CXA-L0605C-VSL

No. MATERIALS NAME
MATERIAL REMARK
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-L0605C-VxL
PAGENAME OF DRAWING DRAWING No.
Product Drawing CTR-3818-X
TSB-08-01-05(00) form-6(A4)
TDK-L
TDK-LTDK-L
TDK-Lambda
ambdaambda
ambda
QU
<The specifications may be changed without any notice.>
6
T
E
N
T
A
T
I
V
E
[4] Test circuit
Note.4-1.SW1(ON/OFF) Operation is as following;
SW1
a
b
Operation
Non operation
Non operationOpen
Operation of unit
V
Note4-2.Safety Function
1000:1
A
~
V
~
F
A
Digital Multiple Meter(ADVA NTEST R6451A or equivalent)
DC Current Meter(ADVANTEST R6451A or equivalent)
True RMS Meter(KEITHLEY 2001 or equivalent.)
High Frequency Current Mete r(KEITHLEY 2001 or equivalent)
High Voltage Probe (Tektronix P3000 or equivalent)
Frequency Countor(ADVANTE ST R6452A or equivalent)
1000:1
CN1-1
(Vin)
V
F
CN1-2
(GND)
CN1-3
(Vrmt)
CN1-4
(Vbr)
CN1-5
(NC)
Vbr=0V:Dimmingmax.
T1-1 T1-6
LCD module Connected chart (reference)
DC-AC inverter
V
LOW
V
HIGH
A
LCD module
Lamp
NC
lin
SW1
b
a
Vrmt 5V
Vin
4.755.25V
Vbr
0~3V
A
-
V
-
V
-
V
-
RL
A
CN2-1
(V
HIGH
)
CN2-3
(V
LOW
)
CXA-L0605-VJL
SM02(8.0)B-BHS-1-TB
(JST)
Iout
CXA-L0605-VSL
SM02B-BHSS-1-TB
(JST)
CN2-1
(V
HIGH
)
CN2-2
(V
LOW
)
Vrmt terminal circuit (Reference)
47.1kΩ
22kΩ
CN1-3
Vrmt
10kΩ
10kΩ
IC1
CN1-1
Vin
F
Vopen
Connect the High Frequency Current Meter to the Low-Voltage (VLOW) si de.
No. MATERIALS NAME
MATERIAL REMARK
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-L0605C-VxL
PAGENAME OF DRAWING DRAWING No.
Product Drawing CTR-3818-X
TSB-08-01-05(00) form-6(A4)
TDK-L
TDK-LTDK-L
TDK-Lambda
ambdaambda
ambda
QU
<The specifications may be changed without any notice.>
7
T
E
N
T
A
T
I
V
E
[5] Reliability test
Following test items are assured.
Items Conditions
-30°C 500h
-30°C 500h
Load cond.:TYP
8C 500h
8C 500h
Load cond.:TYP
Heat shock
Vibration
Shock
-30°C to 8C
30min.Each 100 Cycles
10~57Hz Amplitude 0.75mm or 9.8m/s
2
58~500Hz 9.8m/s
2
Sweep:11min
60min each axis X,Y,Z
980m/s
2
11ms
Harf-sine pulse
1 time each axis ±X,Y,Z
Judgement
Low Temp.
Non operational
Low Temp.operational
High Temp.
Non operational
High Temp.operational
Electrical and apperrance should be in the
spec.
Humidity
(Non operational)
6C 90~95%RH 500h
No. MATERIALS NAME
MATERIAL REMARK
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-L0605C-VxL
PAGENAME OF DRAWING DRAWING No.
Product Drawing CTR-3818-X
TSB-08-01-05(00) form-6(A4)
TDK-L
TDK-LTDK-L
TDK-Lambda
ambdaambda
ambda
QU
<The specifications may be changed without any notice.>
8
T
E
N
T
A
T
I
V
E
7-1.Test conditions
Unless otherwise specified, the temperature to be (25±15) and humidity to be (65±20) %RH.
7-2. Warranty
Warranty shall be for one year after delivery, and those products causing failure during the warranty period
and which failures are attributed to the manufa cturer's responsibility shall be replaced at no charge.
7-3.Oters
When any doubt arises about th is specification, it shall be discussed and decided upon between both parties.
Shipment inspection result sheet are subject to change without notice.
7 Others
[6] Packing and Marking
A shipping box is packaged to avoid from water or damage. Following items are printed on the box.
6-1.
6-2.
6-3.
TDK part No.
Manufacture
QTY.
CXA-L0605C-VxL
Tray
(25pcs)×8stack= 200pcs/box
(Cardboard)
Outer carton
(400mm:L)×(333mm:W)×(149mm:H)
Marking
  TDK Part No.
  Manufacture
  QTY.
 

CXA-L0605C-VSL

Mfr. #:
Manufacturer:
TDK
Description:
INVERTER 5V-INPUT 1600V-OUTPUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet