SPECIFICATION
150W Constant Voltage + Constant Current LED Driver
HLG-150H series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A/AB-Type only (via built-in potentiometer)
Adjustable for A/AB-Type only (via built-in potentiometer)
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55032 (CISPR32) Class B, EN61000-3-2 Class C ; EN61000-3-3(@ load 60%)≧ ,
GB17743 and GB17625.1, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level ( ), EAC TP TC 020surge immunity Line-Earth 4KV, Line-Line 2KV
Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
192.2K hrs min. MIL-HDBK-217F (25 )℃
228*68*38.8mm
1.15Kg; 12pcs/14.8Kg/0.8CUFT
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
14 ~ 17V 18 ~ 21V
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
54 ~ 63V
47 ~ 53V 59 ~ 65V
91.5%
92%
93%
93%
93.5%
93.5%
94%94% 94%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0%
±1.0%
±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
HLG-150H-12
HLG-150H-15
HLG-150H-20
HLG-150H-24
HLG-150H-30
HLG-150H-36
HLG-150H-48
12V 15V 20V 24V 30V
36V
48V
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V10.8 ~ 13.5V
HLG-150H-54
54V
200mVp-p
49 ~ 58V
HLG-150H-42
42V
200mVp-p
38 ~ 46V
7.5 ~ 12.5A 6 ~ 10A 4.5 ~ 7.5A 3.8 ~ 6.3A 3 ~ 5A
2.5 ~ 4.2A
1.92 ~ 3.2A 1.68 ~ 2.8A
2.16 ~ 3.6A
12.5A 10A 7.5A 6.3A
5A
4.2A
3.2A
150W 150W 150W 151.2W 150W
151.2W
153.6W
2.8A
151.2W
3.6A
151.2W
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
Shut down o/p voltage with auto-recovery or re-power on to recovery
EMC IMMUNITY
EMC EMISSION
UL8750(type”HL”), CSA C22.2 No. 250.0-08; 61347-1, 61347-2-13 independent;GB19510.1, GB19510.14;EN/AS/NZS EN/AS/NZS
IP65 or IP67; J61347-1, J61347-2-13, ( for 12B,24B,36A,54A only), EAC TP TC 004 approved ;BIS IS15885
COLD START 65A(t =425 s measured at 50% I ) at 230VAC;width peak Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
CONSTANT CURRENT REGION
Note.4
6 ~12V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V
18 ~ 36V
24 ~ 48V 27 ~ 54V
21 ~ 42V
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
16ms / 115VAC, 230VAC
1000ms,200ms/115VAC 500ms,200ms/230VAC
μ
PF 0.98/115VAC, PF 0.95/230VAC, PF 0.92/277VAC @ full load≧≧≧
(Please refer to " " section)POWER FACTOR (PF) CHARACTERISTIC
THD< 20% (@ load 60% / 115VAC,230VAC; @ load 75% / 277VAC)≧≧
(Please refer to TOTAL HARMONIC DISTORTION (THD) section)""
MAX. CASE TEMP.
Tcase= +90℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. driver
The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently
driver
connected to the mains.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:HLG-150H-SPEC 2018-05-29
Design refer to UL60950-1, TUV EN60950-1