AQ2A1-C2-ZT12VDC

AQ8
–4–
ASCTB213E 201410-T
• 3 A type
Notes: *1. Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
REFERENCE DATA
Part No.
Item
AQ3A1-C1-
T5VDC
AQ3A1-C2-
T5VDC
AQ3A1-C1-
T12VDC
AQ3A1-C2-
T12VDC
AQ3A1-C1-
T24VDC
AQ3A1-C2-
T24VDC
AQ3A2-C1-
T5VDC
AQ3A2-C2-
T5VDC
AQ3A2-C1-
T12VDC
AQ3A2-C2-
T12VDC
AQ3A2-C1-
T24VDC
AQ3A2-C2-
T24VDC
Remarks
Input
side
Control voltage
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
*
1
Input impedance Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 3 A*
2
At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage
400 V 600 V
Non-repetitive
surge current
80 A*
3
In one cycle at 60 Hz
Max. “OFF-state”
leakage current
2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop
1.6 V at max. carrying current
Min. load current 25 mA*
4
50 mA*
4
OFF state dV/dt 50 V/μs
At ambient temperature of
80°C
Type
Item
Zero-cross type Random type Remarks
Operate time, max. 1/2 cycle of voltage sine wave + 1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min. 10
9
Ω between input and output at 500 V DC
Breakdown voltage 3,000 V AC between input and output For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 3 mm 1 hour for X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 3 mm 10 min. for X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s
2
{100 G} 5 times each for X, Y, Z axis
Functional Min. 980 m/s
2
{100 G} 4 times each for X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn ON and Turn OFF) Random turn ON, zero-cross turn OFF
1. Characteristics of load current vs. ambient
temperature
Use load current within range specified in the figure
below.
2 A type
3 A type
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
3.0
2.-(1) Characteristics of non-repetitive surge
current vs. carrying time
(2 A type)
2.-(2) Characteristics of non-repetitive surge
current vs. carrying time
(3 A type)
5 10 50 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100
5 10 50 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100
AQ8
–5–
ASCTB213E 201410-T
DIMENSIONS (mm inch)
3. Characteristics of input current vs. input
voltage
—zero-cross type
---Random type
(5 V type)
(12 V type)
(24 V type)
30
25
20
15
10
5
0
Input voltage, V
Input current, mA
0102030
4.-(1) Characteristics of load current vs.
ambient temperature for adjacent mounting
(2 A type)
Conditions: Natural cooling
4.-(2) Characteristics of load current vs.
ambient temperature for adjacent mounting
(3 A type)
Conditions: Natural cooling
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
=20.32 mm
=9.0 mm
=12.7 mm
=Adjacent mounting pitch
.800 inch
.354 inch
.500 inch
2.0
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
=20.32 mm
=9.0 mm
=12.7 mm
=Adjacent mounting pitch
3.0
1.0
.800 inch
.354 inch
.500 inch
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
(Common for zero-cross and random types)
1. Input terminals distance 5.08 mm .200 inch
1) 2 A type
External dimensions
General tolerance: ±0.5 ±.020
5.08
5.08
12.7
10.16
45 max.
24 max.
3421
9 max.
8 min.
4-0.8 dia.
2.5
INPUT LOAD
3421
+
.200
.200
.500
.400
1.772
.945
.315
.098
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
Terminal
Copper foil
43 2 1
2.54×5
4-1.2 dia.
27.94
1.100
.100×5
2.54×2
.100×2
2.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
2) 3 A type
External dimensions
General tolerance: ±0.5 ±.020
5.08
5.08
12.7
10.16
9 max.
43 max.
32 max.
8 min.
3421
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.200
.500
.400
1.693
1.259
.315
.098
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
Terminal
Copper foil
43 2 1
2.54×5
4-1.2 dia.
27.94
1.100
.100×5
2.54×2
.100×2
2.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
AQ8
–6–
ASCTB213E 201410-T
2. Input terminals distance 7.62 mm .300 inch
1) 2A type
External dimensions
General tolerance: ±0.5 ±.020
7.62
5.08
12.7
10.16
9 max.
45 max.
24 max.
8 min.
34
2
1
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.500
.400
1.772
.945
.315
.098
.300
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
43 2 1
Terminal
Copper foil
2.54×5
4-1.2 dia.
30.48
1.200
.100×5
2.54×3
.100×3
2.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
2) 3A type
External dimensions
General tolerance: ±0.5 ±.020
5.08
12.7
10.16
9 max.
43 max.
32 max.
8 min.
7.62
3421
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.500
.400
1.693
1.259
.315
.098
.300
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
43 2 1
Terminal
Copper foil
2.54×5
4-1.2 dia.
30.48
1.200
.100×5
2.54×3
.100×3
2.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data

AQ2A1-C2-ZT12VDC

Mfr. #:
Manufacturer:
Panasonic
Description:
Solid State Relays - PCB Mount 2A 12VDC Zero Cross
Lifecycle: