ACPL-K453-020E

4
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060 only)
Description Symbol Characteristic Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage d 300 V rms
for rated mains voltage d 450 V rms
for rated mains voltage d 600 Vrms
for rated mains voltage d 1000 Vrms
I-IV
I-III
I-III
I-II
Climatic Classication 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec
Partial Discharge < 5 pC,
V
PR
2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and sample test, t
m
= 60 sec,
Partial Discharge < 5 pC
V
PR
1710 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
V
IOTM
8000 V
peak
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
T
S
I
S,INPUT
P
S,OUTPUT
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
10
9
:
* Refer to the optocoupler section of the Designer’s Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test proles.
5
Absolute Maximum Ratings
Parameter Abs. Max.
Storage Temperature -55°C to +125°C
Operating Temperature -55°C to +100°C
Average Input Current - I
F
25 mA
[1]
Peak Input Current - I
F
50 mA
[2]
(50% duty cycle, 1 ms pulse width)
Peak Transient Input Current - I
F
1.0 A (d1 ms pulse width, 300 pps)
Reverse Input Voltage - V
R
(Pin 3-2) 5 V
Input Power Dissipation 45 mW
[3]
Average Output Current - I
O
(Pin 6) 8 mA
Peak Output Current 16 mA
Output Voltage - V
O
(Pin 6-5) -0.5 V to 20 V
Supply Voltage - V
CC
(Pin 8-5) -0.5 V to 30 V
Output Power Dissipation 100 mW
[4]
Solder Reow Temperature Prole see Package Outline Drawings section
Electrical Specications
Over recommended temperature (T
A
= 0°C to 70°C) unless otherwise specied.
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Current
Transfer Ratio
CTR 19 24 50 % T
A
= 25°C V
O
= 0.4 V V
CC
= 4.5
VI
F
= 16
mA
1, 2, 4 5
15 25 V
O
= 0.5 V
Logic Low
Output Voltage
V
OL
0.1 0.4 V T
A
= 25°C I
O
= 3.0 mA
0.5 I
O
= 2.4 mA
Logic High
Output Current
I
OH
0.003 0.5
PA
T
A
= 25°C V
O
= V
CC
= 5.5 V I
F
= 0 mA 7
0.01 1 T
A
= 25°C V
O
= V
CC
= 15.0 V
50
Logic Low
Supply Current
I
CCL
50 200 I
F
= 16 mA, V
O
= Open, V
CC
= 15 V 10
Logic High
Supply Current
I
CCH
0.02 1 T
A
= 25°C I
F
= 16 mA, V
O
= Open,
V
CC
= 15 V
10
2
Input Forward
Voltage
V
F
1.5 1.7 V T
A
= 25°C I
F
= 16 mA 3
Input Reverse
Breakdown Voltage
BV
R
5
I
R
= 10 PA
Temperature
Coecient of
Forward Voltage
'V
F
/
'T
A
-1.6 mV/°C I
F
= 16 mA
Input
Capacitance
C
IN
60 pF f = 1 MHz, V
F
= 0
*All typicals at T
A
= 25°C.
6
Switching Specications
Over recommended temperature (T
A
= 0°C to 70°C) V
CC
= 5 V, I
F
= 16 mA unless otherwise specied.
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Propagation Delay Time
to Logic Low at Output
t
PHL
0.2 0.8
Ps
T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
5,6,9 9
1.0
Propagation Delay Time
to Logic High at Output
t
PLH
0.6 0.8 T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
5,6,9 9
1.0
Common Mode Transient
Immunity at Logic High
Level Output
|CM
H
|15 30
kV/Ps
V
CM
=1500 V
p-p
I
F
= 0 mA, T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
10 8,9
Common Mode Transient
Immunity at Logic Low
Level Output
|CM
L
|15 30 V
CM
=1500 V
p-p
I
F
= 16 mA, T
A
= 25°C
R
L
= 1.9 k:
C
L
= 15 pF
10 8,9
* All typicals at T
A
= 25°C.
Package Characteristics
Over recommended temperature (T
A
= 0°C to 70°C) unless otherwise specied. All typicals at T
A
= 25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Input-Output Momentary
Withstand Voltage*
V
ISO
5000 Vrms
RH d 50%, t = 1 min;
T
A
= 25°C
6,7
Input-Output Resistance R
I-O
10
12
:
V
I-O
= 500 Vdc 6
Input-Output Capacitance C
I-O
0.6 pF f = 1 MHz; V
I-O
= 0 Vdc 6
* The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable).
Notes:
1. Derate linearly above 85°C free-air temperature at a rate of 0.5 mA/°C.
2. Derate linearly above 85°C free-air temperature at a rate of 1.0 mA/°C.
3. Derate linearly above 85°C free-air temperature at a rate of 1.1 mW/°C.
4. Derate linearly above 85°C free-air temperature at a rate of 2.3 mW/°C.
5. CURRENT TRANSFER RATIO in percent is dened as the ratio of output collector current, I
O
, to the forward LED input current, I
F
, times 100.
6. Device considered a two terminal device: pins 2 and 3 shorted together, and pins 5, 6, 7 and 8 shorted together.
7. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage t 6000 V
RMS
for 1 second (leakage detection
current limit, I
I-O
d 5 PA).
8. Common transient immunity in a Logic High level is the maximum tolerable (positive) dV
CM
/dt on the rising edge of the common mode pulse, V
CM
,
to assure that the output will remain in a Logic High state (i.e., V
O
> 2.0 V). Common mode transient immunity in a Logic Low level is the maximum
tolerable (negative) dV
CM
/dt on the falling edge of the common mode pulse signal, V
CM
to assure that the output will remain in a Logic Low state
(i.e., V
O
< 0.8 V).
9. The 1.9 k: load represents 1 TTL unit load of 1.6 mA and the 5.6 k:pull-up resistor.
10. Use of a 0.1 mF bypass capacitor connected between pins 4 and 6 is recommended.

ACPL-K453-020E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 1MBd 15000V/us
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: