Electrical specifications VNQ5E250AJ-E
10/37 Doc ID 17360 Rev 3
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
=1mA 5.5 7 V
I
IN
=-1mA -0.7 V
V
CSDL
CS_DIS low level voltage 0.9 V
I
CSDL
Low level CS_DIS current V
CSD
=0.9V 1 µA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
=2.1V 10 µA
V
CSD(hyst)
CS_DIS hysteresis voltage 0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
=1mA 5.5 7 V
I
CSD
=-1mA -0.7 V
Table 8. Protections and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
=13V 3.5 5 7 A
4.5 V < V
CC
<28V 7 A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V; T
R
<T
j
<T
TSD
1.25 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1
T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 0.5 A; V
IN
=0;
L=20mH
V
CC
-41
V
CC
-46 V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
=0.015;
T
j
= -40 °C...150 °C
(see Figure 8)
25 mV