LKG1AF-24V-16

–1–
ASCTB198E 201604-T
ORDERING INFORMATION
TYPES
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
RATING
1. Coil data
1mm .039inch contact gap
1 Form A 10A/16A
power relays
LK-G RELAYS
Contact arrangement Nominal coil voltage
Part No.
10A, 1 mm contact gap type 16A, 1 mm contact gap type 16 A standard type
1 Form A
5V DC LKG1aF-5V-10-1 LKG1aF-5V-16-1 LKG1aF-5V-16
9V DC LKG1aF-9V-10-1 LKG1aF-9V-16-1 LKG1aF-9V-16
12V DC LKG1aF-12V-10-1 LKG1aF-12V-16-1 LKG1aF-12V-16
24V DC LKG1aF-24V-10-1 LKG1aF-24V-16-1 LKG1aF-24V-16
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5V DC
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
106.4mA 47Ω
530mW
6.5V DC
9V DC 58.8mA 153Ω 11.7V DC
12V DC 44.2mA 272Ω 15.6V DC
24V DC 22.1mA 1,087Ω 31.2V DC
Protective construction: Flux-resistant
type
RoHS compliant
FEATURES
1. Contact gap: 1 mm .039 inch
2. Wide lineup of 3 types available
1) 10A, 1 mm .039 inch contact gap type
2) 16A, 1 mm .039 inch contact gap type
3) 16 A standard type
3. High inrush current capability (TV-5
approved)
4. Long insulation distance
1) Creepage distance and clearances
between contact and coil: Min. 6 mm
.236 inch (In compliance with IEC60065)
2) Surge withstand voltage between
contact and coil: 10,000 V
TYPICAL APPLICATIONS
1. Audio visual equipment
2. HA equipment
3. Home appliances
4. Office equipment
LK-G relay
LKG 1a F
Protective construction
F: Flux-resistant type
Contact capacity
10: 10A
16: 16A
Contact gap
Nil: Standard
1: 1 mm .039 inch
Contact arrangement
1a: 1 Form A
Nominal coil voltage (DC)
5V, 9V, 12V, 24V
Note: Certified by UL/C-UL, TÜV
LK-G
–2–
ASCTB198E 201604-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item
Specifications
10A, 1 mm .039 inch contact
gap type
16A, 1 mm .039 inch contact
gap type
16 A standard type
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 10A 277V AC 16A 277V AC
Max. switching power (resistive load) 2,770VA 4,432VA
Max. switching voltage 277V AC 277V AC
Max. switching current 10A (AC) 16A (AC)
Min. switching capacity (reference value)*
1
100mA 5V DC
Electrical
characteristics
Contact gap Min. 1 mm .039 inch
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 20 ms (excluding contact bounce time.) (with diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 2×10
6
(at 180 times/min.)
Electrical
Min. 10
5
(at 6 times/min.)
(with diode)
Min. 5×10
4
(at 6 times/min.)
(with diode)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Air pressure: 86 to 106 kPa
Max. operating speed 6 times/min. (at rated load)
Unit weight Approx. 12 g .42 oz
1. Max. switching power (AC resistive load) 2. Ambient temperature characteristics and coil
applied voltage
100
10
1
0 10 100
16A type
10A type
Contact voltage, V
Contact current, A
0
220
180
140
100
60
0 1020304050607080
Carrying current: 10A
Carrying current:
16A
Coil & contact
no carrying current
Ambient temperature, °C
Coil applied voltage, %V
Pick-up voltage
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C 239°F
3-(1). Electrical life test (10A type)
Sample: LKG1aF-12V-10-1, 6 pcs.
Operation frequency: 6 times/min.
(ON/OFF = 1s: 9s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
277V AC
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
2
4
6
8
10
12
510
Drop-out voltage
Pick-up voltage
No. of operations, ×10
4
Pick-up and drop-out voltage, V
Max.
Min.
x
Max.
Min.
x
0
0
5
10
15
20
25
30
35
40
45
50
105
No. of operations, ×10
4
Max.
Min.
x
Contact resistance, mΩ
LK-G
–3–
ASCTB198E 201604-T
3-(2). Electrical life test (16A type)
DIMENSIONS (mm inch)
SAFETY STANDARDS
* 1 mm Contact GAP type only (for standard GAP type, 16A 30V DC (0ms) 5×10
4
)
NOTES
Item
UL/C-UL (Recognized) TÜV (Certified) TV rating (UL/C-UL)
File No. Contact rating Cycles File No. Contact rating Cycles File No. Contact rating
10A type
E43149 10A 277V AC General use 10
5
B 12 09 13461 333 10A 250V AC (cos
φ
=1.0) 10
5
E43149 TV-5
10A 40V DC Resistive 10
5
10A 30V DC (0ms) 10
5
5A 30V DC Resistive 10
5
——
16A type
E43149 16A 125V AC General use 10
5
B 12 09 13461 333 16A 250V AC (cos
φ
=1.0) 10
5
E43149 TV-5
10A 40V DC Resistive 10
5
16A 30V DC (0ms) 10
5
*—
5A 30V DC Resistive 10
5
——
Sample: LKG1aF-12V-16-1, 6 pcs.
Operation frequency: 6 times/min.
(ON/OFF = 1s: 9s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
277V AC
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
2
4
6
8
10
12
5
Drop-out voltage
Pick-up voltage
No. of operations, ×10
4
Pick-up and drop-out voltage, V
Max.
Min.
x
Max.
Min.
x
0
0
5
10
15
20
25
30
35
40
45
50
5
No. of operations, ×10
4
Max.
Min.
x
Contact resistance, mΩ
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
0.5 dia.
.020 dia.
0.3
.012
1.65
.065
Max. 24
Max. .945
0.4
.016
16.5
.650
20
.787
Max. 11
Max. .433
7.5
.295
1.0
.039
4
.157
0.5
.020
Max. 25
Max. .984
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
16.5
.650
20
.787
2-.035 dia.
2-0.9 dia.
2-.051 dia.
2-1.3 dia.
7.5
.295
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.

LKG1AF-24V-16

Mfr. #:
Manufacturer:
Panasonic
Description:
RELAY GEN PURPOSE SPST 16A 24V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: