ELG-75 series
SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
500ms, 100ms/115VAC, 230VAC
10ms/ 230VAC 10ms/ 115VAC(at full load)
47 ~ 63Hz
0.7A / 115VAC 0.45A / 230VAC 0.38A/277VAC
<0.75mA / 277VAC
Compliance to
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
180 63**35.5mm (L*W*H)
ENVIRONMENT
EMC EMISSION
SAFETY &
EMC
PROTECTION
Shut down output voltage, re-power on to recover
Shut down output voltage, re-power on to recover
SHORT CIRCUIT
0.8Kg;16pcs/13.4Kg/0.67CUFT
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ELG-75-24
200mVp-p
1.57 ~ 3.15A
88%
28 ~ 34V
12 ~ 24V
24V
75.6W
14 ~ 18V
85%
6 ~ 12V
ELG-75-12
150mVp-p
2.5 ~ 5A
12V
60W
ELG-75-42
250mVp-p
0.9 ~ 1.8A
90%
47 ~ 54V
21 ~ 42V
42V
75.6W
TOTAL HARMONIC DISTORTION
DC VOLTAGE
RATED CURRENT
RATED POWER
Note.5
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
RIPPLE & NOISE (max.)
Note.3
VOLTAGE TOLERANCE
Note.4
CONSTANT CURRENT REGION
Note.2
OVER CURRENT
SAFETY STANDARDS
ELG-75-36
250mVp-p
1.05 ~ 2.1A
89%
41 ~ 48V
18 ~ 36V
36V
75.6W
ELG-75-48
250mVp-p
0.8 ~ 1.6A
90%
54 ~ 62V
24 ~ 48V
48V
76.8W
±3.0%
±0.5%
±2.0%
21.6 ~ 26.4V
32.4 ~ 39.6V
37.8 ~ 46.2V
10.8 ~ 13.2V
43.2 ~ 52.8V
3.15A
5A
1.8A
2.1A
1.6A
±3.0%
±0.5%
±1.0%
±2.5%
±0.5%
±1.0%
±2.5%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
Adjustable for A/AB-Type only (via built-in potentiometer)
Adjustable for A/AB-Type only (via built-in potentiometer)
COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VACμ;Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
MAX. CASE TEMP.
Tcase=+85℃
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level ( )surge immunity Line-Earth 6KV, Line-Line 4KV ;
EAC TP TC 020
(Please refer to "STATIC CHARACTERISTIC" section)
100 ~ 305VAC 142 ~ 431VDC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70 or less.℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
10.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
48~75W Constant Voltage + Constant Current LED Driver
95 ~ 108%
Hiccup mode, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
No load power consumption <0.5W for Blank / A / Dx / D2-Type
NO LOAD / STANDBY
POWER CONSUMPTION
Standby power consumption <0.5W for B / AB / DA-Type
Tcase=-40 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
UL8750 independent, EN62384;(type”HL”), CSA C22.2 No. 250.13-12; IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13
;IP65 or IP67; approvedEAC TP TC 004;BIS IS15885(for 12B/24B/36A/42A/48A only) GB19510.1, GB19510.14
EN55015,EN61000-3-2 Class C (@load 50%) ; EN61000-3-3;≧ GB17743, GB17625.1;EAC TP TC 020
1172K hrs min. Telcordia SR-332 (Bellcore) 331Khrs min. MIL-HDBK-217F (25 )℃
60W
48W
60W
60W
60W
200VAC ~ 305VAC
100VAC ~ 180VAC
DALI STANDARDS
Compliance to IEC62386-101, 102, 207 for DA-Type only
File Name:ELG-75-SPEC 2018-05-29