RW-0509D

ECONOLINE
DC/DC-Converter
with 3 year Warranty
RW-D
Input Voltage Range 2:1
Output Voltage Accuracy ±1% typ. / ±2% max.
Line Voltage Regulation 0.1% typ. / 0.2% max.
Load Voltage Regulation (10% to 100% full load) 0.2% typ. / 0.5% max.
Minimum Load 10%
(2)
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Operating Frequency 100KHz min. / 150kHz typ.
Efficiency at Full Load See above
No Load Power Consumption 250mW max.
Isolation Voltage (tested for 1 second) 3000VDC
(rated for 1 minute*) 1500VAC / 60Hz
Isolation Capacitance 20pF min. / 40pF typ. / 60pF max.
Isolation Resistance 1 GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
continued on next page
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
DIP24 Miniature (VDC) (VDC) (mA) % Load
(1)
RW-0505D 4.5 – 9 ±5 ±300 71 ±2200µF
RW-0509D 4.5 – 9 ±9 ±167 73 ±1000µF
RW-0512D 4.5 – 9 ±12 ±125 74 ±1000µF
RW-0515D 4.5 – 9 ±15 ±100 75 ±1000µF
RW-1205D 9 – 18 ±5 ±300 76 ±2200µF
RW-1209D 9 – 18 ±9 ±167 80 ±1000µF
RW-1212D 9 – 18 ±12 ±125 83 ±1000µF
RW-1215D 9 – 18 ±15 ±100 83 ±1000µF
RW-2405D 18 – 36 ±5 ±300 78 ±2200µF
RW-2409D 18 – 36 ±9 ±167 81 ±1000µF
RW-2412D 18 – 36 ±12 ±125 85 ±1000µF
RW-2415D 18 – 36 ±15 ±100 85 ±1000µF
RW-4805D 36 – 72 ±5 ±300 78 ±2200µF
RW-4809D 36 – 72 ±9 ±167 82 ±1000µF
RW-4812D 36 – 72 ±12 ±125 84 ±1000µF
RW-4815D 36 – 72 ±15 ±100 84 ±1000µF
3 Watt
DIP24
Low Profile
Regulated
Dual Output
DIP24 Low Profile Package
Dual Outputs from a Single Supply
2:1 Wide Range Voltage Input
3kVDC Isolation
UL94V-0 Package Material
Continuous Short Circuit Protection
Low profile 7mm Height
Approved for Medical Applications
Efficiency to 85%
Features
Regulated
Converters
Selection Guide
The RW_D series with 2:1 input voltage ranges and maximum height of 7,0 mm has been
designed for industrial automation and medical markets where a dual output rail needs to be
generated from a single rail source. The converters supply the full 3 Watts without additional
heat-sinks over the temperature range -40°C to +85°C.
Specifications (Core Operating Area)
Description
Output Power (%)
100
60
20
40
500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
90
2 W
1 W
3 W
95
Derating-Graph
(Ambient Temperature)
EN-60950-1 Certified
EN-60601-1 Certified
Refer to Application Notes
RoHS
2011/65/EU
6/6
*Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015 E-137www.recom-power.com
Specifications (Core Operating Area)
Package Style and Pinning (mm)
RW-xxxxD
Series
ECONOLINE
DC/DC-Converter
3.81
4.60
Bottom View
Top View
11
9
32
14
16
22
23
RECOM
RW-1205D
****
15.24
2.54
1.00
ø
+0.15/0
0.51
32.00
7.00
17.50
2.54
Recommended Footprint Details
24 PIN DIP Miniature Package Style
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Pin Dual
2 & 3 -Vin
9 & 16 Com
11 -Vout
14 +Vout
22 & 23 +Vin
NC = No Connection
Storage Temperature Range -55°C to +125°C
Case Material Non-Conductive Black Plastic
Potting Material Epoxy ( UL94V-0 )
Relative Humidity 95% RH
Package Weight 7.7g
Packing Quantity 15pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1636 x 10
3
hours
(+85°C) using MIL-HDBK 217F 303 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + A11:2009+A1:2010+A12:2011
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment
}
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2415
4815
RW-xx15D
Detailed Information see
Application Notes chapter "MTBF"
RW-D
Typical Performance
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RW-D series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 www.recom-power.comE-138

RW-0509D

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 3W DC/DC MIN 3kV REG 2:1 4.5-9Vin +/-9out
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: