2833741

Phoenix Contact page 1 of 5
Universal Modular System
The 27 mm*) (1.063 in.) wide PR2 relay base range
is a modular system consisting of PR2-B... relay bases,
robust REL-IR... electromechanical industrial relays
with DPDT and 4PDT contacts, and a comprehensive
range of accessories. These include:
Plug-in input/interference suppression modules
Relay retaining bracket with labeling field and eject
function
Labels
Continuous jumpers
Depending on the application, complete coupling
relays can be created, which are optimized in terms of
cost and function.
Base Versions
The relay bases are available in three versions - the
at 2/2 level PR2-BSC2 type with screw connections,
and the "logical" 1/3 level PR2-BSC3 with screw
connections and PR2-BSP3 with spring-cage
connections. The logical versions have coil and contact
connections that are located opposite one another and
thus meet the requirements of modern control cabinet
concepts with clear isolation of control signals and
load.
Robust, Cost-Effective Industrial Relays
Industrial relays are used in many sectors of industry
due to their robust structure, which has 2.6 mm
(0.102 in.) at pins. The main features of the REL/IR...
series include the fully automated manufacture of
products in conjunction with the high degree of product
stability and global availability. The following versions
are available:
With two 10 A 2PDT contacts
With four 5 A 4PDT contacts
In all popular AC and DC coil voltages
Considerably wider and more expensive miniature
contactors can thus be replaced cost-effectively in
many applications without adversely affecting machine
or system operation. All industrial relays have the
following standard features:
Manual test key (AC coil = red key, DC coil = blue
key)
Mechanical switch setting display
LED status indicators
Free-wheeling diode (only DC types)
Power contacts with solid gold coating (only types
with 4PDT contacts)
*) Spring-cage version is 31 mm (1.220 in.) wide
11
11
22
22
33
33
b
a
c
PR2 Relay Base for:
– Industrial DPDT or 4PDT Relays
Phoenix Contact GmbH & Co. KG • 32825 Blomberg, Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local Contact: www.phoenixcontact.com/salesnetwork
123
PR2-BSC2... PR2-BSC3... PR2-BSP3...
Nominal voltage U
1
)
Nominal current I
1
)
300 V AC
12 A
300 V AC
12 A
300 V AC
10 A
Conductor cross
section
– Solid
– Flexible
American Wire Gauge
2 x 2.5 mm
2
2 x 2.5 mm
2
2 x 14 AWG
2 x 2.5 mm
2
2 x 2.5 mm
2
2 x 14 AWG
2 x 1.5 mm
2
2 x 1.5 mm
2
2 x 16 AWG
Connection type
Approvals
2
)
C A C A C A
Stripping length
Height (a) with
retaining bracket:
– EL2-P35
Depth (b)
Width (c)
84 mm
(3.307 in.)
75 mm
(2.953 in.)
27 mm
(1.063 in.)
86 mm
(3.386 in.)
78.5 mm
(3.091 in.)
27 mm
(1.063 in.)
84 mm
(3.307 in.)
95 mm
(3.740 in.)
31 mm
(1.220 in.)
Ambient temperature -25°C...+85°C
(-13°F...
+185°F)
-25°C...+85°C
(-13°F...
+185°F)
-25°C...+85°C
(-13°F...
+185°F)
1
) The maximum electrical data is relay dependent.
2
) Details on request.
3
)Two spring-cage connections per terminal point.
M 3 M 3
3
)
8 mm (0.31 in.)
8 mm (0.31 in.)
12 mm (0.47 in.)
Phoenix Contact page 2 of 5
Description
Type Order No.
Pcs
.
Pkt.
PR2-B relay base
, for REL-IR Industrial
DPDT or 4PDT Relays, 2/2 level version,
screw connections, optional connection of
input/interference suppression module,
for mounting on
33
33
,
including MP2 mar-
kers, 10 pcs. per pack
PR2-BSC2/4x21 28 33 56 3
10
PR2-B relay base
, for REL-IR Industrial
DPDT or 4PDT Relays, 1/3 level version,
screw connections, optional connection of
input/interference suppression module,
for mounting on
33
33
,
including MP2 markers,
10 pcs. per pack
PR2-BSC3/4x21 28 33 57 6
10
PR2-B relay base
, for REL-IR Industrial
DPDT or 4PDT Relays, 1/3 level version,
spring-cage connections, optional connection
of input/interference suppression module,
for mounting on
33
33
,
including MP1 mar-
kers, 10 pcs. per pack
PR2-BSP3/4x21 28 33 58 9
10
Relay retaining bracket
, with eject function
and integrated device marking area
(8 x 25 mm [0.315 x 0.984 in.]), suitable for
PR2 relay base:
–For 35 mm (1.378 in.) high industrial relays
EL2-P35 28 33 59 2
10
Device marker
:
– Suitable for PR2-BSP,
6 x 15 mm (0.236 x 0.591 in.) marking area
– Suitable for PR2-BSC,
9 x 25 mm (0.354 x 0.984 in.) marking area
MP1
MP2
28 33 63 1
28 33 64 4
10
10
Plug-in module,
for mounting on PR1 and
PR2, with free-wheeling diode and yellow
LED, polarity:
A1 +, A2 –
Input voltage:
– 12 - 24 V DC ±20%
– 48 - 60 V DC ±20%
– 110 V DC ±20%
LDP-12-24DC
1
)
LDP-48-60DC
1
)
LDP-110DC
1
)
28 33 65 7
28 33 66 0
28 33 67 3
10
10
10
Plug-in module,
for mounting on PR1 and
PR2, with free-wheeling diode and yellow
LED, polarity:
A1 –, A2 +
(Japanese standard)
Input voltage:
– 12 - 24 V DC ±20%
– 48 - 60 V DC ±20%
– 110 V DC ±20%
LDM-12-24DC
1
)
LDM-48-60DC
1
)
LDM-110DC
1
)
28 33 68 6
28 33 69 9
28 33 70 9
10
10
10
Plug-in module,
for mounting on PR1 and
PR2, with varistor and yellow LED, input
voltage:
– 12 - 24 V AC/DC ±20%
– 48 - 60 V AC/DC ±20%
– 120 - 230 V AC/110 V DC ±20%
LV-12-24UC
(30 V varistor)
LV-48-60UC
(75 V varistor)
LV-120-230AC/110 DC
(275 V varistor)
28 33 71 2
28 33 72 5
28 33 73 8
10
10
10
Plug-in module,
for mounting on PR1 and
PR2, with varistor
Input voltage:
– 12 - 24 V AC/DC ±20%
– 48 - 60 V AC/DC ±20%
– 120 - 230 V AC/DC ±20%
V-12-24UC
(30 V varistor)
V-48-60UC
(75 V varistor)
V-120-230UC
(275 V varistor)
28 33 86 4
28 33 87 7
28 33 88 0
10
10
10
Plug-in module,
for mounting on PR1 and
PR2, with RC element
Input voltage:
– 12 - 24 V AC/DC ±20%
– 48 - 60 V AC/DC ±20%
– 120 - 230 V AC/DC ±20%
RC-12-24UC
(220 nF/100
)
RC-48-60UC
(220 nF/220
)
RC-120-230UC
(100 nF/470
)
28 33 74 1
28 33 75 4
28 33 76 7
10
10
10
Wire jumper
, 50-pos., can be separated,
maximum jumpering distance of 60 mm
(2.36 in.), 0.5 mm
2
(20 AWG), insulation:
– Blue
– Black
– Gray
DB 50-90 BU
DB 50-90 BK
DB 50-90 GY
28 21 18 0
28 20 91 6
28 20 92 9
1
1
1
1
)Might not be required, as LED and free-
wheeling diode are already integrated in
the REL-IR/LD... relays.
- A 2 + A 1
- A 1+ A 2
A 2 A 1
A 2 A 1
A 2 A 1
PR2 Relay Base for Industrial DPDT or 4PDT Relays
Phoenix Contact page 3 of 5
Description
Type Order No.
Pcs
.
Pkt.
