TPP 30-J Series, 30 Watt
www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input voltage range – AC range (universal input) 85 – 264 VAC
(derating of 4 %/V below 90 VAC input required)
– DC range 120 – 370 VDC
Input frequency 47 – 63 Hz
Input current at full load – at 115 VAC / 230 VAC 0.8 A max. / 0.4 A max.
Input protection T1.6 A/250 VAC (internal fuse)
Input inrush current – at 230 VAC 40 A max.
Zero load power consumption 0.04 W typ. (acc. ErP directive)
Output Specifications
Voltage set accuracy ±1%
Regulation – Input variation (Vin min. to Vin max.) 0.2% max.
– Load variation (0 to 100%) 3.3 & 5.0 Vout models: 0.7% max.
other output models: 0.5% max.
Minimum load not required
Temperature coefficient ±0.02%/K
Hold-up time – at 115 VAC 16 ms typ.
Start-up time 1500 ms max.
Rise time 40 ms typ.
Ripple and noise 3.3, 5.0 & 9.0 Vout models: 50 mVp-p typ.
w. cap. 10F/25V 1206 X7R MLCC
(20 MHz Bandwidth) 12, 15, 24 & 36 Vout models: 50 mVp-p typ.
w. cap. 1F/50V 1206 X7R MLCC
48 Vout model: 50 mVp-p typ.
w. cap. 0.1F/100V 1206 X7R MLCC
Transient response – Peak deviation (25% load step change) 3% max.
– Recovery time 500 s typ.
Overvoltage protection 125 – 140% of nominal Vout
Current limitation at 140% Iout typ.
Short circuit protection continuous (automatic recovery), hiccup
Capacitive load 3.3 Vout model: 10‘000 F max.
5 Vout model: 12‘000 F max.
9 Vout model: 3‘720 F max.
12 Vout model: 2‘085 F max.
15 Vout model: 1‘350 F max.
24 Vout model: 520 F max.
36 Vout model: 235 F max.
48 Vout model: 130 F max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Storage –40°C to +100°C
Output power derating – Temperature 3.3, 5 & 9 Vout models: 2.25 %/K above +60°C
other output models: 3.6 %/K above +75°C
– Low input voltage 4.0 %/V below 90 VAC
Humidity (non condensing) 5 – 95 % rel. H max.
Isolation voltage – Input / Output (60 s) 4000 VAC (2 MOPP insulation)
– Input / Floating (60 s) 1500 VAC (1 MOPP insulation)
– Output / Floating (60 s) 1500 VAC (1 MOPP insulation)
Leakage current (at 264 VAC) 100 A max.
Isolation resistance (at 500 VDC) 100 MOhm min.
Altitude during operation 5000 m max.