VI-RUR22-EWXX

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FlatPAC Rev. 1.5 Page 1 of 6
Set your site on VICOR at vicorpower.com
0
1 1 E U U U
Configuration Chart
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95 Vdc
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40 ms ride-through time
OVP and thermal shutdown
1 output; up to 200 W
1 or 2 outputs; up to 400 W
1, 2, or 3 outputs; up to 600 W
Product Highlights
If you’re looking for the convenience
of a complete, low profile, agency-
approved switching power supply, look
no further. The FlatPAC combines Vicors
workhorse VI-200 family of DC-DC
converters with a modular package and
front-end subassembly to provide from
50 to 600 W of output power from one
to three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the model
number.
Vicors FlatPAC is also available with a
current controlled output using BatMod
converter modules of 12, 24, or 48 Vdc
outputs. This option is specified by
appending “BM” or “BC” (for conduction
cooled versions) to the end of the FlatPAC
model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
The FlatPAC’s contemporary design
allows us to configure your order quickly
and provide rapid turnaround on standard
models. It is truly a complete power
solution, enabling you to spend more time
designing your system and less time
worrying about how to power it.
Data Sheet
FlatPAC
TM
50 to 600 Watts Autoranging
AC-DC Switchers
Substitute VE for VI for RoHS compliant versions
Configuration Total # of
Power Converters Dimensions
Single Output
VI-LU - 50 – 200 W 1
9.25" x 2.5" x 1.37"
(234,8 x 124,5 x 34,8 mm)
VI-MU - 200 – 400 W 2
9.25" x 4.9" x 1.37"
(234,8 x 124,5 x 34,8 mm)
VI-NU - 300 – 600 W 3
9.25" x 7.3" x 1.37"
(234,8 x 185,4 x 34,8 mm)
Dual Output
VI-PU - 100 – 400 W 2
9.25" x 4.9" x 1.37"
(234,8 x 124,5 x 34,8 mm)
VI-QU - 150 – 600 W 3
9.25" x 7.3" x 1.37"
(234,8 x 185,4 x 34,8 mm)
Triple Output
VI-RU - 150 – 600 W 3
9.25" x 7.3" 1.37"
(234,8 x 185,4 x 34,8 mm)
Typical Model: VI-RU - -
Input Output Input Characteristics
115/230 Vac 1: 5 Vdc at 200 W 90132/180264 Vac
2: 12 Vdc at 200 W U = Autoranging
3: 12 Vdc at 200 W
Z = 2 V
Y = 3.3 V
0 = 5 V
X = 5.2 V
W = 5.5 V
V = 5.8 V
T = 6.5 V
R = 7.5 V
M = 10 V
1 = 12 V
P = 13.8 V
2 = 15 V
N = 18.5 V
3 = 24 V
L = 28 V
J = 36 V
K = 40 V
4 = 48 V
H = 52 V
F = 72 V
D = 85 V
B = 95 V
Output Voltage
Grade Operating Storage
E = 0 to +85 –20 to +100
C = 0 to +85 –20 to +100
I = 30 to +85 –55 to +100
Temperatures apply to product case.
Product Grade Temps. °C
V
OUT
≥5 V V
OUT
< 5 V
Y = 50 W Y = 10 A
X = 75 W X = 15 A
W = 100 W W = 20 A
V = 150 W V = 30 A
U = 200 W U = 40 A
Output Power/Current
VOUT ≥5 V VOUT < 5 V
W= 100 W W= 20 A
V = 150 W V = 30 A
U = 200 W U = 40 A
S = 300 W S = 60 A
Q = 400 W Q = 80 A
Output Power/Current
VOUT ≥5 V VOUT < 5 V
S = 300 W S = 60 A
P = 450 W P = 90 A
M = 600 W M = 120 A
Output Power/Current
BC = BatMod/Conduction Cooled BM = BatMod CC = Conduction Cooled
Options
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FlatPAC Rev. 1.5 Page 2 of 6
Set your site on VICOR at vicorpower.com
INPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC line input
Autoranging 90 – 132/180 – 264 Vac
Line frequency
47 – 63 Hz (C-Grade and E-Grade)
47 – 440 Hz (I-Grade)
Inrush current: 115 Vac operation:
1 converter 16 A @ peak line
2 converters 23 A @ peak line
3 converters 39 A @ peak line
Inrush current: 230 Vac operation
1 converter 32 A @ peak line
2 converters 47 A @ peak line
3 converters 78 A @ peak line
Ride-through time (full load)
90/180 Vac low line 5 ms minimum
115/230 Vac nominal line 40 ms minimum
AC fail warning time 5 ms minimum (low line, full load)
AC and BUS OK (2 and 3 converter models only)
Off state – Vce 70 V
On state – Vcesat 0.4 V @ 1 mA (1.5 mA max.)
Module disable (2 and 3 converter models only, optically isolated LED input)
Continuous forward current 1 – 30 mA
Forward voltage 1.65 V @ 30 mA
Dielectric withstand
Primary to chassis GND 2,121 Vdc
Primary to secondary 4,242 Vdc
Secondary to chassis GND 707 Vdc
SPECIFICATIONS
(typical at 25°C, nominal line and 75% load, unless otherwise specified)
E-Grade C-, I-Grade
Parameter Min Typ Max Min Typ Max Unit Notes
Set point accuracy 1% 2% 0.5% 1% VNOM
Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load
1% 0.2% 0.5% VNOM LL to HL, No Load to full load
Output temperature drift 0.02 0.01 0.02 %/°C Over rated temperature
Long term drift 0.02 0.02 %/1 k hours
Output ripple
2 V 150 mV 60 mV 100 mV p-p 20 MHz bandwidth
5 V 5% 2% 3% p-p 20 MHz bandwidth
10 – 48 V 3% 0.75% 1.5% p-p 20 MHz bandwidth
Output voltage trimming
1
50% 110% 50% 110%
Total remote sense
compensation 0.5 0.5 Volts 0.25 V max. neg. leg
OVP set point 125% 115% 125% 135% VNOM Recycle power
Current limit 105% 135% 105% 125% INOM Automatic restart
Short circuit current
2
20% 140% 20% 130% INOM
OUTPUT SPECIFICATIONS
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FlatPAC Rev. 1.5 Page 3 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS (CONT.)
E-Grade C-, I- Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Efficiency 78 – 88% 80 – 90% @5 V and higher
Shut down temp. — case 90 95 105 90 95 105 °C
Cool and recycle power
to restart
Operating temp. — case 85 85 °C See Thermal Curves
THERMAL CHARACTERISTICS
E-Grade C-, I- Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Weight
3
22.4 22.4 Ounces
(652) (652) (Grams)
MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
Safety Standards Markings Notes
UL1604, UL60950-1 cURus
UL / CSA / EN / IEC 60950-1 cTÜVus,
CE Mark Low Voltage Directive (73/23/EEC)
1
10 V, 12 V and 15 V outputs, trim range ± 10%. Consult factory for wider trim range.
2
Output voltages of 5 V or less incorporate foldback current limiting, outputs greater than 5 V incorporate straight line current limiting.
3
For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3.
EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.)
Parameter Notes
Conducted emissions, LISN EN 55022 and FCC R&R, Part 15, Subpart B, Class B
Radiated emissions, 10 meters EN 55022; 1998 and FCC R&R, Part 15, Subpart B, Class A
Electrostatic discharge IEC 61000-4-2: 1995, Level 4; ±8 kV Contact, ± 15 kV Air Discharge
RF radiated immunity, E-field IEC 61000-4-3: 1997; 80 MHz to 1.0 GHz, 3 V/M, CW
Electrical fast transients/burst EN 61000-4-4: 1995, Level 3; ±2 kV,
Surge immunity EN 61000-4-5: 1996 Class 3; ±2 kV Line to Ground, ±1 kV Line to Line
RF conducted immunity IEC 61000-4-6: 1996, class 3, 10 Vrms, 150 kHz to 80 MHz
Power frequency magnetic
IEC 61000-4-8: 1994, 30 to 300 A/M, 50Hz
field immunity
Voltage dips and interrupts IEC 61000-4-11: 1994

VI-RUR22-EWXX