ELECTRICAL CHARACTERISTICS—Single Supply
(V+ = +12V, V- = 0, V
IH
= 2.4V, V
IL
= 0.8V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 2)
Note 2: The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 3: Flatness is defined as the difference between the maximum and minimum value of on-resistance as measured over the
specified analog signal range.
Note 4: Leakage parameters are 100% tested at maximum rated hot temperature and guaranteed by correlation at T
A
= +25°C.
Note 5: Off-isolation = 20log
10
[V
COM
/ (V
NC
or V
NO
)], V
COM
= output, V
NC
or V
NO
= input to off switch.
Note 6: Guaranteed by testing with dual supplies.
Note 7: -40°C specifications are guaranteed by design.