Typical applications
For connection in series with the mains
For severe ambient conditions
Capacitive power supply applications
Energy meters
Climatic
Max. operating temperature: 105 °C
Climatic category (IEC 60068-1):
40/105/56
Features
High stability of capacitance value
X2 safety approval (up to 2.2 µF)
RoHS-compatible
Construction
Dielectric: metallized polyester
Internal series connection
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Terminals
Parallel wire leads, lead-free tinned
Standard lead lengths: 6 1 mm
Special lead lengths available on request
Marking
Manufacturer's logo, lot number,
date code, rated capacitance (coded),
capacitance tolerance (code letter),
rated AC voltage (IEC),
series number, sub-class (X2),
dielectric code (MKT), climatic category
Delivery mode
Bulk (untaped, lead length 6 - 1 mm)
Taped (Ammo pack or reel)
Approvals
Approval mark Standards Certificate
EN 60384-14
IEC 60384-14
40028058
UL 60384-14 E97863
CSA E60384-14:09 E97863
Note: X2 safety approval for C ≤ 2.2 µF
Dimensional drawing
Dimensions in mm
Lead
spacing
±0.4
Lead
diameter
d
1
±0.05
Type
15 0.8 B32932
22.5 0.8 B32933
27.5 0.8 B32934
37.5 1.0 B32936
Marking examples
Metallized Polyester Film Capacitors (MKT) B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 2 of 18Please read Cautions and warnings and