RAC04-3.3SC/230

4 Watt
Single &
Dual Output
Universal Input 80-264VAC
100mW max No load Power Consumption
Efficiency up to 79%
High Operating Temperature Range
(-40°C to +80°C)
Isolated Output 3.75kVAC / 1 min
Continuous Short Circuit Protection
Meet EN55022 Class B
EN, UL and CE Certified
Features
Regulated
Converters
Selection Guide
Description
Input Voltage Range (with Derating) 80-264VAC or 113-373VDC
Input Frequency 47-440Hz
Input Current (Full Load) 115VAC/230VAC 98mA / 64mA max.
Inrush Current 115VAC/230VAC 15A / 30A max.
No Load Power Consumption 115VAC/230VAC 50/60Hz 100mW max.
Output Voltage Accuracy (Full Load) Single Outputs ±2% typ.
Dual Outputs ±2% typ.
5V / 12V ±2% / ±10% typ.
Line Voltage Regulation (90-264VAC) Single Outputs ±0.2% typ.
Dual Outputs ±0.2% typ.
5V / 12V ±0.2% / ±1% typ.
Load Voltage Regulation 3.3V/5V Output ±1% typ.
(10% - 100% load) All Others ±0.5% typ.
5V / 12V ±1% / ±5% typ.
Output Ripple&Noise 200mVp-p typ.
(measured @ 20MHz of bandwidth with 0.1μF & 47μF parallel capacitors)
Switching Frequency (Full Load) 67kHz typ.
Hold-Up Time 115VAC 15ms min.
Minimum Load 0%
Isolation Voltage Input-Output 3.75kVAC / 1minute
Leakage Current 230VAC / 50Hz 0.25mA max.
Isolation Resistance 100M Ω min.
continued on next page
Specifications
(measured at TA 25°C, full load after warm-up)
POWERLINE
AC/DC-Converter
with 3 year Warranty
EN-60950-1 certified
UL-60950-1 certified
RAC04-C/230
100
60
40
20
0
80
Ambient Temperature Range (°C)
-40 0-20 20 40
65
Load (%)
Safe Operating Area
60
80
50
Part Input Output Output Efficiency Max.
Number Voltage Voltage Current (Typ.) Capacitive
(VAC) (VDC) (mA) (%) Load**
RAC04-3.3SC/230 80-264 3.3 1200 72 10000μF
RAC04-05SC/230 80-264 5 800 75 7200μF
RAC04-12SC/230 80-264 12 333 77 1000μF
RAC04-15SC/230 80-264 15 267 78 820μF
RAC04-24SC/230 80-264 24 167 79 220μF
RAC04-0512DC/230 80-264 5/12 720/33 75 4700/100μF
RAC04-05DC/230 80-264 ±5 ±400 76 ±3300μF
RAC04-12DC/230 80-264 ±12 ±166 78 ±680μF
** measured @115VAC
E224736
RoHS
2011/65/EU
6/6
The RAC04-C/230 series are fully certified single and dual regulated
AC/DC converters in an encapsulated PCB-mount package style with
3.75kVAC isolation and very low standby power consumption. The
converters have SC protected single as well as dual outputs and meet
EN55022 class B without any external components. Uses include
board-level power supplies, home automation, instrumentation
systems and standby applications.
Derating-Graph
(Ambient Temperature)
PA-20 www.recom-power.comREV: 0/2015
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
RAC04-
C/230
Specifications
(measured at TA 25°C, full load after warm-up)
Load (%)
Efficiency (%)
0
0
10
20
30
40
50
60
70
80
90
10 20 30 40 50 60 70 80 90 100
3.3SC
05SC
12SC
24SC
15SC
Load (%)
Efficiency (%)
0
0
10
20
30
40
50
60
70
80
90
10 20 30 40 50 60 70 80 90 100
05DC
12DC
0512DC
Single Output 115VAC Dual Output 115VAC
Load (%)
Efficiency (%)
0
0
10
20
30
40
50
60
70
80
90
10 20 30 40 50 60 70 80 90 100
3.3SC
05SC
12SC
24SC
15SC
Load (%)
Efficiency (%)
0
0
10
20
30
40
50
60
70
80
90
10 20 30 40 50 60 70 80 90 100
05DC
12DC
0512DC
Single Output 230VAC Dual Output 230VAC
Short Circuit Protection Auto Recovery
Over Voltage Category OVC II
Operating Temperature Range -40°C to +65°C (without Derating)
Natural Convection -40°C to +80°C (with Derating)
Storage Temperature Range -40°C to +100°C
Case Material UL94V-0 Black Plastic
Relative Humidity Non-condensing 95% RH max.
Package Weight 31.5g typ.
Dimension (L x W x H) 36.7 x 27.2 x 17.1mm
EMC Conducted and Radiated EN55022 Class B
Noise Immunity EN55024
MTBF (+25°C) MIL-HDBK-217F 500 x 10³ hours
Certification CE EN55022 Class B
UL General Safety Report: E224736 UL60950-1, 2nd Edition
EN General Safety Report: 131055-1CB-M1 EN60950-1, 2006, 2nd Edition + A12:2012
CB General Safety Report: 131055-1CB-M1 IEC 60950-1: 2005; 2nd Edition
Efficiency vs Load
www.recom-power.com PA-21REV: 0/2015
RAC04-
C/230
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
Specifications
(measured at TA 25°C, full load after warm-up)
Load
VAC (L)
VAC (N)
Vout-
Vout+
L
N
Fuse 1A
47uF/50V
0.1uF/50V
Application Note:
1. Recommended external input fuse 1A/slow blow type.
2. To measure the output ripple & noise connect 0.1uF/50V & 47uF/50V @20MHz,
as close to pins as possible with nominal input and full load. Please see above.
100
0
Input Voltage (VAC)
80
115
100 230
20
40
60
80
90 264
Output Power (%)
RAC04/230
SAFE OPERATING AREA
Package Style and Pinning
36.7
36.0
17.1
4.0
0.6
21.0
7 65
4321
3.8 21.5 3.75x2
21.0
3.1
26.5
27.2
21.5 7.5
Primary
Isolation
Spacing
Secondary
Bottom View
Pin Connections
Pin # Single Out Dual Output Dual Output
1 No Pin No Pin No Pin
2 +VDC out +Vout +Vout
3 -VDC out Com Com
4 NC -Vout +12V
5 VAC in (L) VAC in (L) VAC in (L)
6 VAC in (N) VAC in (N) VAC in (N)
7* NC NC NC
NC = No Connection
xx.x = ±0.5mm
xx.xx = ±0.25mm
* Pin 7 is NC but need 4mm minimum clearence to ground for safety.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-22 www.recom-power.comREV: 0/2015

RAC04-3.3SC/230

Mfr. #:
Manufacturer:
RECOM Power
Description:
Switching Power Supplies 4W 3.3V 1200mA 80-264VIN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union