ADuM6000 Data Sheet
Rev. D | Page 6 of 16
DIN V VDE V 0884-10 (VDE V 0884-10) AND IEC 60747-5-2 (VDE 0884 PART 2):2003-01 INSULATION
CHARACTERISTICS
This power module is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured
by protective circuits. The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10) or
IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval.
Table 8.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to IV
For Rated Mains Voltage ≤ 400 V rms I to III
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1
2
Maximum Working Insulation Voltage V
IORM
849 V
peak
Input-to-Output Test Voltage, Method B1 V
IORM
× 1.875 = V
pd(m)
, 100% production test, t
ini
= t
m
=
1 sec, partial discharge < 5 pC
V
pd(m)
1592 V
peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
1018 V
peak
Highest Allowable Overvoltage V
IOTM
6000 V
peak
Surge Isolation Voltage V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs, 50% fall time V
IOSM
6000 V
peak
Safety-Limiting Values Maximum value allowed in the event of a failure (see
Figure 2)
Maximum Junction Temperature T
S
150 °C
Total Power Dissipation @ 25°C P
S
2.78 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
Thermal Derating Curve
0
0.5
1.0
1.5
2.0
2.5
3.0
0
50 100 150 200
AMBIENT TEMPERATURE (°C)
SAFE LIMITING POWER (W)
08624-002
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values on Case Temperature, per DIN EN 60747-5-2