MAX14523CATA+T

MAX14523A/MAX14523AL/MAX14523B/MAX14523C
250mA to 1.5A, Adjustable
Current-Limit Switches
_______________________________________________________________________________________ 7
Typical Operating Characteristics (continued)
(V
IN
= +3.3V, C
IN
= 1µF, C
OUT
= 1µF, R
SETI
= 94.2kΩ, T
A
= +25°C, unless otherwise noted.)
CURRENT LIMIT RESPONSE
MAX14523A toc13
2
μ
s/div
V
OUT
2V/div
I
OUT
10A/div
SUDDEN SHORT
APPLIED AT OUTPUT
CURRENT LIMIT RESPONSE
MAX14523A toc14
20ms/div
V
OUT
2V/div
I
OUT
1A/div
R
LOAD
= 16.5Ω TO SUDDEN SHORT
APPLIED AT OUTPUT
FLAG RESPONSE (OVERLOAD CONDITION)
MAX14523A toc15
20ms/div
V
FLAG
2V/div
I
OUT
1A/div
R
LOAD
= 16.5Ω TO SUDDEN SHORT
APPLIED AT OUTPUT
Pin Description
PIN
MAX14523AL
MAX14523A
MAX14523B
MAX14523C
NAME FUNCTION
1, 6 1, 6 N.C. No Connection. Not internally connected. Connect N.C. to GND or leave unconnected.
2 2 FLAG
Open-Drain, Overload Indicator Output. FLAG goes low when the overload fault
duration exceeds the blanking time, reverse current is detected, thermal shutdown
mode is active, or SETI is connected to ground.
3 3 SETI
Overload-Current Limit Adjust. Connect a resistor from SETI to GND to program the
overcurrent limit. If SETI is connected to GND the switch turns off and FLAG is
asserted. If SETI is unconnected the current limit is at 0mA. Do not connect any
capacitance larger than 20pF to SETI.
4 4 OUT Switch Output. Bypass OUT with a 1μF capacitor to GND.
5 5 IN
Power Input. Bypass IN with a F ceramic capacitor to GND. Use higher
capacitance if necessary to prevent large load transients from pulling down the
supply voltage.
7 ON Active-Low, Switch-ON Input. Drive ON low to turn on the switch.
7 ON Active-High, Switch-ON Input. Drive ON high to turn on the switch.
8 8 GND Ground
— — EP
Exposed Pad. Internally connected to GND. For enhanced thermal dissipation,
connect EP to a large copper ground plane. Do not use EP as the sole ground
connection.
MAX14523A/MAX14523AL/MAX14523B/MAX14523C
250mA to 1.5A, Adjustable
Current-Limit Switches
8 _______________________________________________________________________________________
Functional Diagram
MAX14523A
MAX14523AL
MAX14523B
MAX14523C
BUFFER
IN
N.C.
THERMAL
SHUTDOWN
CONTROL
LOGIC
REVERSE-
CURRENT
PROTECTION
TIMING
CIRCUITRY
BUFFER
CURRENT
LIMIT
BANDGAP
REFERENCE
OUT
FLAG
SETI
*( ) FOR THE MAX14523AL ONLY
ON/(ON)*
GND
Detailed Description
The MAX14523A/MAX14523AL/MAX14523B/MAX14523C
programmable current-limit switches operate from
+1.7V to +5.5V and provide internal current limiting
adjustable from 250mA to 1.5A. These devices feature
a fixed blanking time, and a FLAG output that notifies
the processor when a fault condition is present.
Programmable Current Limit/Threshold
A resistor from SETI to GND sets the current
limit/threshold for the switch (see the
Setting the
Current Limit/Threshold
section). If the output current is
limited at the current threshold value for a time equal to
or longer than t
BLANK
, the output flag asserts and the
MAX14523A/MAX14523AL enter the autoretry mode,
the MAX14523B latches off the switch, and the
MAX14523C enters the continuous current-limit mode.
Autoretry (MAX14523A/MAX14523AL)
When the forward current reaches the current thresh-
old, the t
BLANK
timer begins counting (Figure 2). FLAG
asserts if the overcurrent condition is present for
t
BLANK
or longer. The timer resets if the overcurrent
condition disappears before the blanking time (t
BLANK
)
has elapsed. A retry time delay (t
RETRY
) starts immedi-
ately after the blanking time has elapsed. During that
time, the switch latches off. At the end of t
RETRY
, the
switch turns on again. If the fault still exists, the cycle
repeats. If the fault has been removed, the switch stays
on. During this cycle, FLAG stays low. In autoretry, if
the die temperature exceeds +170°C (typ) due to self
heating, the MAX14523A/MAX14523AL go into thermal
shutdown until the die temperature drops by approxi-
mately 15°C (see the
Thermal Shutdown
section.)
MAX14523A/MAX14523AL/MAX14523B/MAX14523C
250mA to 1.5A, Adjustable
Current-Limit Switches
_______________________________________________________________________________________ 9
The autoretry feature saves system power in case of an
overcurrent or short-circuit condition. During t
BLANK
time, when the switch is on, the supply current is held
at the current limit. During time t
RETRY
, when the switch
is off, the current through the switch is zero. Thus, the
average output current is much less than the pro-
grammed current limit. Calculate the average output
current using the following equation:
I
LOAD
= I
LIM
[(t
BLANK
)/(t
BLANK
+ t
RETRY
)]
With a typical t
BLANK
= 17.5ms and typical t
RETRY
=
560ms, the duty cycle is 3%, resulting in a 97% power
savings over the switch being on the entire time.
Latchoff (MAX14523B)
When the forward current reaches the current thresh-
old, the t
BLANK
timer begins counting (Figure 3). FLAG
asserts if an overcurrent condition is present for greater
than t
BLANK
time. The timer resets if the overcurrent
condition disappears before t
BLANK
has elapsed.
The switch turns off if the overcurrent condition contin-
ues beyond the blanking time. Reset the switch by
either toggling the control logic (ON or ON) or cycling
the input voltage. If the die temperature exceeds
+170°C (typ) due to self heating, the MAX14523B goes
into thermal shutdown until the die temperature
drops by approximately 15°C (see the
Thermal
Shutdown
section).
Continuous Current Limit (MAX14523C)
When the forward current reaches the forward-current
threshold, the MAX14523C limits the output current to
the programmed current limit. FLAG asserts if the cur-
rent limit is present for t
BLANK
and deasserts when the
overload condition is removed. In this mode, if die tem-
perature exceeds +170°C (typ) due to self heating, the
MAX14523C goes into thermal shutdown until the die
temperature drops by approximately 15°C (see the
Thermal Shutdown
section).
Switch-On/Off Control
The ON input for the MAX14523A/MAX14523B/
MAX14523C and ON input for the MAX14523AL control
the switch, see Table 1. Toggle ON for the MAX14523B
to reset the fault condition once the short-circuit current
is detected and the device shuts down.
Reverse-Current Protection
The MAX14523A/MAX14523AL/MAX14523B/MAX14523C
feature a reverse-current protection circuit that limits
the backflow current to 2µA when the reverse-current
protection circuitry has tripped. The switch turns off and
FLAG asserts without waiting for t
BLANK
to elapse. The
switch turns back on and FLAG deasserts when V
IN
-
V
OUT
drops below the reverse-current threshold by
95mV (typ).
FLAG Indicator
FLAG is an open-drain fault indicator output and
requires an external pullup resistor to a DC supply.
FLAG goes low when any of the following conditions
occur:
The blanking time has elapsed
The reverse-current protection has tripped
The die temperature exceeds +170°C
SETI is connected to ground.
Thermal Shutdown
Thermal-shutdown circuitry protects the devices from
overheating. The switch turns off and FLAG goes low
immediately when the junction temperature exceeds
+170°C (typ). The switch turns on again after the
device temperature drops by approximately 15°C (typ).
Applications Information
Setting the Current Limit/Threshold
A resistor from SETI to ground programs the current
limit/threshold value for the MAX14523A/MAX14523AL/
MAX14523B/MAX14523C. Table 2 lists various current
limit/thresholds set by different resistor values at SETI.
Leaving SETI unconnected selects a 0 current
limit/threshold. Connecting SETI to ground asserts
FLAG.
Use the following formula to calculate the current limit:
Rk
V
ImA
k
SETI
LIM
()
()
()
.( )ΩΩ=−
141400
248
MAX14523A
MAX14523B
MAX14523C
MAX14523AL
ON ON
SWITCH STATUS
0 1 Off
1 0 On
Table 1. Switch Truth Table

MAX14523CATA+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Power Switch ICs - Power Distribution Adjustable Current Limit Switch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet