13
MY MY
Note: 1. Pay special attention to the polarities when using the DC type.
2. The release time is somewhat longer, but satisfies the standard specifications of 25 ms.
3. The reverse-breakdown voltage of the diode is 1,000 VDC.
4. Available on DC versions only.
Diode Surge Suppression
Specifications and dimensions same as the standard
type with the following exceptions.
Terminal arrangement/internal connections: MY2(N)-
D(2) is the same as the MY4(N)-D(2) with the exception
of the contact configuration.
Ambient operating temperature: -55° to 60°C (-67° to
140°F).
Characteristic Data
Without RC circuit With RC circuit
Push-to-test button
MY
12 Mounting holes
When mounting the relay, use the connecting socket PYC-P2 shown
in “ACCESSORIES” section. The mounting hole dimensions shown
here are applicable to the relay with mounting stud.
Note: The dimension drawings show the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-pole type.
Terminal arrangement/Internal connections (Bottom view)
MY4-D MY4N-D2 MY4N-D2
6, 12, 24, 48 6, 12, 24, 48 VDC 100/110 VDC
100/110 VDC
Connecting sockets
Use the standard MY4 (4PDT) sockets with the terminal arrangements listed below.
Terminal arrangement/Internal connections (Bottom view)
AC DC
Note: 1. R is a resistor for ampere-turn compensation, and is incorporated in the relays rated at 50 VAC or above.
2. Pay attention to the polarity of the set and reset coils, as incorrect connection of positive and negative terminals will result in
malfunctioning of the relay.
14
MY MY
Type Contact form Coil ratings Contact ratings
MY
DPDT 6 to 240 VAC 5 A, 120 VAC (Resistive)
6 to 120 VDC 5 A, 28 VDC (Resistive)
5 A, 240 VAC (Inductive)
3PDT 5 A, 28 VDC (Resistive)
5 A, 240 VAC (Resistive)
4PDT 3 A, 28 VDC (Resistive)
3 A, 120 VAC (Inductive)
1.5 A, 240 VAC (Inductive)
5 A, 240 VAC (Inductive, same polarity)
5 A, 28 VDC (Resistive, same polarity)
MY2K-
DPDT 5 to 120 VAC 3 A, 240 VAC (Resistive)
5 to 48 VDC 3 A, 28 VDC (Resistive)
APPROVALS
UL recognized type (File No. E41515)
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the
performance characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
Type Contact form Coil ratings Contact ratings
MY
DPDT 6 to 240 VAC 5 A, 28 VDC (Resistive)
3PDT 6 to 120 VDC 5 A, 240 VAC (Inductive)
4PDT 3 A, 28 VDC (Resistive)
3 A, 240 VAC (Inductive)
5 A, 240 VAC (Inductive, same polarity)
5 A, 28 VDC (Resistive, same polarity)
MY2K-
DPDT 5 to 120 VAC 3 A, 240 VAC (General purpose)
5 to 48 VDC 3 A, 30 VDC (Resistive)
CSA certified type (File No. LR31928)
Type Contact form Coil ratings Contact ratings
MY
DPDT 6 to 240 VAC 2 A, 30 VDC (Inductive)
4PDT 6 to 120 VDC 2 A, 200 VAC (Inductive)
1.5 A, 30 VDC (Inductive)
0.8 A, 200 VAC (Inductive)
1.5 A, 115 VAC (Inductive)
LR (Lloyd's Register) approved type (File No. 563KOB-204524)
Type Contact form Coil ratings Contact ratings
MY
-SV DPDT 6 to 240 VAC 5 A, 220 VAC (Resistive)
3PDT 6 to 110 VDC 5 A, 24 VDC (Resistive)
4PDT
SEV listed type (File No. D791/63 [2- & 4-pole], D791/91 [3-pole])
HINTS ON CORRECT USE
When using the relay rated at 120 VAC at a supply voltage of
240 VAC, be sure to connect external resistors Rs and Rr to
the relay.
15
MY MY
OMRON ELECTRONICS, INC. OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. GC RLY6 9/97 Specifications subject to change without notice. Printed in the U.S.A.

MY2-D DC12 (S)

Mfr. #:
Manufacturer:
Description:
General Purpose Relays Relay
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union