AQ8
–4–
ASCTB213E 201410-T
• 3 A type
Notes: *1. Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
REFERENCE DATA
Part No.
Item
AQ3A1-C1-
T5VDC
AQ3A1-C2-
T5VDC
AQ3A1-C1-
T12VDC
AQ3A1-C2-
T12VDC
AQ3A1-C1-
T24VDC
AQ3A1-C2-
T24VDC
AQ3A2-C1-
T5VDC
AQ3A2-C2-
T5VDC
AQ3A2-C1-
T12VDC
AQ3A2-C2-
T12VDC
AQ3A2-C1-
T24VDC
AQ3A2-C2-
T24VDC
Remarks
Input
side
Control voltage
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
*
1
Input impedance Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 3 A*
2
At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage
400 V 600 V
Non-repetitive
surge current
80 A*
3
In one cycle at 60 Hz
Max. “OFF-state”
leakage current
2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop
1.6 V at max. carrying current
Min. load current 25 mA*
4
50 mA*
4
OFF state dV/dt 50 V/μs
At ambient temperature of
80°C
Type
Item
Zero-cross type Random type Remarks
Operate time, max. 1/2 cycle of voltage sine wave + 1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min. 10
9
Ω between input and output at 500 V DC
Breakdown voltage 3,000 V AC between input and output For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 3 mm 1 hour for X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 3 mm 10 min. for X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s
2
{100 G} 5 times each for X, Y, Z axis
Functional Min. 980 m/s
2
{100 G} 4 times each for X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn ON and Turn OFF) Random turn ON, zero-cross turn OFF
1. Characteristics of load current vs. ambient
temperature
Use load current within range specified in the figure
below.
2 A type
3 A type
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
3.0
2.-(1) Characteristics of non-repetitive surge
current vs. carrying time
(2 A type)
2.-(2) Characteristics of non-repetitive surge
current vs. carrying time
(3 A type)
5 10 50 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100
5 10 50 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100