General Description
The MAX8600/MAX8601 single-/dual-input linear bat-
tery chargers safely charge single-cell Li+ batteries.
The charging rate is optimized to accommodate the
thermal characteristics of a given application. There is
no need to reduce the maximum charge current or
worst-case charger power dissipation. Charging is opti-
mized for Li+ cells using a control algorithm that
includes low-battery precharging, voltage and current-
limited fast-charging, and top-off charging, while con-
tinuously monitoring the battery for overvoltage,
over/undertemperature, and charging time. The charg-
er timeout protection is programmable. The charger
status is indicated by three open-drain outputs.
The MAX8601 automatically selects between either a
USB or AC adapter input source. The AC adapter
charge current is programmable, while USB charge
current is set not to exceed either 100mA or 500mA,
depending on the USEL input. The MAX8600 is a sin-
gle-input charger with no USB source input.
The MAX8600/MAX8601 are available in a 3mm x 3mm
power-enhanced TDFN package.
Applications
Cell Phones Portable Media Players
Digital Cameras MP3 Players
PDAs Wireless Appliances
Features
Single- (MAX8600) or Dual- (MAX8601) Input Li+
Charger
Up to 1A Programmable Fast-Charge
100mA/500mA USB Select Input (MAX8601)
±5% Fast-Charge Current-Limit Accuracy
14V Input Overvoltage Protection
Programmable On-Chip Charge Timers
Battery Thermistor Input
Charger-Status Outputs
Thermally Optimized Charge Rate
14-Pin, 3mm x 3mm TDFN Package
MAX8600/MAX8601
Single-/Dual-Input 1-Cell Li+ Chargers with
OVP Protection and Programmable Charge Timer
________________________________________________________________ Maxim Integrated Products 1
19-3565; Rev 3; 12/08
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
EVALUATION KIT
AVAILABLE
Ordering Information
PART
TEMP
RANGE
PIN-PACKAGE
TOP
MARK
MAX8600ETD+
-40°C to
+85°C
14 TDFN-EP* 3mm x
3mm (T1433-2)
ABB
MAX8601ETD+
-40°C to
+85°C
14 TDFN-EP* 3mm x
3mm (T1433-2)
AAC
Pin Configurations continued at end of data sheet.
BAT
Li+
CT
THM
AC
ADAPTER
USB
PORT
GND
USB
EN
OFF
ON
FLT
V
LOGIC
CHARGE
STATUS
DC
SETI
USEL
POK
CHG
MAX8601
500mA
100mA
Typical Operating Circuit
8
9
10
11
12
13
14
7
6
5
4
3
2
1
MAX8600
TDFN
TOP VIEW
SETI
BAT
THM
GND
CT
N.C.
N.C.
FLT
DC
DC
CHG
POK
N.C.
EN
+
Pin Configurations
*EP = Exposed pad.
+Denotes a lead(Pb)-free/RoHS-compliant package.
MAX8600/MAX8601
Single-/Dual-Input 1-Cell Li+ Chargers with
OVP Protection and Programmable Charge Timer
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC, USB to GND ....................................................-0.3V to +16V
BAT, CT,
CHG, EN, FLT, SETI,
POK, THM, USEL to GND..................................-0.3V to +6.0V
Continuous Power Dissipation (T
A
= +70°C)
14-Pin TDFN 3mm x 3mm Multilayer PCB
(derate 24.4mW/°C above +70°C) ........................ 1951.2mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
ELECTRICAL CHARACTERISTICS
(V
DC
= V
USB
= 5V, V
BAT
= 4V, V
EN
= 0V, R
SETI
= 2kΩ, C
CT
= 0.068µF, T
A
= -40°C to +85°C, unless otherwise noted. Typical values
are at T
A
= +25°C. Note 1)
PARAMETER CONDITIONS
MIN TYP MAX UNITS
DC OR USB (Note 2)
Input Voltage Range 014V
Input Operating Range (Note 3)
4.15 7.00
V
Input Undervoltage Threshold
Input rising, 500mV hysteresis (typ)
3.85
4.0
4.15
V
Input Overvoltage Threshold Input rising, 200mV hysteresis (typ) 7.2 7.5 7.8 V
Input Overvoltage Delay From overvoltage event to charger disabled
0.25
s
Input Supply Current I
BAT
= 0mA, R
THM
= 10kΩ
750 1200
µA
Shutdown Input Current V
EN
= 5V, T
A
= +25°C
275 435
µA
Input to BAT On-Resistance Input = 3.7V, V
BAT
= 3.6V 0.5 0.8 Ω
Input to BAT Dropout Voltage
Input falling, 200mV hysteresis (typ) 5 55
120
mV
BAT
T
A
= +25°C
4.179
4.2
4.221
BAT Regulation Voltage I
BAT
= 0mA
T
A
= -40°C to +85°C
4.166
4.2
4.234
V
BAT Restart Fast-Charge
Threshold
From BAT regulation voltage
-180 -150 -120
mV
R
SETI
= 1.5kΩ
950 1000 1050
R
SETI
= 2kΩ
727 750 773
R
SETI
= 5kΩ
280 300 320
DC Charging Current V
USB
= 0V
Prequal, R
SETI
= 2kΩ, V
BAT
= 2.5V 60 75 90
mA
V
USEL
= 5V
450 475 500
V
USEL
= 0V 80 95
100
USB Charging Current V
DC
= 0V
Prequal, R
SETI
= 2kΩ, V
BAT
= 2.5V 60 75 90
mA
Soft-Start Time Ramp time to fast-charge current 1.2 ms
BAT Prequal Threshold V
BAT
rising, 180mV hysteresis (typ) 2.9 3.0 3.1 V
BAT Leakage Current V
DC
= V
USB
= 0V, V
BAT
= 4.2V
0.001
A
SETI
R
SETI
Resistance Range Guaranteed by charging current 1.5 5.0 kΩ
MAX8600/MAX8601
Single-/Dual-Input 1-Cell Li+ Chargers with
OVP Protection and Programmable Charge Timer
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
DC
= V
USB
= 5V, V
BAT
= 4V, V
EN
= 0V, R
SETI
= 2kΩ, C
CT
= 0.068µF, T
A
= -40°C to +85°C, unless otherwise noted. Typical values
are at T
A
= +25°C. Note 1)
PARAMETER CONDITIONS
TYP
MAX
UNITS
EN, USEL
Rising 1.6
Logic Input Thresholds
Falling 0.4
V
T
A
= +25°C
0.001
1
Logic Input Leakage Current
V
EN
= V
USEL
= 0 to 5.5V
T
A
= +85°C
0.01
µA
POK, CHG, FLT
Logic Output Voltage, Low I
POK,
= I
CHG
= I
FLT
= 1mA 12
100
mV
T
A
= +25°C
0.001
1
Logic Output Leakage
Current, High
V
POK
= V
CHG
= V
FLT
= 5.5V,
V
DC
= V
USB
= 0V
T
A
= +85°C
0.01
µA
CHG
R
SETI
= 1.5kΩ 75
R
SETI
= 2kΩ
37.5 56.25 75.0
CHG/Top-Off Threshold
I
BAT
falling, battery is
charged
R
SETI
= 5kΩ
22.5
mA
THM
THM Pullup Resistance 10 kΩ
THM Resistance, Hot R
THM
falling, 420Ω hysteresis (typ)
3.72 3.94 4.13
kΩ
THM Resistance, Cold R
THM
rising, 2.7kΩ hysteresis (typ)
26.7 28.3 29.7
kΩ
THM Resistance, Disabled R
THM
falling, 230Ω hysteresis (typ)
274 309 337
Ω
CT
Timer Accuracy C
CT
= 0.068µF -20
+20
%
Prequal Time Limit From entering prequal to FLT low, V
BAT
< 3V
34.8
min
Charge Time Limit From entering fast-charge to FLT low, 3V < V
BAT
< 4.2V
334
min
Top-Off Time Limit From CHG high to charger disabled
34.8
min
THERMAL LOOP
Thermal-Limit Temperature
Juncti on tem p er atur e w hen the char g e cur r ent i s r ed uced ,
T
J
r i si ng
+100
°C
Thermal-Limit Gain
Reduction of I
BAT
for increase of T
J
, from V
DC
, R
SETI
= 1.5kΩ
5
%/°C
Note 1: Limits are 100% production tested at T
A
= +25°C. Limits over the operating temperature range are guaranteed by design
and characterization.
Note 2: Input refers to either DC or USB.
Note 3: Guaranteed by undervoltage- and overvoltage-threshold testing. For complete charging, the input voltage must be greater