Page
6.Environmental Test
Item Specifications
6-1. Exposure to high temp.
at +125℃ for 240 hours
6-2. Exposure to low temp.
at -40℃ for 240 hours
6-3. Thermal shock test
-40℃ , 0.5Hr
+125℃ , 0.5Hr
6-4. Exposure to humidity
60℃ ,at 90〜95%RH for 240 hours.
6-5. Vibration
10〜55〜10Hz, total amplitude 1.52mm one minute sweep
/1 cycles X,Y,Z axis for two hours respectively.
6-6. Impact Apply 100G for three times for X,Y,Z axis respectively.
6-7. Dropping Dropped two times freely on a lauan plate from the height
of 75cm.
6-8. Solderability
245℃ for 5 seconds .Flux and a plate in 1.6mm thick are used
for this test.
6-9. Resistance to soldering heat
350℃ for 3 seconds .Flux and a plate of 1.6mm thick are used
for this test.
6-10. Continuous operation
Apply 50% duty square wave 20V
o-p
2.0KHz for 240 hours.
Page 4 of 7
Ver.No.:XB5-1102-749E(00)
Submit to 25 cycles of the following sequence conditions in air :