2
PS8800 12/07/05
PI5A4213
Low Voltage Dual SP3T Analog Switch
3:1 Mux/DeMux Bus Switch
Recommended Operating Conditions
(3)
Supply Voltage Operating (V
CC
) . . . . . . . . . . . . 1.65V to 5.5V
Control Input Voltage (V
IN
) . . . . . . . . . . . . . . . . . . . 0V to V
CC
Switch Input Voltage (V
IN
). . . . . . . . . . . . . . . . . . . . 0V to V
CC
Output Voltage (V
OUT
) . . . . . . . . . . . . . . . . . . . . . . . 0V to V
CC
Operating Temperature (T
A
) . . . . . . . . . . . . . . . –40°C to +85°C
Input Rise and Fall Time (t
r
,t
f
)
Control Input V
CC
= 2.3V - 3.6V. . . . . . . . . 0ns/V to 10ns/V
Control Input V
CC
= 4.5V - 5.5V. . . . . . . . . . 0ns/V to 5ns/V
Thermal Resistance (θ
JA
) . . . . . . . . . . . . . . . . . . . . . . 350°C/W
Absolute Maximum Ratings
(1)
Supply Voltage V
CC
............................................ –0.5V to +7V
DC Switch Voltage (V
S
)
(2)
........................ –0.5V to V
CC
+0.5V
DC Input Voltage (V
IN
)
(2)
................................ –0.5V to +7.0V
DC Output Current (V
OUT
) ........................................... 128mA
DC V
CC
or Ground Current (I
CC
/I
GND
)
....................... ±100mA
Storage Temperature Range (T
STG
) .............. –65°C to +150°C
Junction Temperature under Bias (T
J
) .............................150°C
Junction Lead Temperature (T
L
)
(Soldering, 10 seconds) ................................................260°C
Power Dissipation (P
D
) @ +85°C .................................. 180mW
Notes:
1. Absolute Maximum Ratings may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any
other conditions beyond those indicated in the operational sections of this specication is not implied.
2. The input and output negative voltage ratings may be exceeded if the inut and output diode current ratings are observed.
3. Control input must be held HIGH or LOW; it must not oat.