6
Switching Specications
Over recommended temperature (T
A
= 0°C to 70°C) V
CC
= 5 V, I
F
= 16 mA unless otherwise specied.
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Propagation Delay Time
to Logic Low at Output
t
PHL
0.2 0.8
Ps
T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
5,6,9 9
1.0
Propagation Delay Time
to Logic High at Output
t
PLH
0.6 0.8 T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
5,6,9 9
1.0
Common Mode Transient
Immunity at Logic High
Level Output
|CM
H
|15 30
kV/Ps
V
CM
=1500 V
p-p
I
F
= 0 mA, T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
10 8,9
Common Mode Transient
Immunity at Logic Low
Level Output
|CM
L
|15 30 V
CM
=1500 V
p-p
I
F
= 16 mA, T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
10 8,9
* All typicals at T
A
= 25°C.
Package Characteristics
Over recommended temperature (T
A
= 0°C to 70°C) unless otherwise specied. All typicals at T
A
= 25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Input-Output Momentary
Withstand Voltage*
V
ISO
5000 Vrms
RH d 50%, t = 1 min;
T
A
= 25°C
6,7
Input-Output Resistance R
I-O
10
12
:
V
I-O
= 500 Vdc 6
Input-Output Capacitance C
I-O
0.6 pF f = 1 MHz; V
I-O
= 0 Vdc 6
* The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable).
Notes:
1. Derate linearly above 85°C free-air temperature at a rate of 0.5 mA/°C.
2. Derate linearly above 85°C free-air temperature at a rate of 1.0 mA/°C.
3. Derate linearly above 85°C free-air temperature at a rate of 1.1 mW/°C.
4. Derate linearly above 85°C free-air temperature at a rate of 2.3 mW/°C.
5. CURRENT TRANSFER RATIO in percent is dened as the ratio of output collector current, I
O
, to the forward LED input current, I
F
, times 100.
6. Device considered a two terminal device: pins 2 and 3 shorted together, and pins 5, 6, 7 and 8 shorted together.
7. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage t 6000 V
RMS
for 1 second (leakage detection
current limit, I
I-O
d 5 PA).
8. Common transient immunity in a Logic High level is the maximum tolerable (positive) dV
CM
/dt on the rising edge of the common mode pulse, V
CM
,
to assure that the output will remain in a Logic High state (i.e., V
O
> 2.0 V). Common mode transient immunity in a Logic Low level is the maximum
tolerable (negative) dV
CM
/dt on the falling edge of the common mode pulse signal, V
CM
to assure that the output will remain in a Logic Low state
(i.e., V
O
< 0.8 V).
9. The 1.9 k: load represents 1 TTL unit load of 1.6 mA and the 5.6 k:pull-up resistor.
10. Use of a 0.1 mF bypass capacitor connected between pins 4 and 6 is recommended.