Ordering codes and packing units
Lead
spacing
mm
C
R
µF
Max. dimensions
w × h × l
mm
Ordering code
(composition see
below)
Ammo
pack
pcs./MOQ
Straight
terminals,
Reel
pcs./MOQ
Straight
terminals,
Untaped
pcs./MOQ
X2
safety
appr.
X = approval granted
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
M = ±20%
K = ±10%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
000 = Straight terminals, Untaped (standard lead
length 6 1 mm)
15 0.047 5.0 × 10.5 × 18.0 B32932A3473+*** 4680 5200 4000 X
0.068 5.0 × 10.5 × 18.0 B32932A3683+*** 4680 5200 4000 X
0.10 6.0 × 11.0 × 18.0 B32932A3104+*** 3840 4400 4000 X
0.15 7.0 × 12.5 × 18.0 B32932A3154+*** 3320 3600 4000 X
0.22 8.5 × 14.5 × 18.0 B32932A3224+*** 2720 2800 2000 X
0.33 9.0 × 17.5 × 18.0 B32932A3334+*** 2560 2800 2000 X
0.47 11.0 × 18.5 × 18.0 B32932A3474M*** 2200 1200 X
22.5 0.10 6.0 × 15.0 × 26.5 B32933A3104+*** 2720 2800 2880 X
0.15 6.0 × 15.0 × 26.5 B32933A3154+*** 2720 2800 2880 X
0.22 7.0 × 16.0 × 26.5 B32933A3224+*** 2320 2400 2520 X
0.33 7.0 × 16.0 × 26.5 B32933A3334+*** 2320 2400 2520 X
0.47 8.5 × 16.5 × 26.5 B32933A3474M*** 1920 2000 2040 X
0.47 10.5 × 16.5 × 26.5 B32933B3474+*** 1560 1600 2160 X
0.56 10.5 × 16.5 × 26.5 B32933A3564+*** 1560 1600 2160 X
0.68 10.5 × 18.5 × 26.5 B32933A3684+*** 1560 1600 2160 X
0.82 12.0 × 22.0 × 26.5 B32933A3824+*** 1800 X
1.0 12.0 × 22.0 × 26.5 B32933A3105M*** 1800 X
1.0 14.5 × 29.5 × 26.5 B32933B3105+*** 1040 X
1.5 14.5 × 29.5 × 26.5 B32933A3155+*** 1040 X
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 4 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units
Lead
spacing
mm
C
R
µF
Max. dimensions
w × h × l
mm
Ordering code
(composition see
below)
Ammo
pack
pcs./MOQ
Straight
terminals,
Reel
pcs./MOQ
Straight
terminals,
Untaped
pcs./MOQ
X2
safety
appr.
X = approval granted
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
M = ±20%
K = ±10%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
000 = Straight terminals, Untaped (standard lead
length 6 1 mm)
27.5 0.47 11.0 × 19.0 × 31.5 B32934A3474+*** 1400 1280 X
0.56 11.0 × 19.0 × 31.5 B32934A3564+*** 1400 1280 X
0.68 11.0 × 19.0 × 31.5 B32934A3684+*** 1400 1280 X
0.82 11.0 × 19.0 × 31.5 B32934A3824+*** 1400 1280 X
1.0 11.0 × 19.0 × 31.5 B32934A3105M*** 1400 1280 X
1.0 11.0 × 21.0 × 31.5 B32934B3105+*** 1400 1280 X
1.5 13.5 × 23.0 × 31.5 B32934B3155M*** 1200 1120 X
1.5 14.0 × 24.5 × 31.5 B32934D3155+*** 1040 X
2.2 18.0 × 27.5 × 31.5 B32934B3225+*** 800 X
37.5 1.0 12.0 × 22.0 × 41.5 B32936A3105+*** 1620 X
1.5 12.0 × 22.0 × 41.5 B32936A3155+*** 1620 X
2.2 14.0 × 25.0 × 41.5 B32936A3225+*** 1380 X
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 5 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Technical data
Max. operating temperature T
op,max
(T
op
= T
amb
+ self-heating)
+105 °C
Dissipation factor tan δ (in 10
-3
)
at 20 °C (upper limit values)
tan δ 1 kHz 10 kHz
C 1 µF 8 15
C > 1 µF 8
Insulation resistance R
ins
or time constant τ = C
R
R
ins
at 20 °C,
rel. humidity 65% (minimum
as-delivered values)
C
R
0.33 µF C
R
> 0.33 µF
30000 M 10000 s
DC test voltage 1312 V DC, 2 s (4.3 V
R
according to IEC 60384-14)
Passive flammability category
to IEC 40 (CO) 752
B
Capacitance tolerances
(measured at 1 kHz)
±10% (K), ±20% (M)
Rated AC voltage ( IEC 60384-14 ) 305 V (50/60 Hz)
Operating voltage V
op
at high
temperature
T
A
105 °C V
op
= 1.25 V
AC
(1000 h)
Damp heat test Test conditions
1. Temperature:
Relative humidity (RH):
Test duration:
Voltage value:
+85 °C ±2 °C
85% ±2%
1000 hours
240 V AC, 50 Hz
2. Temperature:
Relative humidity (RH):
Test duration:
Voltage value:
+40 °C ±2 °C
93% ±2%
2000 hours
305 V AC, 50 Hz
Limit values after damp heat test Capacitance change (C/C):
Dissipation factor change (tan δ):
tan δ/tan δ:
10%
5 10
-3
(at 1 kHz)
100% (at 10 kHz)
Insulation resistance R
ins
or time constant τ = C
R
R
ins
: > 10 M
Reference standard AEC-Q200
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 6 of 18Please read Cautions and warnings and
Important notes at the end of this document.

B32933B3474M000

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Film Capacitors FILM CAP X2 0.47uF 2 0% 305Vac LS 22.5mm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union