File Name:USP-225-SPEC 2018-01-15
SPECIFICATION
USP-225-3.3
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT
(Typ.)
3.3V
40A
0 ~ 40A
132W
100mVp-p
2.97 ~ 3.6V
±2.0%
±0.5%
±1.0%
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
22ms/230VAC 22ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.93/230VAC PF>0.97/115VAC at full load
72%
2.2A115VAC
230VAC 1.1A
15A/115VAC 35A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
3.6 ~ 4.4V 5.5 ~ 7.4V 13.2 ~ 16.3V 16.5 ~ 20.2V 26.4 ~ 32.4V 52.8 ~ 64.8V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1, TUV EN60950-1 approved
, EAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
-20 ~ +65 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
220K hrs min. MIL-HDBK-217F (25 )℃
202*101.5*38mm (L*W*H)
0.85Kg; 16pcs/14.6Kg/0.76CUFT
77%
3.3A
1.6A
83% 84% 85% 86%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
100mVp-p
4.5 ~ 5.5V
100mVp-p
10.8 ~ 13.2V
100mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
250mVp-p
43.2 ~ 52.8V
5V
40A
0 ~ 40A
200W
12V
18.7A
0 ~ 18.7A
224.4W
15V
15A
0 ~ 15A
225W
24V
9.4A
0 ~ 9.4A
225.6W
48V
4.7A
0 ~ 4.7A
225.6W
USP-225-5 USP-225-12 USP-225-15 USP-225-24 USP-225-48
225W Single Output with PFC Function
Universal AC input / Full range
Built in active PFC circuit compliance to EN61000-3-2
Protections: Short circuit / Overload / Over voltage / Over temperature
Free air convection for 150W and forced air convection for 225W
High power density 4.7w/in
3
Active AC surge current limiting
U-bracket low profile:38mm
3 years warranty
■
Features :
USP-225 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
EMC IMMUNITY
EMC EMISSION
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os