LK-G
–2–
ASCTB198E 201604-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item
Specifications
10A, 1 mm .039 inch contact
gap type
16A, 1 mm .039 inch contact
gap type
16 A standard type
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 10A 277V AC 16A 277V AC
Max. switching power (resistive load) 2,770VA 4,432VA
Max. switching voltage 277V AC 277V AC
Max. switching current 10A (AC) 16A (AC)
Min. switching capacity (reference value)*
1
100mA 5V DC
Electrical
characteristics
Contact gap Min. 1 mm .039 inch —
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 20 ms (excluding contact bounce time.) (with diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 2×10
6
(at 180 times/min.)
Electrical
Min. 10
5
(at 6 times/min.)
(with diode)
Min. 5×10
4
(at 6 times/min.)
(with diode)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Air pressure: 86 to 106 kPa
Max. operating speed 6 times/min. (at rated load)
Unit weight Approx. 12 g .42 oz
1. Max. switching power (AC resistive load) 2. Ambient temperature characteristics and coil
applied voltage
100
10
1
0 10 100
16A type
10A type
Contact voltage, V
Contact current, A
0
220
180
140
100
60
0 1020304050607080
Carrying current: 10A
Carrying current:
16A
Coil & contact
no carrying current
Ambient temperature, °C
Coil applied voltage, %V
Pick-up voltage
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C 239°F
3-(1). Electrical life test (10A type)
Sample: LKG1aF-12V-10-1, 6 pcs.
Operation frequency: 6 times/min.
(ON/OFF = 1s: 9s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
277V AC
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
2
4
6
8
10
12
510
Drop-out voltage
Pick-up voltage
No. of operations, ×10
4
Pick-up and drop-out voltage, V
Max.
Min.
x
Max.
Min.
x
0
0
5
10
15
20
25
30
35
40
45
50
105
No. of operations, ×10
4
Max.
Min.
x
Contact resistance, mΩ