Electrical specifications VNQ5E250AJ-E
10/37 Doc ID 17360 Rev 3
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
=1mA 5.5 7 V
I
IN
=-1mA -0.7 V
V
CSDL
CS_DIS low level voltage 0.9 V
I
CSDL
Low level CS_DIS current V
CSD
=0.9V 1 µA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
=2.1V 10 µA
V
CSD(hyst)
CS_DIS hysteresis voltage 0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
=1mA 5.5 7 V
I
CSD
=-1mA -0.7 V
Table 8. Protections and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
=13V 3.5 5 7 A
4.5 V < V
CC
<28V 7 A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V; T
R
<T
j
<T
TSD
1.25 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1
T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 0.5 A; V
IN
=0;
L=20mH
V
CC
-41
V
CC
-46 V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
=0.015;
T
j
= -40 °C...150 °C
(see Figure 8)
25 mV
VNQ5E250AJ-E Electrical specifications
Doc ID 17360 Rev 3 11/37
Table 9. Current sense (8 V < V
CC
<18V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
K
0
I
OUT
/I
SENSE
I
OUT
= 0.025 A;V
SENSE
=0.5V
T
j
= -40 °C...150 °C 295 500 705
K
1
I
OUT
/I
SENSE
I
OUT
= 0.25 A;V
SENSE
=0.5V
T
j
= -40 °C...150 °C
T
j
= 25 °C...150 °C
360
395
470
470
595
568
dK
1
/K
1
(1)
Current sense ratio drift
I
OUT
= 0.25 A;V
SENSE
=4V
T
j
= -40 °C...150 °C
-9 +9 %
K
2
I
OUT
/I
SENSE
I
OUT
= 0.5 A;V
SENSE
=4V
T
j
= -40 °C...150 °C
T
j
= 25 °C...150 °C
425
445
485
485
555
540
dK
2
/K
2
(1)
Current sense ratio drift
I
OUT
= 0.5 A; V
SENSE
=4V
T
j
= -40 °C...150 °C
-6 +6 %
K
3
I
OUT
/I
SENSE
I
OUT
= 1 A; V
SENSE
=4V
T
j
= -40 °C...150 °C
T
j
= 25 °C...150 °C
465
475
500
500
535
525
dK
3
/K
3
(1)
Current sense ratio drift
I
OUT
= 1 A; V
SENSE
=4V
T
j
= -40 °C...150 °C
-4 +4 %
I
SENSE0
Analog sense leakage
current
I
OUT
= 0 A; V
SENSE
=0V;
V
CSD
=5V; V
IN
=0V;
T
j
= -40 °C...150 °C
01µA
V
CSD
=0V; V
IN
=5V;
T
j
= -40 °C...150 °C
02µA
I
OUT
= 0.5 A; V
SENSE
=0V;
V
CSD
=5V; V
IN
=5V;
T
j
= -40 °C...150 °C
01µA
I
OL
Openload ON-state
current
detectionthreshold
V
IN
= 5V; 8V<V
CC
<18V;
I
SENSE
= 5 µA
0.5 5 mA
V
SENSE
Max analog sense
output voltage
I
OUT
= 0.5 A; V
CSD
=0V;
R
SENSE
=10KΩ
5V
V
SENSEH
Analog sense output
voltage in fault
condition
(2)
V
CC
= 13 V; R
SENSE
= 3.9 KΩ 8
V
V
CC
= 5 V; R
SENSE
= 3.9 KΩ 4.5
I
SENSEH
Analog sense output
current in fault
condition
(2)
V
CC
=13V; V
SENSE
=5V 9
mA
V
CC
=5V; V
SENSE
=3.5V 6
t
DSENSE1H
Delay response time
from falling edge of
CS_DIS pin
V
SENSE
<4V;
0.025 A <I
OUT
< 1 A;
4.5 V < V
CC
<18V;
I
SENSE
=90% of I
SENSE
max
(see Figure 4)
40 100 µs
Electrical specifications VNQ5E250AJ-E
12/37 Doc ID 17360 Rev 3
t
DSENSE1L
Delay response time
from rising edge of
CS_DIS pin
V
SENSE
<4V;
0.025 A < I
OUT
< 1 A;
4.5 V < V
CC
<18V;
I
SENSE
=10 % of I
SENSE
max
(see Figure 4)
520µs
t
DSENSE2H
Delay response time
from rising edge of
INPUT pin
V
SENSE
<4V;
0.025A < I
OUT
< 1 A;
4.5 V < V
CC
<18V;
I
SENSE
=90% of I
SENSE
max
(see Figure 4)
50 200 µs
Δt
DSEN
SE
2H
Delay response time
between rising edge of
output current and rising
edge of current sense
V
SENSE
<4V;
I
SENSE
=90% of I
SENSEMAX
;
4.5 V < V
CC
<18V;
I
OUT
=90% of I
OUTMAX
I
OUTMAX
= 1.5 A (see Figure 7)
110 µs
t
DSENSE2L
Delay response time
from falling edge of
INPUT pin
V
SENSE
<4V;
0.025A < I
OUT
< 1 A;
4.5 V < V
CC
<18V;
I
SENSE
=10% of I
SENSE
max
(see Figure 4)
15 150 µs
1. Parameter guaranteed by design; it is not tested.
2. Fault condition includes: power limitation, overtemperature and open load OFF-state detection.
Table 10. Open-load detection (8 V < V
CC
<18V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
OL
Open-load off-state voltage
detection threshold
V
IN
= 0 V; 4.5 V < V
CC
<18V 2 - 4 V
t
DSTKON
Output short circuit to V
CC
detection delay at turn-off
See Figure 5 180 - 1200 µs
I
L(off2)
Off-state output current at
V
OUT
= 4 V
V
IN
=0V; V
SENSE
=0V
V
OUT
rising from 0 V to 4 V
-120 - 0 µA
td_vol
Delay response from output
rising edge to V
SENSE
rising
edge in open-load
V
OUT
= 4 V; V
IN
= 0 V
V
SENSE
= 90% of V
SENSEH
-20µs
Table 9. Current sense (8 V < V
CC
< 18 V) (continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit

VNQ5E250AJ-E

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Motor / Motion / Ignition Controllers & Drivers 41V Quad High Side 4 to 28V 250mOhm 5A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet