Data Sheet ADuM6000
Rev. D | Page 5 of 16
REGULATORY INFORMATION
The ADuM6000 is approved by the organizations listed in Table 6. Refer to Table 11 and the Insulation Lifetime section for more
information about the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 6.
UL
1
CSA VDE
2
Recognized under UL 1577
component recognition
program
Approved under CSA Component Acceptance Notice #5A RI-16-2 package:
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
3
Reinforced insulation, 846 V peak
Single protection, 5000 V rms
isolation voltage
Basic insulation per CSA 60950-1-07 and IEC 60950-1, 600 V rms
(848 V peak) maximum working voltage
RW-16 package (pending):
Certified according to IEC 60747-5-2
(VDE 0884 Part 2):2003-01
Basic insulation, 846 V peak
RW-16 package:
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 380 V rms
(537 V peak) maximum working voltage
Reinforced insulation per IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
RI-16-2 package (pending):
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 400 V rms
(565 V peak) maximum working voltage
Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak)
maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM6000 is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 15 μA).
2
In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM6000 is proof-tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval.
3
In accordance with DIN V VDE V 0884-10, each ADuM6000 is proof-tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 7.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 mm
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) RW-16
Package
L(I02) 7.6 mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum External Tracking (Creepage) RI-16-2
Package
L(I02) 8.3 min mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance) 0.017 min mm Distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303, Part 1
Material Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)