7522B0331-0

DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
Outer jacket color will be black (designated by a “-0" appended
to the part number, e.g. 7522B0331-0) unless otherwise
specied.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and sufxes may be added to
the part number, as necessary, to capture any additional
requirements imposed by the purchase order.
Users should evaluate the suitability of this product for their application. Specications are subject to change without notice. Tyco Electronics
Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication,
without notication to Buyer.
Page 1 of 1
Rayolin, Thermorad, Cheminax, Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
© 2012 Tyco Electronics Corporation, All rights reserved.
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
Raychem Wire & Cable
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS
REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE
ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
DIELECTRICS
Rayolin F
Colors - Tan/White
CONDUCTORS
AWG 22, 19 Strands of
AWG 34, Tin-Coated
Copper
.128
.154
.0315
SPECIFICATION CONTROL DRAWING
7522B0331
CHEMINAX
75 OHM, AWG 22, 19 STRANDS OF AWG 34, TWINAXIAL CABLE
Date 12-7-12
Revision A
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
.060
± .003
WRAP
Aluminum Polyester
JACKET
Thermorad S
CHARACTERISTIC IMPEDANCE 75 ± 7 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE 30.0 pF/ft. (nominal)
VELOCITY OF PROPAGATION 66% (nominal)
ADDITIONAL REQUIREMENTS
ELECTRICAL
CONDUCTOR RESISTANCE
(prior to cabling)
15.5 ohms/1000 ft. (nominal)
INSULATION RESISTANCE 10,000 megohms (minimum)
for 1000 ft.
JACKET FLAWS
SPARK TEST
IMPULSE TEST
1.0 kV (rms)
6.0 kV (peak)
VOLTAGE WITHSTAND (DIELECTRIC) 1000 volts (rms) (minimum)
ENVIRONMENTAL
FLAMMABILITY Method C
HEAT SHOCK 225°C
LOW TEMPERATURE-COLD BEND -55°C/4.25 inch mandrel
VOLTAGE WITHSTAND
(Post Environmental)
1000 volts (rms), 1 minute
PHYSICAL
INSULATION (DIELECTRIC)
(Prior to Cabling)
ELONGATION
TENSILE STRENGTH
200% (minimum)
1800 lbf/in
2
(minimum)
JACKET
ELONGATION
TENSILE STRENGTH
200% (minimum)
2000 lbf/in
2
(minimum)
JACKET THICKNESS .013 inch (nominal)
WRAP .002 inch thick (nominal)
25% minimum overlap
Aluminum side facing out
WEIGHT 14.4 lbs/1000 ft. (nominal)
DRAINWIRE
AWG 22, 19 Strands of
AWG 34, Tin-Coated
Copper

7522B0331-0

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Multi-Conductor Cables 7522B0331-0
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union