AUIRS2301S
www.irf.com © 2009 International Rectifier
6
Static Electrical Characteristics
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj
≤125°C with bias conditions of V
BIAS
(V
CC
, V
BS
) = 15V. The V
IL,
V
IH
and I
IN
parameters are referenced to COM
and are applicable to the respective input leads: HIN and LIN. The V
O,
I
O
and R
on
parameters are referenced
to COM and are applicable to the respective output leads: HO and LO.
Symbol Definition Min Typ Max Units Test conditions
V
IH
Logic “1” input voltage 2.5 — —
V
IL
Logic “0” input voltage — — 0.8
V V
CC
= 10V to 20V
V
OH
High level output voltage, V
BIAS
-
V
O
— — 0.2
V
OL
Low level output voltage, V
O
— — 0.1
V I
O
= 2mA
I
LK
Offset supply leakage current — — 50 V
B
=
V
S
= 600V
I
QBS
Quiescent V
BS
supply current 60 160 260
I
QCC
Quiescent V
CC
supply current 60 160 260
V
IN
= 0V or 5V
I
IN+
Logic “1” input bias current — 5 20 V
IN
= 5V
I
IN-
Logic “0” input bias current — — 5
µA
V
IN
= 0V
V
CCUV+
V
BSUV+
V
CC
and V
BS
supply undervoltage positive
going threshold
3.3 4.1 5
V
CCUV-
V
BSUV-
V
CC
and V
BS
supply undervoltage negative
going threshold
3 3.8 4.7
V
CCUVH
V
BSUVH
Hysteresis 0.1 0.3 —
V
I
O+
Output high short circuit pulsed current — 200 —
V
O
= 0V,
PW ≤ 10µs
I
O-
Output low short circuit pulsed current — 350 —
mA
V
O
= 15V,
PW ≤ 10µs
Dynamic Electrical Characteristics
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj
≤125°C with bias conditions of
V
BIAS
(V
CC
, V
BS
) = 15 V, C
L
= 1000 pF.
Symbol Definition Min Typ Max Units Test conditions
t
on
Turn-on propagation delay — 220 300 V
S
= 0V
t
off
Turn-off propagation delay — 200 280
V
S
= 0V or 600V
MT Delay matching, HS & LS turn-on/off — 0 50
t
r
Turn-on rise time — 130 220
t
f
Turn-off fall time — 50 80
ns
V
S
= 0V