ECONOLINE
DC/DC-Converter
with 3 year Warranty
RxxPxx
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
CSA/UL-60950-1 Certified*
* +15/-9 Version excluded
Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Std Capacitive
SIP 7 (VDC) (VDC) (mA) (%) Load
(1)
RxxP3.3S* 5, 9, 12, 15, 24 3.3 303 70 2200µF
RxxP05S* 5, 9, 12, 15, 24 5 200 70-75 1000µF
RxxP09S* 5, 9, 12, 15, 24 9 111 70-75 1000µF
RxxP12S* 5, 9, 12, 15, 24 12 84 70-75 470µF
RxxP15S* 5, 9, 12, 15, 24 15 66 75-80 470µF
RxxP3.3D* 5, 9, 12, 15, 24 ±3.3 ±151 70 ±1000µF
RxxP05D* 5, 9, 12, 15, 24 ±5 ±100 70-75 ±470µF
RxxP09D* 5, 9, 12, 15, 24 ±9 ±55 70-75 ±470µF
RxxP12D* 5, 9, 12, 15, 24 ±12 ±41 70-75 ±220µF
RxxP15D* 5, 9, 12, 15, 24 ±15 ±33 75-80 ±220µF
RxxP1509D* 12, 24 +15/-9 +33/-56 70-80 ±220µF
R05P1509D* 5 +15/-9 ±42 70-80 +68µF/-220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
R05P05S/P, R05P05D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P05S/X2, R05P05S/P/X2
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3, 5V output types 15% max.
(10% to 100% full load) other output types, RxxP1509D 10% max.
Output Ripple and Noise (20MHz BW) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
RxxP1509D 20kHz min. / 60kHz typ.
Efficiency at Full Load 65% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only
Isolation Voltages (tested for 1 second) 6400VDC
(rated for 1 minute**) 3200VAC / 60Hz
Isolation Capacitance 4pF min. / 10pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection, without derating) -40°C to +90°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
continued on next page
●
UL/CSA and EN Safety certified
●
EN-60601 for Medical Applications
● Isolation 6.4kVDC
●
Optional Continuous Short Circuit Protected
●
/X2 Option for >9mm Input/Output Clearance
● Suitable for IGBT Applications
Features
Unregulated
Converters
Description