NCV5701A, NCV5701B, NCV5701C
www.onsemi.com
7
Table 2. ABSOLUTE MAXIMUM RATINGS (Note 1)
Parameter
Symbol Minimum Maximum Unit
Differential Power Supply V
CC
−V
EE
(V
max
) 0 36 V
Positive Power Supply V
CC
−GND −0.3 22 V
Negative Power Supply V
EE
−GND −18 0.3 V
Gate Output High (V
O
, V
OH
)−GND V
CC
+ 0.3 V
Gate Output Low (V
O
, V
OL
)−GND V
EE
− 0.3 V
Input Voltage V
IN
−GND −0.3 5.5 V
DESAT Voltage V
DESAT
−GND −0.3 V
CC
+ 0.3 V
FLT current
Sink
Source
I
FLT−SINK
I
FLT−SRC
20
25
mA
Power Dissipation
SO−8 package
PD 700 mW
Maximum Junction Temperature T
J(max)
150 °C
Storage Temperature Range TSTG −65 to 150 °C
ESD Capability, Human Body Model (Note 2) ESDHBM 4 kV
ESD Capability, Machine Model (Note 2) ESDMM 200 V
Moisture Sensitivity Level MSL 1 −
Lead Temperature Soldering
Reflow (SMD Styles Only), Pb−Free Versions (Note 3)
T
SLD
260 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
2. This device series incorporates ESD protection and is tested by the following methods:
ESD Human Body Model tested per AEC−Q100−002 (EIA/JESD22−A114)
ESD Machine Model tested per AEC−Q100−003 (EIA/JESD22−A115)
Latchup Current Maximum Rating: ≤100 mA per JEDEC standard: JESD78, 125°C
3. For information, please refer to our Soldering and Mounting Techniques Reference Manual, SOLDERRM/D.
Table 3. THERMAL CHARACTERISTICS
Parameter Symbol Value Unit
Thermal Characteristics, SOIC−8 (Note 4)
Thermal Resistance, Junction−to−Air (Note 5)
R
q
JA
176
°C/W
4. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
5. Values based on copper area of 100 mm
2
(or 0.16 in
2
) of 1 oz copper thickness and FR4 PCB substrate.
Table 4. OPERATING RANGES (Note 6)
Parameter
Symbol Min Max Unit
Differential Power Supply V
CC
−V
EE
(V
max
) 30 V
Positive Power Supply V
CC
UVLO 20 V
Negative Power Supply V
EE
−15 0 V
Input Voltage V
IN
0 5 V
Input pulse width t
on
40 ns
Ambient Temperature T
A
−40 125 °C
6. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond