44A0312-24-0-US

TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft)
DIAMETER
(in.)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM MAXIMUM
44A0312-24-* 24 19 x 36 .023 .025 24.3 .057 ± .002 3.0
44A0312-22-* 22 19 x 34 .029 .032 15.1 .069 ± .003 4.3
44A0312-20-* 20 19 x 32 .037 .040 9.19 .078 ± .003 6.1
44A0312-18-* 18 19 x 30 .046 .050 5.79 .088 ± .003 8.7
44A0312-16-* 16 19 x 29 .052 .057 4.52 .097 ± .004 10.9
44A0312-14-* 14 19 x 27 .065 .072 2.88 .115 ± .004 16.2
44A0312-12-* 12 37 x 28 .084 .089 1.90 .131 ± .004 24.2
44A0312-10-* 10 37 x 26 .106 .112 1.19 .161 ± .005 36.5
44A0312-8-* 8 133 x 29 .158 .169 .658 .219 ± .006 65.0
44A0312-6-* 6 133 x 27 .198 .213 .418 .269 ± .007 103.
44A0312-4-* 4 133 x 25 .250 .268 .264 .325 ± .008 158.
44A0312-2-* 2 665 x 30 .320 .340 .170 .404 ± .012 252.
44A0312-0-* 0 1045 x 30 .405 .425 .108 .494 ± .016 380.
CONDUCTOR - SILVER-COATED COPPER
PRIMARY INSULATION - RADIATION-CROSSLINKED,
EXTRUDED POLYALKENE
JACKET - RADIATION-CROSSLINKED,
MODIFIED PVDF
Thickness:
AWG 24-4, .005 ± .001 in.
AWG 2-0, .010 ± .002 in.
SPECIFICATION CONTROL DRAWING
44A0312
WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED,
LIGHTWEIGHT, GENERAL PURPOSE, 2500 VOLT
7-21-08 F
This specication sheet forms a part of the latest issue of Raychem Specication 44.
Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED
TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 3
The TE logo, Tyco Electronics and Raychem are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2008 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING
Page 2 of 3 F
44A0312
SCD Number
Revision
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%)
WEIGHT
(lb) (± 3%)
IMMERSION
LIFE CYCLE AND
ACCELERATED AGING
COLD
BEND
WRAP
IMMERSION
LIFE CYCLE AND
ACCELERATED AGING
COLD
BEND
44A0312-24-* .500 1.00 .250 .625 3.00
44A0312-22-* .750 1.00 .250 2.00 3.00
44A0312-20-* .750 1.00 .250 2.50 4.00
44A0312-18-* 1.00 1.50 .375 2.50 4.00
44A0312-16-* 1.00 1.50 .375 2.50 5.00
44A0312-14-* 1.50 2.00 .500 2.50 5.00
44A0312-12-* 2.00 2.00 .500 3.00 5.00
44A0312-10-* 3.00 3.00 .750 3.00 5.00
44A0312-8-* 3.00 4.00 .750 6.00 6.00
44A0312-6-* 4.00 5.00 1.00 6.00 10.0
44A0312-4-* 5.00 6.00 1.25 6.00 10.0
44A0312-2-* 6.00 8.00 3.00 6.00 15.0
44A0312-0-* 8.00 10.0 4.00 7.00 15.0
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 2500 volts (rms) at sea level
ACCELERATED AGING: 300 ± 2°C for 6 hours
Identication legibility, 225 ± 2°C for 6 hours
BLOCKING: 150 ± 2°C for 24 hours
COLOR: White preferred
FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no aming of facial tissue
HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft. (minimum)
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown.
INSULATION ELONGATION AND TENSILE STRENGTH:
1.5 inch jaw separation, 2.0 inch/minute crosshead speed
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in² (minimum), AWG 24-12
2000 lbf/in² (minimum), AWG 10-0
INSULATION FLAWS:
Primary Insulation,
Spark Test, 5.0 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 8.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 13.0 kV (peak)
INSULATION RESISTANCE: 5000 megohms for 1000 ft. (minimum)
LIFE CYCLE: 200 ± 2°C for 168 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHRINKAGE: 300 ± 2°C, 0.125 in. (maximum) in 12 in., AWG 24-12
300 ± 2°C, 0.250 in. (maximum) in 12 in., AWG 10-0
SMOKE: 200 ± 2°C. No visible smoke.
SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings
THERMAL SHOCK RESISTANCE: 150 ± 2°C, 0.060 in. (maximum)
VOLTAGE WITHSTAND (Post Environmental): 5000 volts (rms), 60 Hz, 5 minutes
WICKING: 2.25 in. (maximum)
PART NUMBER: The "*" in the part numbers on pages 1 and 2 shall be replaced by color code
designators.
1/ Example: AWG 20, white: 44A0312-20-9
AWG 20, white with black stripe: 44A0312-20-90
1/ See footer section on page 1
SPECIFICATION CONTROL DRAWING
Page 3 of 3 F
44A0312
SCD Number
Revision
WIRE RATINGS AND ADDITIONAL REQUIREMENTS

44A0312-24-0-US

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Hook-up Wire 44A0312-24-0-US PRICE PER FOOT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet