7
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
-40 -20 0 20 40 60 80 100
I
O
- OUTPUT CURRENT - A
T
A
-TEMPERATURE -
°C
I
F
= 5mA
θ
CA
= 76
°C
SAFE
OPERATING
AREA
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
70 90 110 130 150
T
C
- CASE TEMPERATURE - °C
SAFE
OPERATING
AREA
P
O
- OUPUT POWER DISSIPATION - W
Figure 1. Maximum Average Output Current Rat-
ing vs Ambient Temperature
Figure 2. Output Power Derating vs Case Tem-
perature
0.9
0.95
1
1.05
1.1
-50 -25 0 25 50 75 100
T
A
- TEMPERATURE -
°C
NORMALIZED OUTPUT WITHSTAND VOLTAGE
I
O
= 250 μA
V
F
= 0.8V
Figure 3. Normalized Typical Output Withstand
Voltage vs. Temperature
Switching Speci cations (AC)
Over recommended operating T
A
= -40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Turn On Time T
ON
0.25 0.5 ms I
F
=5mA, I
O
=200mA,
T
A
=25C
10, 14
1.0 ms I
F
=5mA, I
O
=200mA 11
Turn O Time T
OFF
0.02 0.2 ms I
F
=5mA, I
O
=200mA,
T
A
=25C
12, 14
0.5 ms I
F
=5mA, I
O
=200mA 13
Output Transient Rejec-
tion
dV
O
/dt 1 7
kV/s V
O
=250V, T
A
=25C
15
Input-Output
Transient Rejection
dV
I-O
/dt 1
10 kV/s V
I-O
=1000V,
T
A
=25C
16
Notes:
1. For derating, refer to Figure 1 and 2.
2. Threshold to switch device is I
F
0.5mA, however, for quali ed device performance over temperature range, it is recommended to operate at
I
F
=5mA. Refer to application information in next section of this datasheet.
3. Device is considered as a two terminal device: pins 1, 2, 3 and 4 shorted together and pins 5, 6, 7 and 8 shorted together.
4. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety speci cation, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
5. The PCB design and environmental conditions are taken into consideration when measuring the I
O(OFF)
performance.
6. During the pulsed R
(ON)
measurement ( I
O
duration 30ms), ambient (T
A
) and case temperature (T
C
) are equal.