70W Constant Current Mode LED Driver
HLG-60H-C series
SPECIFICATION
MODEL
RATED CURRENT
CURRENT TOLERANCE
CURRENT RIPPLE
RATED POWER
CURRENT ADJ. RANGE
SET UP TIME
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.6
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A/AB-Type only (via built-in potentiometer)
750ms/115VAC, 500ms/230VAC
47 ~ 63Hz
<0.75mA / 277VAC
Compliance to EN55015, EN61000-3-2 Class C ( ) ; EN61000-3-3,GB17743 and GB17625.1, EAC TP TC 020@ load 60%≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020
10 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
℃
±℃ ℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
878.1K hrs min. Telcordia SR-332 (Bellcore) ; 338K hrs min. MIL-HDBK-217F (25 )℃
Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, re-power on to recover
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
±5%
5.0% max. @rated current
EMC IMMUNITY
EMC EMISSION
Note.6
COLD START 60A(t =275 s measured at 50% I ) at 230VAC;width peak Per NEMA 410
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
CONSTANT CURRENT REGION
Note.2
PACKING
NOTE
μ
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
8 units (circuit breaker of type B) / 13 units (circuit breaker of type C) at 230VAC
VOLTAGE RANGE Note.3
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
OUTPUT
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
INPUT
WORKING TEMP.
Tcase=-40 ~ +80 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP.
Tcase=+80℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the may lead to increase of the set up time.driver
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanentlydriver
connected to the mains.
7. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.℃
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
PF 0.9 / VAC, PF 0.96/2 VAC full load≧≧≧8 115 30 , PF 0.94/277VAC @
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20% (@ load 60% /115VAC, 230VAC; @ load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
210 ~ 350mA 420 ~ 700mA
HLG-60H-C350 HLG-60H-C700
350mA 700mA
70W 70W
100 ~ 200V 50 ~ 100V
91%
90.5%
0.69A / 115VAC 0.35A / 230VAC 0.29A / 277VAC
Hiccup mode, recovers automatically after fault condition is removed
230 ~ 250V
120 ~ 140V
UL8750, CSA C22.2 No. 250.0-08, independent,EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13 ,GB19510.1,GB19510.14
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
171*61.5*36.8 mm (L*W*H)
0.73Kg; 20pcs/15.6Kg/0.9CUFT
File Name:HLG-60H-C-SPEC 2018-05-29
, J61347-1,J61347-2-13 approvedEAC TP TC 004,IP65 or IP67