Plug-in industrial relays
1
)
with power
contacts, DPDT contacts
, test key, status
LED, free-wheeling diode, mechanical
switch setting display, polarity:
A1 +, A2 –
Coil voltage:
– 12 V DC
– 24 V DC
– 48 V DC
– 110 V DC
Plug-in industrial relays
1
)
with power
contacts, DPDT contacts
, test key, status
LED, free-wheeling diode, mechanical
switch setting display, polarity:
A1 –, A2 +
(Japanese standard)
Coil voltage:
– 12 V DC
– 24 V DC
– 48 V DC
– 110 V DC
Plug-in industrial relays
1
)
with power
contacts, DPDT contacts
, test key, status
LED, mechanical switch setting display
Coil voltage:
– 24 V AC
– 120 V AC
– 230 V AC
REL-IR/LDP-12DC/2x21
REL-IR/LDP-24DC/2x21
REL-IR/LDP-48DC/2x21
REL-IR/LDP-110DC/2x21
REL-IR/LDM-12DC/2x21
REL-IR/LDM-24DC/2x21
REL-IR/LDM-48DC/2x21
REL-IR/LDM-110DC/2x21
REL-IR/L-24AC/2x21
REL-IR/L-120AC/2x21
REL-IR/L-230AC/2x21
28 34 01 2
28 34 02 5
28 34 03 8
28 34 04 1
28 34 15 1
28 34 16 4
28 34 17 7
28 34 18 0
28 34 05 4
28 34 06 7
28 34 07 0
10
10
10
10
10
10
10
10
10
10
10
Technical Data
Coil Side DC Coils
Nominal input voltage U
N
Permissible range (with reference to U
N
)
Typical input current at U
N
Typical response time at U
N
Typical release time at U
N
DC coil resistance at 20°C (68°F)
12 V DC 24 V DC 48 V DC 110 V DC
See diagram on page 5
75 mA 38 mA 19 mA 10 mA
13 ms 13 ms 13 ms 13 ms
5 ms 5 ms 5 ms 5 ms
160
±
15% 630
±
15% 2560
±
15% 11100
±
15%
Coil Side AC Coils (50 Hz/60 Hz)
Nominal input voltage U
N
Permissible range (with reference to U
N
)
Typical input current at U
N
(50 Hz/60 Hz)
Typical response time at U
N
(depending on phase relation)
Typical release time at U
N
(depending on phase relation)
DC coil resistance at 20°C (68°F)
24 V AC 120 V AC 230 V AC
See diagram on page 5
54 mA/46 mA 11 mA/9 mA 5 mA/4 mA
4 - 10 ms 4 - 10 ms 4 - 10 ms
3 - 12 ms 3 - 12 ms 3 - 12 ms
180
±
15% 4430
±
15% 18790
±
15%
Contact Side
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
Minimum switching current
Maximum shutdown power (ohmic load)
Minimum switching power
250 V AC
REL-IR...2x21
Single contact, 2 PDT contacts
Ag
250 V AC/125 V DC
5 V
10 A
20 A (15 ms)
1 mA
2500 VA
For additional data, see diagram on page 5
5 mW
General Data
Test voltage: Winding/contact
Contact/contact
Ambient temperature
Nominal operating mode
Mechanical service life
Electrical service life
Standards/specications
Approvals
Mounting position/mounting
2 kV, 50 Hz, 1 minute
2 kV, 50 Hz, 1 minute
-55°C to +70°C (-67°F to +158°F)
100% ED
5 x 10
7
cycles
See diagram on page 5
IEC 60 664/IEC 60 664 A/DIN VDE 0110,
degree of pollution 2, Surge Voltage Category II
UL; CSA; VDE
Any/can be mounted without spacing
1
)Further voltage versions, lockable test key, etc. on request.
2 2
A 1
2 1 2 4
1 21 1 1 4
A 2
Representation without
LED and free-wheeling
diode.
Contacts 21, 22, and 24
are led to relay base
connections 41, 42, and
44.
Plug-In Industrial Relays With DPDT Contacts, Suitable for PR2 Relay Base

2833741

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Relay Sockets & Hardware RC-12-24UC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union