R12P05D/P

ECONOLINE
DC/DC-Converter
with 3 year Warranty
RxxPxx
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
CSA/UL-60950-1 Certified*
* +15/-9 Version excluded
Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Std Capacitive
SIP 7 (VDC) (VDC) (mA) (%) Load
(1)
RxxP3.3S* 5, 9, 12, 15, 24 3.3 303 70 2200µF
RxxP05S* 5, 9, 12, 15, 24 5 200 70-75 1000µF
RxxP09S* 5, 9, 12, 15, 24 9 111 70-75 1000µF
RxxP12S* 5, 9, 12, 15, 24 12 84 70-75 470µF
RxxP15S* 5, 9, 12, 15, 24 15 66 75-80 470µF
RxxP3.3D* 5, 9, 12, 15, 24 ±3.3 ±151 70 ±1000µF
RxxP05D* 5, 9, 12, 15, 24 ±5 ±100 70-75 ±470µF
RxxP09D* 5, 9, 12, 15, 24 ±9 ±55 70-75 ±470µF
RxxP12D* 5, 9, 12, 15, 24 ±12 ±41 70-75 ±220µF
RxxP15D* 5, 9, 12, 15, 24 ±15 ±33 75-80 ±220µF
RxxP1509D* 12, 24 +15/-9 +33/-56 70-80 ±220µF
R05P1509D* 5 +15/-9 ±42 70-80 +68µF/-220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
R05P05S/P, R05P05D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P05S/X2, R05P05S/P/X2
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3, 5V output types 15% max.
(10% to 100% full load) other output types, RxxP1509D 10% max.
Output Ripple and Noise (20MHz BW) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
RxxP1509D 20kHz min. / 60kHz typ.
Efficiency at Full Load 65% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only
Isolation Voltages (tested for 1 second) 6400VDC
(rated for 1 minute**) 3200VAC / 60Hz
Isolation Capacitance 4pF min. / 10pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection, without derating) -40°C to +90°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
continued on next page
UL/CSA and EN Safety certified
EN-60601 for Medical Applications
Isolation 6.4kVDC
Optional Continuous Short Circuit Protected
/X2 Option for >9mm Input/Output Clearance
Suitable for IGBT Applications
Features
Unregulated
Converters
Description
Output Power (%)
100
60
20
40
100500-40
90
150
Operating Temperature °C
0
80
Safe Operating Area
95
1 Watt
SIP 7 Single
& Dual Output
Derating-Graph
(Ambient Temperature)
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA-60950 as well as
EN60950 and EN60601. This makes them ideal for medical and safety applications where
approved isolation is required.
Refer to Application Notes
E-358085
RoHS
2011/65EU
6/6
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please refer
to our Application Notes.
REV: 2/2015 E-69www.recom-power.com
Package Weight 4.3g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 2974 x 10
3
hours
(+85°C) using MIL-HDBK 217F 728 x 10
3
hours
Certifications
UL/cUL General Safety Report: E358085-A8 UL 60950-1 2nd Ed.
EN General Safety Report: SPCLVD1305069 EN60950-1:2006 + A12: 2011
EN Medical Safety Report: SPCMDD1205098-4 IEC/EN60601-1:2006, 3rd Edition
RxxPxx
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P09S
R12P05S
R12P09S
R05P05S
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R05P05S
0.000
5.000
10.000
15.000
20.000
25.000
R12P05S
R05P09S
R12P05D
ECONOLINE
DC/DC-Converter
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P09D
R12P09D
R12P05D
R05P05D
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R05P05D
0.000
5.000
10.000
15.000
20.000
25.000
R12P05D
R05P09D
R12P09D
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up))
Tolerance Envelope
+10%
+5%
V Nom.
+5%
 1.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
RxxPxxS_D
Series
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RxxP05S
RxxP05D
RxxP09S
RxxP09D
REV: 2/2015 www.recom-power.comE-70
RxxPxx
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R24P15S
R24P12S
R12P12S
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R12P12S
0.000
5.000
10.000
15.000
20.000
25.000
R24P15S
R24P12S
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R12P12D
0.000
5.000
10.000
15.000
20.000
25.000
R24P15D
R24P12D
ECONOLINE
DC/DC-Converter
ECONOLINE
DC/DC-Converter
Typical Characteristics
EMC Filter Suggestions for EN55022 Class A and B
RxxPxxS_D
Series
RxxP12D, RxxP15D
RxxP12S, RxxP15S
REV: 2/2015 E-71www.recom-power.com
++
Output
Input
L1
C3
C2C1
C1 L1 C2 C3
EN55022 Class A 10μF NA NA NA
EN55022 Class B 10μF
470μH
WE 7447471471
10μF
2n2F 8kV
Vishay HGZ222MBP

R12P05D/P

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 1W DC/DC 5.2kV UNREG 12Vin +/-5Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union