1.26
1.24
1.22
1.20
1.18
-20 0 20 40 60 80 100
Temperature (ºC)
Typical V
IN
for Switch Dropout
vs. Temperature
(I
L
=100mA)
Turn-Off (ms)
-40
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-20 0 20 40 60 80 100
V
IN
= 5V
Temperature (ºC)
Typical Turn-Off vs. Temperature
(I
L
=100mA)

CPC1219YA

Mfr. #:
Manufacturer:
IXYS Integrated Circuits
Description:
Solid State Relays - PCB Mount Single Pole Relay 60V 200mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet