HLP-40H-36

THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
287.9Khrs min. MIL-HDBK-217F (25 )
147*53*27mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
0.2Kg;72pcs/15.4Kg/1.09CUFT
Protection type : Shut down o/p voltage, re-power on to recover
40W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp locations
100% full load burn-in test
3 years warranty
Features :
HLP-40H series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
87%
87%
88%
88%
88.5%
89%
89.5%89% 89.5%
±2.5%
2 ~ 3.33A
±2.0%
1.6 ~ 2.67A
±1.0%
1.2 ~ 2A
±1.0%
1 ~ 1.67A
±1.0%
0.8 ~ 1.34A
±1.0%
0.67 ~ 1.12A
±1.0%
0.5 ~ 0.84A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
0.45 ~ 0.75A
±0.5%
±0.5%
±1.0%
0.58 ~ 0.96A
±0.5%
±0.5%
12V
HLP-40H-12 HLP-40H-15 HLP-40H-20 HLP-40H-24 HLP-40H-30 HLP-40H-36 HLP-40H-42 HLP-40H-48 HLP-40H-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
3.33A 2.67A 2A 1.67A
1.34A
1.12A
0.84A
40W 40W 40W 40.1W 40.2W
40.3W
40.3W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
300mVp-p
44 ~ 53V10.8 ~ 13.5V
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
42V
25.2 ~ 42V
0.96A
40.3W
300mVp-p
40 ~ 46V
18 ~ 24V15 ~ 21V 23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
48 ~ 58V 59 ~ 68V
54 ~ 65V
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A, EAC TP TC 020
EMC IMMUNITY
EMC EMISSION
SELV
MM
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13, ,GB19510.14 GB19510.1,
EAC TP TC 004 TUV EN60950-1, EN60335-1approved ; design refer to UL60950-1,
500ms, 80ms at full load 230VAC / 115VAC
File Name:HLP-40H-SPEC 2018-01-09
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
S
&
E
( except for 48V,54V )( for 48V,54V only)
Mechanical Specification
Unit:mm
AC Input Connector (CN1) : JST B6P-VH or equivalent
Pin No.
1
3
6
2,4,5
Assignment
AC/L
AC/N
FG
No Pin
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No.
1
2
3,4
5,6
Assignment
DIM+
DIM-
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
3max.
27max.
53
43
T3.15A/300V
FS1
CN2
5
3
4
2
1
6
CN1
5
3
4
2
1
6
3.5
140
147
5
-V
+V
Io
ADJ
SVR1 SVR2
Vo
ADJ
fosc : 100KHz
Block Diagram
Derating Curve Static Characteristics
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 305
100
90
80
70
60
50
40
LOAD (%)
230VAC
Input only
AMBIENT TEMPERATURE ( )
LOAD (%)
-40 -25 0-10 15 30 50 60 70
20
40
50
60
80
100
(HORIZONTAL)
DIM+
DIM-
DETECTION
PWM & PFC
CIRCUIT
O.L.P.O.T.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
40W Single Output Switching Power Supply
HLP-40H series
File Name:HLP-40H-SPEC 2018-01-09
: Grounding required
70
72
74
76
78
80
82
84
86
88
90
92
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
277VAC
230VAC
115VAC
0.85
0.86
0.87
0.88
0.89
0.9
0.91
0.92
0.93
0.94
0.95
0.96
0.97
0.98
0.99
1
50% 60% 70% 80% 90% 100%
277VAC
230VAC
115VAC
DRIVING METHODS OF LED MODULE
HLP-40H series possess superior working efficiency that up to 89.5% can be reached in field applications.
EFFICIENCY vs LOAD (48V Model)
Power Factor Characteristic
LOAD
EFFICIENCY (%)
LOAD
Constant Current Mode
(40W)
40W Single Output Switching Power Supply
HLP-40H series
File Name:HLP-40H-SPEC 2018-01-09
PF
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
Typical LED power supply I-V curve
Vo(%)
100
60
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.

HLP-40H-36

Mfr. #:
Manufacturer:
MEAN WELL
Description:
LED Power Supplies 40.3W 36V 1.12A 90-305VAC Dimming
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union