Cat. No. P063I-E-01 09/10 Specifications subject to change without notice. © 2010 Omron Electronics LLC
Modbus/TCP Master for CP1L and CP1H Micro PLCs
Modbus/TCP Slave for CJ2M-CPU3x, CP1L and CP1H PLCs
The CP1W-MODTCP01-US allows Omron CP1L, CP1H and CJ2M-CPU3x PLCs to function as slave nodes on a
Modbus/TCP network. The adapter can function as either a Modbus/TCP Master or as a Modbus/TCP Slave, but not
both simultaneously. The Modbus/TCP Master mode is used to control/monitor IO blocks and other remote devices.
The Modbus/TCP Slave mode responds to commands from a Modbus/TCP Master such as a PC or PLC.
Key Features and Benefits
• Most Popular Network – Modbus/TCP/IP is the most popular remote I/O Ethernet network for PLC systems in the world
• Simple setup – Web page configuration for IP Address & Master/Slave selection
• Operates as a Modbus/TCP Master or Slave - As a Master, the adapter is used to control/monitor IO blocks and other remote
devices. As a Modbus/TCP Slave it responds to commands from a Modbus/TCP Master (PC, PLC, other)
• Perfect for Data Collection – The CP1W- MODTCP01-US turns a CJ2M-CPU3x, CP1L/H PLC into a Modbus/TCP Slave that can
easily share information with a Modbus/TCP Master for remote data collection or control
• High Speed Counters & Expandable I/O – 4 x 100Khz counters built-in, up to 320 I/O (CP1H-X) & 180 I/O (CP1L-M60) PLCs
• Programmable Slave for Motion, Temperature Control – Each PLC can be a powerful motion controller* (CP1H - 4 Axis, CP1L
– 2 Axis) with high speed interrupts, Real Time Clock, PID, Floating Point Math and is expandable with digital I/O or analog for
Temperature or Process Control. The addition of a Modbus/TCP adapter turns the PLC into a Low Cost Programmable Slave
*Transistor models
• Supports Multiple Connections - If the adapter is configured in Modbus/TCP slave mode, it can also support communications to
CX-Programmer, NS HMI or other devices that use FINS (Omron’s open communication protocol)
• Gateway for Modbus/TCP & FINS Ethernet – Allows CS/CJ PLCs with Ethernet or EtherNet/IP to communicate using FINS
through a CP1 PLC as a Modbus/TCP Slave
Typical Master/Slave Configuration
Specification
Item Description
Part #: CP1W-MODTCP01-US CJ2M-CPU3x, CP1L/H - Modbus/TCP Slave or CP1L/H Modbus/TCP Master (not both simultaneously)
Type, Max # of Modbus Slave nodes 100Base-TX (Can be used as 10Base-T), 254 Max Slave Nodes
Applicable PLCs CP1L-L14, CP1L-L20, CP1L-M30, CP1L-M40, CP1L-M60, CP1H
Max Distance, Communication Method 100 m (distance between hub and node), Modbus/TCP/IP protocol
Max number of units mounted in PLC 2 (1 Modbus/TCP Master, 1 Modbus/TCP Slave)(CP1L 30 I/O or more or CP1H)
Max connection/adapter - Slave mode 4 – (2 Modbus/TCP connections & 2 FINS)
Max connection/adapter - Master mode 1 connection (CP1L, CP1H PLCs only can be set to Master Mode)
Current IP Address (Slave mode) D1200, D1201 (D1200=1st & 2nd Octets in Hex, D1201=3rd & 4th Octets in Hex)
Default IP Address, Web Page Set-up 192.168.250.11 Web Page Set-up: http://192.168.250.11
CP1W-MODTCP01-US
CP1 Modbus/TCP Adapter
CJ2M-CPU3x
CP1H CP1H CP1H CP1L CP1L
Modbus
TCP Slaves can
erform Motion Control
Process Control
etc.
Modbus/TCP Master
W4S Ethernet Switch
W4S Ethernet
Switch