HP
SPECIFICATIONS (at 20
°
C 68
°
F)
LIFE DATA
Contact rating and expected life For AC load type
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
10 AMP POWER RELAY
HP RELAYS
Voltage 125 V AC 250 V AC
Expected life
(min. operations)
Electrical
life
Load Resistive (cos
ϕ
]
1) Inductive (cos
ϕ
]
0.4) Resistive (cos
ϕ
]
1) Inductive (cos
ϕ
]
0.4)
Current
10 A 7.5 A 2
×
10
5
10 A 7.5 A 7.5 A 5 A 5
×
10
5
5 A3 A3 A2 A1
×
10
6
1A 0.7 A 0.6 A 0.4 A 2
×
10
6
Mechanical life 1
×
10
7
VDE
2c, 3c
mm inch
25
.984
36
1.417
44.5
1.752
FEATURES
• Interchangeable with existing models
• Long life and high reliability
• High contact capacity up to 10 A 250 V AC
• Available with plug-in/solder and quick-connect terminals
Contacts
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specications will vary with foreign standards certication ratings.
*
1
Measurement at same location as initial breakdown voltage section
*
2
Detection current; 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Characteristics (at 60 Hz, 20°C 68°F)
Arrangement 2 Form C 3 Form C 4 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
15 m
Contact material Silver
Silver
alloy
Rating
Nominal switching
capacity
10 A 250 V AC (resistive)
Min. switching capacity
#1
100 mA, 5 V DC
2 Form C 3 Form C 4 Form C
Maximum operating speed 20 cpm
Initial insulation resistance*
1
more than 100 M at 500 V DC
Breakdown
voltage*
2
Between open
contacts
1,000
Vrms
2,000
Vrms
1,000
Vrms
Between contact sets
1,500
Vrms
2,000
Vrms
1,500
Vrms
Between contact and
coil
1,500
Vrms
2,000
Vrms
1,500
Vrms
Operate time*
3
(at nominal voltage)
Max.
25 ms
Max. 30 ms
Release time (without diode)*
3
(at nominal voltage)
Max.
25 ms
Max. 30 ms
Temperature rise Max. 65°C
Shock resistance
Functional*
4
98 m/s
2
{10 G}
Destructive*
5
980 m/s
2
{100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at 1 mm double amplitude
Destructive
10 to 55 Hz
at 2 mm double amplitude
Conditions for
operation, transport
and storage*
7
(Not freezing and
condensing at low
temperature)
Ambient
temp.
50°C to +40°C
58°F to +104°F
Humidity 5 to 85% R.H.
Unit weight
Approx.
60g
2.12 oz
Approx.
100g
3.53 oz
Approx.
125g
4.41 oz
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HP
Contact rating and expected life For DC load type
TYPICAL APPLICATIONS
ORDERING INFORMATION
TYPES AND COIL DATA
1. Standard plug-in terminal type (without lamp wired)
DC TYPES at 20
°
C 68
°
F
Voltage 24 V DC 125 V DC
Expected life
(min. operations)
Electrical
life
Load Resistive (cos
ϕ
]
1) Inductive (cos
ϕ
]
0.4) Resistive (cos
ϕ
]
1) Inductive (cos
ϕ
]
0.4)
Current
7 A ——2
×
10
5
7.5 A 5 A 0.5 A 0.4 A 5
×
10
5
5 A 3 A 0.3 A 0.2 A 1
×
10
6
1A 0.6 A 0.1 A 0.06 A 2
×
10
6
Mechanical life 1
×
10
7
Type Part No.
Nominal coil
voltage, V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage, V DC
Coil
resistance,
(
±
10%)
Nominal coil
current, mA
Nominal
operating
power, W
2 Form C
HP2-DC6V 6 4.8 0.9 6.6 25 240 1.5
HP2-DC12V 12 9.6 1.8 13.2 110 109 1.3
HP2-DC24V 24 19.2 3.6 26.4 440 54.5 1.3
HP2-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3
HP2-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C
HP3-DC6V 6 4.8 0.9 6.6 24 250 1.5
HP3-DC12V 12 9.6 1.8 13.2 100 120 1.4
HP3-DC24V 24 19.2 3.6 26.4 400 60 1.4
HP3-DC48V 48 38.4 7.2 52.8 1,560 31 1.5
HP3-DC110V 110 88 16.5 121 7,450 14.9 1.6
4 Form C
HP4-DC6V 6 4.8 0.9 6.6 22 273 1.6
HP4-DC12V 12 9.6 1.8 13.2 95 127 1.5
HP4-DC24V 24 19.2 3.6 26.4 380 63 1.5
HP4-DC48V 48 38.4 7.2 52.8 1,500 32 1.5
HP4-DC110V 110 88 16.5 121 7,000 15.7 1.7
Life curve
Notes:
1. For DC inductive loads, use an arc
suppressing circuit.
2. When used under a DC load operating at
high repetition rate with considerable arcing,
corrosion of the contacts and/or the contact
blades is likely to occur. When using the relay
under conditions of high temperature, humidity
or high repetition rate, it is suggested that the
relay cover be removed to facilitate extended
operation.
10
0
100
200
300
400
500
600
700
800
900
1,000
Load current, A
Operations, ×10
4
125 V AC
cos
ϕ = 1
5
2
5
0
V
A
C
c
o
s
ϕ
=
1
Mechanical life
more than 10,000,000
operations
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
Industrial machinery
Machine tool
Food processing packing machines
Ofce equipment
Coin operate devices
Home appliances
Transportation
Communication and measuring devices
Amusement devices
Ex. HP 3
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
(Notes) 1. For UL/CSA or VDE recognized types, add suffix UL/CSA or VDE (HP2-TM type VDE application under way)
2. Standard packing Carton: 50 pcs. Case: 200 pcs.
3. UL/CSA approved type is standard.
Nil: Standard plug-in terminal
M: Direct mounting (3 Form C only)
TM: Top mounting (2 Form C only)
L: Lamp wired, standard plug-in terminal
AC 6, 12, 24, 48,
115, 220, 240 V
DC 6, 12, 24, 48,
110 V
Terminal Coil voltage
M AC240V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HP
AC TYPE (50/60 Hz) at 60 Hz, 20
°
C 68
°
F
NOTES
2. Standard plug-in terminal type (with lamp wired)
DC TYPES at 20
°
C 68
°
F
Type Part No.
Nominal coil
voltage, V AC
Pick-up
voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage, V AC
Inductance,
H
Nominal coil
current, mA
Nominal
operating
power, VA
2 Form C
HP2-AC6V 6 4.8 1.8 6.6 0.049 310 1.9
HP2-AC12V 12 9.6 3.6 13.2 0.190 160 1.9
HP2-AC24V 24 19.2 7.2 26.4 0.776 78 1.9
HP2-AC48V 48 38.4 14.4 52.8 3.106 39 1.9
HP2-AC115V 115 92 34.5 126.5 15.83 18 2.1
HP2-AC220V 220 176 66 242 57.90 9.5 2.1
HP2-AC240V 240 192 72 264 66.26 9.0 2.2
3 Form C
HP3-AC6V 6 4.8 1.8 6.6 0.030 520 3.1
HP3-AC12V 12 9.6 3.6 13.2 0.119 260 3.1
HP3-AC24V 24 19.2 7.2 26.4 0.475 130 3.1
HP3-AC48V 48 38.4 14.4 52.8 1.899 65 3.1
HP3-AC115V 115 92 34.5 126.5 10.36 28.5 3.3
HP3-AC220V 220 176 66 242 39.32 14.2 3.1
HP3-AC240V 240 192 72 264 44.05 13.9 3.3
4 Form C
HP4-AC6V 6 4.8 1.8 6.6 0.019 800 4.8
HP4-AC12V 12 9.6 3.6 13.2 0.077 400 4.8
HP4-AC24V 24 19.2 7.2 26.4 0.309 200 4.8
HP4-AC48V 48 38.4 14.4 52.8 1.292 95 4.6
HP4-AC115V 115 92 34.5 126.5 6.953 42 4.8
HP4-AC220V 220 176 66 242 26.57 21 4.6
HP4-AC240V 240 192 72 264 29.75 20.5 4.9
Type Part No.
Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage,
V DC
Coil
resistance,
(
±
10%)
Nominal coil
current,
mA
Nominal
operating
power,
W
2 Form C
LED
HP2-L-DC6V 6 4.8 0.9 6.6 25 240 1.5
HP2-L-DC12V 12 9.6 1.8 13.2 110 109 1.3
HP2-L-DC24V 24 19.2 3.6 26.4 440 54.5 1.3
HP2-L-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3
Neon lamp HP2-L-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C
LED
HP3-L-DC6V 6 4.8 0.9 6.6 24 250 1.5
HP3-L-DC12V 12 9.6 1.8 13.2 100 120 1.4
HP3-L-DC24V 24 19.2 3.6 26.4 400 60 1.4
HP3-L-DC48V 48 38.4 7.2 52.8 1,560 31 1.5
Neon lamp HP3-L-DC110V 110 88 16.5 121 7,450 14.9 1.6
4 Form C
LED
HP4-L-DC6V 6 4.8 0.9 6.6 22 273 1.6
HP4-L-DC12V 12 9.6 1.8 13.2 95 127 1.5
HP4-L-DC24V 24 19.2 3.6 26.4 380 63 1.5
HP4-L-DC48V 48 38.4 7.2 52.8 1,500 32 1.5
Neon lamp HP4-L-DC110V 110 88 16.5 121 7,000 15.7 1.7
1. The range of coil current for AC relays
is ±15% (60 Hz). For DC relays it is
±10% at 20°C, 68°F.
2. The HP relay will operate in a range
from 80% to 110% of the nominal coil
voltage. It is, however, recommended
that the relay be used in the range of
85% to 110% of the nominal coil
voltage, with the temporary voltage
variation taken into consideration.
3. When the operating voltage of AC
relays drops below 80% of the nominal
coil voltage, the relay will generate a
considerable amount of heat which is
not recommended for maximum
efciency.
4. The coil resistance of DC types is the
measured value of the coil at a
temperature of 20°C 68°F. If the coil
temperature changes by ±1°C, the
measured value of the coil resistance
should be increased or decreased by
0.4%.
5. For applications from 220 V to 240 V
DC, connect a resistor in series with
the relay coil. See chart for resistor
values.
Voltage 2 Form C 3 Form C 4 Form C
220 V DC
7.3 k
(5 W)
7.45 k
(5 W)
7 k
(5 W)
240 V DC
8.7 k
(5 W)
8.8 k
(5 W)
8.3 k
(5 W)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

HP2-L-DC24V

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays 2 Form C, 24VDC 10A 2 Form C
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: