14
MY MY
Type Contact form Coil ratings Contact ratings
MY■
DPDT 6 to 240 VAC 5 A, 120 VAC (Resistive)
6 to 120 VDC 5 A, 28 VDC (Resistive)
5 A, 240 VAC (Inductive)
3PDT 5 A, 28 VDC (Resistive)
5 A, 240 VAC (Resistive)
4PDT 3 A, 28 VDC (Resistive)
3 A, 120 VAC (Inductive)
1.5 A, 240 VAC (Inductive)
5 A, 240 VAC (Inductive, same polarity)
5 A, 28 VDC (Resistive, same polarity)
MY2K-■
DPDT 5 to 120 VAC 3 A, 240 VAC (Resistive)
5 to 48 VDC 3 A, 28 VDC (Resistive)
■ APPROVALS
UL recognized type (File No. E41515)
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the
performance characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
Type Contact form Coil ratings Contact ratings
MY■
DPDT 6 to 240 VAC 5 A, 28 VDC (Resistive)
3PDT 6 to 120 VDC 5 A, 240 VAC (Inductive)
4PDT 3 A, 28 VDC (Resistive)
3 A, 240 VAC (Inductive)
5 A, 240 VAC (Inductive, same polarity)
5 A, 28 VDC (Resistive, same polarity)
MY2K-■
DPDT 5 to 120 VAC 3 A, 240 VAC (General purpose)
5 to 48 VDC 3 A, 30 VDC (Resistive)
CSA certified type (File No. LR31928)
Type Contact form Coil ratings Contact ratings
MY■
DPDT 6 to 240 VAC 2 A, 30 VDC (Inductive)
4PDT 6 to 120 VDC 2 A, 200 VAC (Inductive)
1.5 A, 30 VDC (Inductive)
0.8 A, 200 VAC (Inductive)
1.5 A, 115 VAC (Inductive)
LR (Lloyd's Register) approved type (File No. 563KOB-204524)
Type Contact form Coil ratings Contact ratings
MY■
-SV DPDT 6 to 240 VAC 5 A, 220 VAC (Resistive)
3PDT 6 to 110 VDC 5 A, 24 VDC (Resistive)
4PDT
SEV listed type (File No. D791/63 [2- & 4-pole], D791/91 [3-pole])
■ HINTS ON CORRECT USE
When using the relay rated at 120 VAC at a supply voltage of
240 VAC, be sure to connect external resistors Rs and Rr to
the relay.