Document Number: 38-05328 Rev. *M Page 4 of 18
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. User guidelines are not tested.
Storage temperature ................................ –65 °C to +150 °C
Ambient temperature with
power applied .......................................... –55 °C to +125 °C
Supply voltage to ground potential ..... –0.2 V to V
CC
+ 0.3 V
DC voltage applied to outputs
in High-Z state
[5, 6]
............................. –0.2 V to V
CC
+ 0.3 V
DC input voltage
[5, 6]
..........................–0.2 V to V
CC
+ 0.3 V
Output current into outputs (LOW) .............................20 mA
Static discharge voltage
(per MIL-STD-883, Method 3015) ......................... > 2001 V
Latch-up current ....................................................> 200 mA
Operating Range
Device Range
Ambient
Temperature
V
CC
[7]
CY62167DV30LL Industrial –40 °C to +85 °C 2.20 V to
3.60 V
Electrical Characteristics
Over the Operating Range
Parameter Description Test Conditions
CY62167DV30-55 CY62167DV30-70
Unit
Min Typ
[8]
Max Min Typ
[8]
Max
V
OH
Output HIGH voltage I
OH
= –0.1 mA V
CC
= 2.20 V 2.0 – – 2.0 – – V
I
OH
= –1.0 mA V
CC
= 2.70 V 2.4 2.4
V
OL
Output LOW voltage I
OL
= 0.1 mA V
CC
= 2.20 V – – 0.4 – 0.4 V
I
OL
= 2.1 mA V
CC
= 2.70 V
V
IH
Input HIGH voltage V
CC
= 2.2 V to 2.7 V 1.8 – V
CC
+ 0.3 1.8 – V
CC
+ 0.3 V
V
CC
= 2.7 V to 3.6 V 2.2 2.2
V
IL
Input LOW voltage V
CC
= 2.2 V to 2.7 V –0.3 – 0.6 –0.3 – 0.6 V
V
CC
= 2.7 V to 3.6 V 0.8 0.8
I
IX
Input leakage current GND V
I
V
CC
–1 – +1 –1 – +1 A
I
OZ
Output leakage current GND V
O
V
CC
, output
disabled
–1 – +1 –1 – +1 A
I
CC
V
CC
operating supply
current
V
CC
= V
CC(max)
I
OUT
= 0 mA
CMOS levels
f = f
Max
= 1/t
RC
– 15 30 – 12 25 mA
f = 1 MHz 2 4 2 4
I
SB1
Automatic power-down
current – CMOS inputs
CE
1
V
CC
0.2 V or CE
2
0.2 V,
V
IN
V
CC
– 0.2 V, V
IN
0.2 V,
f = f
Max
(address and data only),
f = 0 (OE, WE), V
CC
= 3.60 V
– 2.5 22 – 2.5 22 A
I
SB2
Automatic power-down
current – CMOS Inputs
CE
1
V
CC
– 0.2 V or
CE
2
0.2 V
V
IN
V
CC
– 0.2 V or V
IN
0.2V,
f = 0, V
CC
= 3.60 V
– 2.5 22 – 2.5 22 A
Notes
5. V
IL(min.)
= –2.0 V for pulse durations less than 20 ns.
6. V
IH(max)
= V
CC
+ 0.75 V for pulse durations less than 20 ns.
7. Full Device AC operation requires linear V
CC
ramp from 0 to V
CC(min.)
and V
CC
must be stable at V
CC(min)
for 500s.
8. Typical values are included for reference only and are not guaranteed or tested. Typical values are measured at V
CC
= V
CC(typ)
, T
A
= 25 °C.