Over Voltage Protection
Over Temperature Protection
LED Indicator
The converter shuts off to protect itself when the output voltage drawn exceeds 115~135% of its output rating. It must be repowered on to recover.
The converter shuts off to protect itself when the built-in temperature sensor mounted on the main power transformer senses a high temperature. The output recovers
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.
automatically if the temperature drops below the limit.
2.Increase the output voltage (current does not change). Because RSD-200 series have no reverse blocking diode in the unit, you should add an external blocking diode
to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
-
I/P
+
I/P
PS2
2
V
I/P
-
E
IN
PS1
I/P
1
+
V
-V
D
2
V1+V2
L
R
1
D
+V
Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition
is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it's not suitable to operate within
the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
0 50 100 150
50
100
Vo(%)
Io(%)
Derating Curve
AMBIENT TEMPERATURE ( )℃
LOAD (%)
100
100
20
40
60
80
-40 20 30 40 50 55 60 70
(HORIZONTAL)
Overload
region
200W Railway Single Output DC-DC Converter
RSD-200 series
File Name:RSD-200-SPEC 2018-01-15
a.Single unit operation
de-rating output current when ambient temperature is between 55-70 , please refer to the de-rating curve as below.℃
If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires℃