ALFG1PF09

LF-G (ALFG)
–4–
ASCTB196E 201606-T
2. High capacity type (Contact Gap 1.5 mm .059 inch type)
3. High capacity type (Contact Gap 1.8 mm .071 inch type)
1. Coil temperature rise
Sample: ALFG2PF09, 6 pcs.
Point measured: coil inside
Ambient temperature: 20°C 68°F, 60°C 140°F
Contact carrying current: 31A
2. Ambient temperature characteristics and coil
applied voltage
Coil applied voltage, %V
20°C
60°C 140°F 31A
60°C 140°F 0A
68°F 31A
20°C 68°F 0A
1401201008060
100
80
60
40
20
Temperature rise, °C
Coil applied voltage, %V
900 1020304050607080
19432 50 68 86 104 122 140 158 176
180
140
100
60
0
Contact carrying
current: 31A
Pick-up voltage
Coil & contact
no carrying current
*Inside the coil temperature
155°C 311°F (UL Class F)
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 155°C 311°F)
°F
Ambient temperature, °C
3. Electrical life test
(31A 250V AC cos
φ
= 0.8 Inductive load)
Sample: ALFG2PF09, 6 pcs.
Operation frequency: ON:OFF = 0.1s:10s
Ambient temperature: 85°C 185°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
Contact welding detection
and Mis-contacting
detection circuit
250V AC
9V DC
Pick-up and drop-out voltage, V
30
10
9
8
7
6
5
4
3
2
1
0
Max.
Min.
x
Max.
Min.
x
No. of operations, ×10
4
Pick-up voltage
Drop-out voltage
Contact resistance, mΩ
No. of operations, ×10
4
30
100
90
80
70
60
50
40
30
20
10
0
Max.
Min.
x
1. Coil temperature rise
Sample: ALFG2PF091, 6 pcs.
Point measured: coil inside
Ambient temperature: 20°C 68°F, 60°C 140°F
Contact carrying current: 33A
2. Ambient temperature characteristics and coil
applied voltage
1401201008060
120
100
80
60
40
20
248
212
176
140
104
68
Coil applied voltage, %V
20°C
60°C 140°F 33A
60°C 140°F 0A
68°F 33A
20°C 68°F 0A
Temperature rise, °C °F
0
32
10
50
20
68
30
86
40
104
50
122
60
140
70
158
80
176
90
194
180
140
100
60
Coil applied voltage, %V
Ambient temperature, °C °F
Contact carrying
current: 33A
Pick-up voltage
Coil & contact
no carrying current
*Inside the coil temperature
155°C 311°F (UL Class F)
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 155°C 311°F)
3. Electrical life test
(33A 250V AC cos
φ
= 0.8 Inductive load)
Sample: ALFG2PF091, 6 pcs.
Operation frequency: ON:OFF = 0.1s:10s
Ambient temperature: 85°C 185°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
Contact welding detection
and Mis-contacting
detection circuit
250V AC
9V DC
Pick-up and drop-out voltage, V
No. of operations, ×10
4
30
10
9
8
7
6
5
4
3
2
1
0
Max.
Min.
x
Max.
Min.
x
Pick-up voltage
Drop-out voltage
No. of operations, ×10
4
Max.
Min.
x
Contact resistance, mΩ
30
100
90
80
70
60
50
40
30
20
10
0
LF-G (ALFG)
–5–
ASCTB196E 201606-T
DIMENSIONS (mm inch)
SAFETY STANDARDS
EN/IEC VDE Certified
INSULATION CHARACTERISTIC (IEC61810-1)
Item
UL/C-UL (Recognized) VDE (VDE0435) (Certified)
File No. Contact rating Temp. Cycles File No. Contact rating Temp. Cycles
Standard type
(Contact GAP 1.5 mm/1.8 mm
.059 inch/.071 inch)
E43028 22A 277V AC General Use 85°C 185°F 3 × 10
4
40023067 22A 250V AC (cos
φ
=0.8) 85°C 185°F 3 × 10
4
22A 277V AC Resistive 85°C 185°F 3 × 10
4
——
22A 30V DC Resistive 40°C 104°F 3 × 10
4
——
High capacity
type
1.5 mm .059 inch E43028 31A 277V AC General Use 85°C 185°F 3 × 10
4
40023067 31A 250V AC (cos
φ
=0.8) 85°C 185°F 3 × 10
4
1.8 mm .071 inch E43028 33A 277V AC General Use
33A 30V DC Resistive
85°C 185°F
40°C 104°F
3 × 10
4
3 × 10
4
40023067 33A 250V AC (cos
φ
=0.8) 85°C 185°F 3 × 10
4
Item Characteristic
Clearance/Creepage distance (IEC61810-1) Min. 5.5mm/5.5mm
Category of protection (IEC61810-1) RT II
Tracking resistance (IEC60112) PTI 175
Insulation material group III a
Over voltage category III
Rated voltage 250V
Pollution degree 2
Type of insulation (Between contact and coil) Reinforced insulation
Type of insulation (Between open contacts) Full disconnection
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
23.3
.917
4.0
.157
0.5
.020
15.7
.618
12.0
.472
22.0
.866
27.6
1.087
30.1
1.185
0.3
.012
0.8
.031
1.6
.063
1.6
.063
0.8
.031
1.6
.063
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
10.0±0.1
.394±.004
27.6±0.1
1.087±.004
12.0±0.1
.472±.004
13.8±0.1
.543±.004
12.0±0.1
.472±.004
1.8 dia.
.071 dia.
1.8 dia.
.071 dia.
2.0 dia.
.079 dia.
2.0 dia.
.079 dia.
NO COM
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
LF-G (ALFG)
–6–
ASCTB196E 201606-T
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. Usage, transport and storage
conditions
1) Temperature:
–40 to +60°C –40 to +140°F (When
nominal coil voltage applied)
–40 to +85°C –40 to +185°F (When coil
holding voltage is 45% to 80% of the
nominal coil voltage)
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
–40 to +85°C –40 to +185°F (When 45% to
80%V of coil holding voltage)
85
5
060–40
Humidity, %RH
Tolerance range
+32 +140–40
Temperature, °C °F
(Avoid freezing
when used at
temperatures lower
than 0°C
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
32°F)
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
850–40
+185+32–40
Temperature, °C °F

ALFG1PF09

Mfr. #:
Manufacturer:
Panasonic
Description:
General Purpose Relays 1 FORM A 9VDC STANDARD TYPE SMD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union