DRA-60-24

Model Encoding
Description
Features Applications
60W Single Output Switching Power Supply
DRA-60 series
Bauar
Sicherheit
egel gema
t gepruf t
od
be
www.
ID 2000000000
tuv.com
wac g
os
LPS
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Can be installed on DIN rail TS-35/7.5 or 15
Output Voltage adjustable through internal potentiometer
Output Current adjustable through external 1~10Vdc, PWM
signal or resistance
Cooling by free air convection
Pass LPS
LED indicator for power on
100% full load burn-in test
3 years warranty
Machine vision inspection system
Plant cultivation system
Output wattage
Output voltage
Series name
12DRA - -60
DRA-60 is one 60W AC/DC DIN rail power supply, featuring the adjustable output current. Users are
able to easily change the constant output current level, via 1~10Vdc, PWM signal or resistance.
DRA-60 can be mounted on DIN rail TS-35/7.5 or 15; in addition, the width of the unit is only 40mm that
it is well suited for the installation in a limited spacing. DRA-60 accepts the universal AC input between
90VAC and 264VAC; the efficiency is up to 87% that the entire series can operate, under free air convection,
from -30 through 70 .℃℃
File Name:DRA-60-SPEC 2018-01-12
SPECIFICATION
60W Single Output Switching Power Supply
DRA-60 series
MODEL
DC VOLTAGE
RATED CURRENT
CONSTANT CURRENT REGION
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.4
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
400ms, 90ms/230VAC 800ms, 90ms/115VAC at full load
50ms/230VAC 10ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
47 ~ 63Hz
85%
28.98 ~ 37.26V
87%
1.3A/115VAC 0.8A/230VAC
COLD START 30A/115VAC 60A/230VAC
95 ~ 108% rated output power
14.49 ~ 18.63V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1, approvedEAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 ) on output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
436.4K hrs min. MIL-HDBK-217F (25 )
40*90*100mm (W*H*D)
0.3Kg; 42pcs/13.6Kg/0.82CUFT
DRA-60-24
24V
3 ~ 24V
2.5A
0 ~ 2.5A
60W
150mVp-p
24 ~ 30V
±1.0%
±0.5%
±0.5%
DRA-60-12
12V
3 ~ 12V
5A
0 ~ 5A
60W
120mVp-p
12 ~ 15V
±1.0%
±0.5%
±0.5%
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 5)
EMC IMMUNITY
EMC EMISSION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power
supplies. (as available on http://www.meanwell.com)
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
File Name:DRA-60-SPEC 2018-01-12
AMBIENT TEMPERATURE ( )
LOAD (%)
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
175
LOAD (%)
230VAC
Input only
20
40
60
80
100
(VERTICAL)
-20 0 15 3004050-30 60 70
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
DIM+
DIM-
I/P
CONTROL
O.V.P.
O.C.P.
FG
OUTPUT CURRENT ADJUSTMENT OPERATION
Reference resistance value for output current adjustment (Typical)
signal or resistance between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
60KΩ
60%
60%
10KΩ
10K /NΩ 20K /NΩ 30K /NΩ 40K /NΩ 50K /NΩ 60K /NΩ 70K /NΩ 80K /NΩ 90K /NΩ
100K /NΩ
1V 4V 7V2V 5V 8V3V 6V 9V 10V
10%
10%
20KΩ
20%
20%
30KΩ
30%
30%
40KΩ
40%
40%
50KΩ
50%
50%
70KΩ
70%
70%
80KΩ
80%
80%
90KΩ 100KΩ
OPEN
OPEN
OPEN
90%
90%
100%
100%
Resistance
value
Applied Source
Percentage of rated current
Percentage of rated current
1 ~ 10Vdc for output current adjustment (Typical)
60%
60%
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
70%
70%
80%
80%
90%
90%
100%
100%
Duty value
Percentage of rated current
102%~108%
-----
102%~108%
102%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
60W Single Output Switching Power Supply
DRA-60 series
Derating Curve Static Characteristics
Block Diagram
Built-in 3 in 1 current adjustment function . Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM
Single Power supply
Multiple Power supplies
(N=Power supply quantity for simultaneous
current adjustment control)
File Name:DRA-60-SPEC 2018-01-12

DRA-60-24

Mfr. #:
Manufacturer:
Description:
DIN Rail Power Supplies 60W 24V 2.5A V and Current Adj.
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union