2
HR41 Series●Waterproof Connectors for Outdoor Use
■
Product Specifi cations
Ratings
Current Rating (Note 3) 24A (Ambient Temperature 25°C) Operating Temperature Range - 40 to +105°C (Note 1)
Voltage Rating AC 1000V, DC 1000V Storage Temperature Range - 10 to +60°C
UL, TÜV
Current Rating (Note 3)
20A (5 position, incudes 4 position
excluding ground are use)
Operating Temperature Range - 40 to +65°C (Note 1)
Voltage Rating AC 600V, DC 600V Storage Temperature Range - 10 to +60°C
Note 1 : Including temperature rise due to current carrying.
Items Specifi cations Conditions
1. Contact resistance Maximum of 2mø Measured at DC 1A
2. Insulation resistance Minimum of 5,000Mø Measured at DC 500V
3. Withstand voltage No fl ashover or breakdown
3 pos. : Apply AC 4,260V for 1 minute
5 pos. : Apply AC 2,200V for 1 minute
4. Vibration resistance No electrical discontinuity of 10µs or more
10 cycles in 3 axial directions at a frequency of 10 -
500 - 10Hz, half amplitude 0.75mm and 11 min/cycle
5. Shock resistance No electrical discontinuity of 10µs or more
Acceleration 490m/s
2
, duration 11ms, half-sine wave,
3 times each for 3 axial directions
6. Durability Contact resistance: Maximum of 4mø 200 mating cycles
7. Temperature cycles
Insulation resistance:
Maximum of 5,000Mø
5 cycles of (-55ç for 30min
→
ambient temp for 2 to 3 minutes
→
85ç for 30min
→
ambient temp for 2 to 3 minutes)
8. Salt water spray Functionality should not be damaged.
Spray 5% concentration salt water for 1,000 hours in mated connector condition.
9. Moisture resistance
Insulation resistance Minimum of 50Mø (high humidity)
Minimum of 500Mø (dry)
At temperature 40°C, humidity 90 to 95%, for 96 hours
10. Water resistance No water intrusion into connector inside
Left submerged in water in mated condition at depth of
2m for 14 days.
Depending on the structure and use of the cable, cable clamping force and cable stress, the waterproof performance may differ
from what is noted above. Please check the performance before using the connector.
■
Materials / Finish
Component Materials Finish UL standard (noncombustible)
Insulator Polyamide resin, PBT resin
----------------------
UL94V-0
Contact Copper alloy Partially gold plated
----------------------
O-ring, gasket Silicon rubber
---------------------- ----------------------
50.00
45.00
40.00
35.00
30.00
25.00
20.00
15.00
10.00
5.00
0.00
0102030
Ambient Temperature[°C]
HR41 (3 contacts conducting)
Derating Curve
Current[A]
40
50
60 70
Basic Curve
Derating Curve
Note 2 : The derating curve is derived from the basic curve multiplied by the derating factor of 0.8.
Note 3 : The value of rated current varies with the ambient temperature. It is recommended to use the product within the
derating curve zone.
When using a UL or T
Ü
V approved product, please use the product within the specifi ed range as well as the derating
curve aera.
Note 4 : The measurement method of the derating curve is shown below.
• Test specimen : This product, unused prior to testing.
• Test cable conductor cross sectional area : 5.5mm
2
• Test condition : Power supplied while the specimen is in a stationary state and then measured.
Apr.1.2017 Copyright 2017 HIROSE ELECTRIC CO., LTD. All Rights Reserved.