0JLS600.X

© 2016 Littelfuse POWR-GARD
®
Productswww.littelfuse.com
Rev: 120716
1 of 2
POWR-GARD
®
Fuse Datasheet
CLASS J – JLS SERIES FUSES
600 VAC • Fast-Acting • 1-600 A
AMPERE RATINGS
1 20 45 90 175 350
3 25 50 100 200 400
6 30 60 110 225 450
10 35 70 125 250 500
15 40 80 150 300 600
Description
The UL Listed Class J JLS Series fuses provide space
saving, fast-acting overload and short-circuit protection for
vital industrial and power conversion applications.
Littelfuses JLS Series fuses offer best in class current
limitation that prevents equipment damage from overcurrent
faults.
Features and Benefits
Superior performance in a space saving package
Reliable interruption of all overcurrents with protection
up to 200kA
Extremely current limiting
Fast-acting protection for surge-sensitive devices and
components
Reduces heating and magnetic effects due to
overcurrents, extending equipment life
Economical and readily available
Applications
Power conversion device protection
Variable speed drives
Rectifiers
Resistive loads
Solid-state devices
10000
100000
200000
100
1000
100
1000
10000
100000
1000000
600 A
400 A
200 A
100 A
60 A
30 A
PEAK LET-THRU IN AMPERES
AVAILABLE FAULT CURRENT
SYMMETRICAL R. M. S. AMPERES
05567005
SERIES AMPERAGE
CATALOG
NUMBER
ORDERING
NUMBER
JLS 110 JLS110 0JLS110.X
Ordering Information
Dimensions
Please refer to the Class J dimensions on page 2
Web Resources
Download TC curves, CAD drawings and other technical
information: littelfuse.com/jls
Recommended Fuse Holders
LFJ60 Series
LFPSJ Series (
8
10
60 A)
QP
L
JLS
Peak Let-Thru Curve
Specifications
Voltage Ratings 600 VAC
Interrupting Ratings 200 kA rms symmetrical
Ampere Range 1–600 A
Approvals Standard 248-8, Class J
UL Listed (File: E81895)
CSA Certified (File: LR29862)
Federal Specification WF-1814
(QPL-W-F-1814)
© 2016 Littelfuse POWR-GARD
®
Productswww.littelfuse.com
Rev: 120716
2 of 2
POWR-GARD
®
Fuse Datasheet
CLASS J DIMENSIONS AND CURRENT-LIMITING EFFECTS
A
C
D
G
F
E
H
A
B
C
D
Fig. 1
Fig. 2
Dimensions Inches (mm)
AMPERES
REFER TO
FIG. NO.
DIMENSIONS INCHES (mm)
A B C D E F G H
1 – 30 1 2
1
4
(57.2)
1
2
(12.7)
13
16
(20.6)
35 – 60 1 2
3
8
(60.3)
5
8
(15.9) 1
1
16
(27.0)
70 – 100 2 2
5
8
(66.7) 3
17
32
(89.7) 3
23
32
(94.5) 4
5
8
(117.5) 1 (25.4)
3
4
(19.1)
9
32
(7.1)
1
8
(3.2)
110 – 200 2 3 (76.2) 4
9
32
(108.7) 4
15
32
(113.5) 5
3
4
(14 6.1) 1
1
2
(38.1) 1
1
8
(28.6)
9
32
(7.1)
3
16
(4.8)
225 – 400 2 3
3
8
(85.7) 5
1
8
(130.2) 5
3
8
(136.5) 7
1
8
(181.0) 2 (50.8) 1
5
8
(41.3)
13
32
(10.3)
1
4
(6.4)
450 – 600 2 3
3
4
(95.3) 5
27
32
(148.4) 6
5
32
(156.4) 8 (203.2) 2
1
2
(63.5) 2 (50.8)
17
32
(13.5)
3
8
(9.5)
Dimensions
Current-Limiting Effects of JTD_ID (600 V) Fuses
SHORT CIRCUIT
CURRENT
APPARENT RMS SYM MET RI CAL CURRENT FOR VARIOUS FUSE RATINGS
15 A 30 A 60 A 100 A 200 A 400 A 600 A
5,000 565 750 1,500 1,800 2,800 4,800 5,000
10,000 675 925 1,900 2,450 3,600 5,700 7,75 0
15,000 775 1,050 2,100 2,800 4,100 6,500 9,000
20,000 825 1,125 2,300 3,000 4,400 7,25 0 9,700
25,000 900 1,200 2,500 3,300 5,000 8,000 10,500
30,000 950 1,300 2,600 3,500 5,100 8,400 11,000
35,000 1,000 1,350 2,700 3,700 5,400 9,000 12,000
40,000 1,050 1,400 2,800 3,900 5,600 9,200 12,500
50,000 1,100 1,500 3,000 4,200 6,000 10,000 13,000
60,000 1,200 1,600 3,200 4,500 6,400 10,500 14,000
80,000 1,300 1,700 3,400 4,900 7,2 0 0 11,200 15,500
100,000 1,375 1,800 3,600 5,200 7,80 0 12,200 16,500
150,000 1,500 2,000 3,950 6,000 9,000 14,500 19,000
200,000 1,600 2,175 4,000 6,500 10,000 16,000 20,500
†Prospective RMS Symmetrical Amperes Short-Circuit Current
Note: Data derived from Peak Let-Thru Curves