B57703M0502A004

NTC Thermistor B57703M0502A004
NTC Probes M703/5k/2%
Data sheet
KB S PE 2007-10-02
Please read Cautions and warnings and Page 4 of 6
Important notes at the end of this document.
Cautions and warnings
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature -25°C …+45°C,
relative humidity 75% annual mean, maximum 95%, dew precipitation is inadmissible.
Do not store thermistors where they are exposed to heat or direct sunlight. Otherwise, the packing
material may be deformed or components may stick together, causing problems during mounting.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environments like corrosive gases (Sox, Cl etc.)
After opening the factory seals, such as polyvinyl-sealed packages, use the components as soon
as possible.
Solder thermistors after shipment from EPCOS within the time specified:
Leaded components: 24 months
Handling
NTC thermistors must not be dropped. Chip-offs must not be caused during handling of NTCs.
Components should not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering
Use resin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
NTC Thermistor B57703M0502A004
NTC Probes M703/5k/2%
Data sheet
KB S PE 2007-10-02
Please read Cautions and warnings and Page 5 of 6
Important notes at the end of this document.
Mounting
When thermistors are sealed, potted or overmolded, there must be no mechanical stress caused
by thermal expansion during the production process (curing/overmolding process) and during later
operation. The upper category temperature of the thermistor must not be exceeded. Ensure that
the materials used (sealing/potting compound and plastic material) are chemically neutral.
Electrodes/contacts must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting.
During operation, the thermistor´s surface temperature can be very high (ICL). Ensure that
adjacent components are placed at a sufficient distance from the thermistor to allow for proper
cooling of the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can withstand
the temperature.
Make sure that thermistors (ICLs) are adequately ventilated to avoid overheating.
Avoid contamination of thermistor surface during processing.
During mounting and operation tensile forces on the leads are to be avoided.
Bending or twisting of the leads directly on the thermistor body is not permissible.
Operation
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified voltage and current ranges (ICLs).
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be ensured
that no water enters the NTC thermistors (e.g. through plug terminals). For measurement
purposes (checking the specified resistance vs. temperature), the component must not be
immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation unless thermistor is specified for these conditions.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage caused
by malfunction (e.g. use VDR for limitation of overvoltage condition).
Important notes B57703M0502A004
NTC Probes M703/5k/2%
KB S PE 2007-10-02
Please read Cautions and warnings and Page 6 of 6
Important notes at the end of this document.
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g. installation
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap,
SIMID, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered or
pending in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.

B57703M0502A004

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
NTC Thermistors 5k 3988 1% 150mW
Lifecycle:
New from this manufacturer.
Delivery: