JTK3048S05

JTK30 Series
DC-DC Converter
xxx Series
www.xppower.com
1
Models & Ratings
Notes
1. Input currents measured at nominal input voltage.
2. Maximum capacitive load is per output.
3. Add suffix ‘-HK’ for optional heatsink.
Single and Dual Outputs
1” x 1” Footprint
-40 °C to +100 °C Operation
Full Load at 55 °C Ambient
1600 VDC Isolation
Output Trim ±10%
Remote On/Off
MTBF 370 kHrs
3 Year Warranty
D
imensions:
J
TK30:
1
.0 x 1.0 x 0.43” (25.4 x 25.0 x 10.9 mm)
30 Watts
M
e
ch
a
n
ica
l
De
ta
ils
Input
Voltage
Output
Voltage
Output
Current
Input Current
(1)
OVP setting Efficiency
Max.
capacitive load
(2)
Model Number
(3)
No Load Full Load
9-36 V
3.3 V 7.0 A 10 mA 1095 mA 3.9 V 88% 10000 µF JTK3024S3V3
5.0 V 6.0 A 10 mA 1405 mA 6.2 V 89% 7200 µF JTK3024S05
12.0 V 2.5 A 10 mA 1405 mA 15.0 V 89% 1200 µF JTK3024S12
15.0 V 2.0 A 10 mA 1375 mA 18.0 V 91% 1000 µF JTK3024S15
±12.0 V ±1.25 A 10 mA 1405 mA ±15.0 V 89% ±750 µF JTK3024D12
±15 V ±1.0 A 10 mA 1375 mA ±18.0 V 91% ±500 µF JTK3024D15
18-75 V
3.3 V 7.0 A 8 mA 540 mA 3.9 V 89% 10000 µF JTK3048S3V3
5 V 6.0 A 8 mA 695 mA 6.2 V 90% 7200 µF JTK3048S05
12 V 2.5 A 8 mA 695 mA 15.0 V 90% 1200 µF JTK3048S12
15 V 2.0 A 8 mA 680 mA 18.0 V 92% 1000 µF JTK3048S15
±12 V ±1.25 A 8 mA 695 mA ±15.0 V 90% ±750 µF JTK3048D12
±15 V ±1.0 A 8 mA 685 mA ±18.0 V 91% ±500 µF JTK3048D15
5
3
4
21
0.6
(15.24)
DIA
0.04
(1.0)
6
1.0
(25.4)
1.0 (25.4)
0.1
(2.54)
0.4
(10.16)
0.4
(10.16)
0.5
(0.02)
0.1
(2.54)
0.1
(2.54)
0.24
(6.0)
0.1
(2.54)
0.8
(20.32)
0.3
(7.62)
0.2
(5.08)
0.41
(10.4)
Top View
Bottom View
6
321
54
1.0 (25.4) 0.66 (16.8)
1.0
(25.4)
Dia
0.04
(1.0)
1. All dimensions are in inches (mm)
2. Weight: 0.042 lbs (19 g) approx.
3. Pin diameter: 0.04±0.002 (1.0±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
Notes
Pin Connections
Pin Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 Remote On/Off Remote On/Off
4 +Vout +Vout
5 Trim Common
6 -Vout -Vout
Optional Heatsink (-HK)
JTK30 Series
www.xppower.com
2
DC-DC Converter
Input
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
O
utput Voltage 3.3 30 VDC See Models and Ratings table
O
utput Trim ±10 % Single Output Versions
I
nitial Set Accuracy ±1 % At full load
Minimum Load 0%No minimum load required
L
ine Regulation ±0.5 % From minimum to maximum input at full load
Load Regulation 0.5/1.0 % From 0% to full load for single/dual output
Cross Regulation ±5 %
O
n dual output models, when one output is at 100% load
and other is varied from 25% load to full load
R
ipple & Noise 75/60 mV pk-pk
Single output with 10 µF/25 V X7R MLCC on output
D
ual output with 10 µF/25 V X7R MLCC on each output
measured using 20 MHz bandwidth
Overload Protection 170 %
Short Circuit Protection Trip and Restart (hiccup), with auto recovery
Maximum Capacitive Load See Models and Ratings table
Temperature Coefficient 0.02 %/ ˚C
Overvoltage Protection See Models and Ratings table
Remote On/Off
Output is on if remote on/off (pin 3) is open
Output turns off if remote on/off (pin 3) is low (<1.2 VDC)
C
haracteristic
M
inimum
T
ypical
M
aximum
U
nits
N
otes & Conditions
I
nput Voltage Range
9 36 VDC 24 V nominal
18 75 VDC 48 V nominal
I
nput Reflected Ripple Current 30 mA pk-pk Through 12 µH inductor and 47 µF capacitor
Input Surge
5
0 VDC for 100 ms 24 V models
1
00 VDC for 100 ms 48 V models
General
Characteristic Minimum Typical Maximum Units Notes & Conditions
Efficiency 90 % See Models and Ratings table
Isolation: Input to Output 1600 VDC
Isolation: Input to Case 1600 VDC
Switching Frequency 330 kHz
Isolation Resistance 10
9
Ω
Isolation Capacitance 2000
pF
Power Density 73 W/in
3
Mean Time Between Failure 370 kHrs MIL-HDBK-217F, +25 °C GB
Weight 0.042 (19.0) lb (g)
Environmental
Characteristic Minimum Typical Maximum Units Notes & Conditions
Operating Temperature -40 +100 °C
Derate from 100% load at +55 °C to 50% load at +80 °C
or from 100% load at 60 °C to 50% load at 85 °C with
optional heatsink
Storage Temperature -55 +125 °C
Case Temperature +105 °C
Humidity 95 %RH Non-condensing
Cooling Natural convection
JTK30 Series
www.xppower.com
DC-DC Converter
3
Mechanical Details
EMC: Immunity
P
henomenon
S
tandard
T
est Level
C
riteria
N
otes & Conditions
ESD Immunity EN61000-4-2 ±6 kV / ±8 kV A Contact Discharge / Air Discharge
R
adiated Immunity EN61000-4-3 20 Vrms A
E
FT/Burst EN61000-4-4 2 kV A External input filter required, see applications note
S
urge EN61000-4-5 2 kV A External input filter required, see applications note
Conducted Immunity EN61000-4-6 10 V rms A
Magnetic Fields EN61000-4-8 100 A/m A
EMC: Emissions
Phenomenon Standard Test Level Notes & Conditions
Conducted EN55032 Class A See Application Note
R
adiated EN55032 Class A
5
3
4
21
0.6
(15.24)
DIA
0.04
(1.0)
6
1.0
(25.4)
1.0 (25.4)
0
.1
(2.54)
0.4
(10.16)
0.4
(10.16)
0.5
(0.02)
0
.1
(2.54)
0.1
(2.54)
0.24
(6.0)
0.1
(2.54)
0.8
(20.32)
0.3
(7.62)
0.2
(5.08)
0.41
(
10.4)
Top View
Bottom View
6
321
54
1.0 (25.4) 0.66 (16.8)
1.0
(25.4)
Dia
0.04
(1.0)
1. All dimensions are in inches (mm)
2. Weight: 0.042 lbs (19 g) approx.
3. Pin diameter: 0.04±0.002 (1.0±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
Notes
Pin Connections
Pin Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 Remote On/Off Remote On/Off
4 +Vout +Vout
5 Trim Common
6 -Vout -Vout
Optional Heatsink (-HK)

JTK3048S05

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 5V 30W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union