UWR-5/1600-D5A-C

Effi ciency vs. Output Current and Input Voltage
Output Voltage vs. Input Voltage and Output Current Output Voltage vs. Output Current and Input Voltage
LINE REGULATION
LOAD REGULATION
Typical Performance Curves (TA = +25°C)
The performance curves below were derived from actual test data for a single model number (UWR-5/1800-D48A).
Since all devices in the 6-10W UWR A-Series have the same circuit topology, the performance curves are representative of all devices.
84
81
78
75
72
69
66
63
60
Efficiency (%)
Out
p
ut Current
(
Am
p
s
)
V
IN
= 72V
V
IN
= 48V
V
IN
= 18V
0.3 0.6 0.9 1.2 1.5 1.80.18
EFFICIENCY
0.3 0.6 0.9 1.2 1.5 1.8
Output Current (Amps)
V
IN
= 72V
V
IN
= 48V
V
IN
= 18V
5.016
5.014
5.012
5.010
5.008
5.006
5.004
5.002
5.000
V
OUT
(Volts)
0.18
5.016
5.014
5.012
5.010
5.008
5.006
5.004
5.002
5.000
V
OUT
(Volts)
18 24 30 36 42 48 54 60 66 72
V
IN
(
Volts
)
I
OUT
= 1.8A
I
OUT
= 0.9A
I
OUT
= 0.18A
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC-DC Converters
MDC_UWR6-10W Series.E01 Page 4 of 6
www.murata-ps.com/support
If you’re designing with EMC in mind, please note that all of Murata Power
Solutions' A-Series UWR 6-10 Watt DC/DC Converters have been character-
ized for radiated and conducted emissions in our new EMI/EMC labora-
tory. Testing is conducted in an EMCO 5305 GTEM test cell utilizing EMCO
automated EMC test software. Radiated emissions are tested to the limits
of FCC Part 15, Class B and CISPR 22 (EN 55022), Class B. Radiated emis-
sions plots to FCC and CISPR 22 for model UWR-12/665-D5A appear below.
80
70
60
50
40
30
20
10
0
–10
–20
Frequency (MHz)
100
1000
Radiated Emissions
FCC Class B Limit
UWR-12/665-D5A Radiated Emissions
FCC Part 15 Class B, 3 Meters
Converter Output = 12Vdc @ 620mA
Radiated Emissions (dBµV/M)
UWR-12/665-D5A Radiated Emissions
EN 55022 Class B, 10 Meters
Converter Output = 12Vdc @ 620mA
80
70
60
50
40
30
20
10
0
–10
–20
Frequency (MHz)
100
1000
Radiated Emissions
EN 55022 Class B Limit
Radiated Emissions (dBµV/M)
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For Murata Power
Solutions A-Series UWR 6-10 Watt DC/DC Converters, you should use slow-
blow type fuses with values no greater than the following:
V
IN Range Fuse Value
D5A 3A
D12A and D24E 2A
D48A and D48E 1A
Murata Power Solutions' world-class design, development and manu-
facturing team stands ready to work with you to deliver the exact power
converter you need for your demanding, large volume, OEM applications.
And ... we’ll do it on time and within budget!
Our experienced applications and design staffs; quick-turn prototype
capability; highly automated, SMT assembly facilities; and in-line SPC
quality-control techniques combine to give us the unique ability to design
and deliver any quantity of power converters to the highest standards of
quality and reliability.
We have compiled a large library of DC/DC designs that are currently used
in a variety of telecom, medical, computer, railway, aerospace and indus-
trial applications. We may already have the converter you need.
Contact us. Our goal is to provide you the highest-quality, most cost-
effective power converters available.
CUSTOM CAPABILITIES
EMI RADIATED EMISSIONS
Quality and Reliability
The A-Series are the fi rst DC/DC Converters to emerge from Murata Power
Solutions' new, company-wide approach to designing and manufacturing
the most reliable power converters available. The fi ve-pronged program
draws our Quality Assurance function into all aspects of new-product
design, development, characterization, qualifi cation and manufacturing.
Design for Reliability
Design for Reliability is woven throughout our multi-phased, new-product-
development process. Design-for-reliability practices are fully documented
and begin early in the new-product development cycle with the following
goals:
1. To work from an approved components/vendors list ensuring the use of
reliable components and the rigorous qualifi cation of new components.
2. To design with safety margins by adhering to a strict set of derating
guidelines and performing theoretical worst-case analyses.
3. To locate potential design weaknesses early in the product-development
cycle by using extensive HALT (Highly Accelerated Life Testing).
4. To prove that early design improvements are effective by employing a
thorough FRACA (Failure Reporting Analysis and Corrective Action) System.
Soldering Guidelines
Murata Power Solutions recommends the specifi cations below when installing these
converters. These specifi cations vary depending on the solder type. Exceeding these
specifi cations may cause damage to the product. Be cautious when there is high atmo-
spheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your
production environment may differ; therefore please thoroughly review these guidelines
with your process engineers.
Wave Solder Operations for through-hole mounted prod-
ucts (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature 115° C.
Maximum Pot Temperature 270° C.
Maximum Solder Dwell Time 7 seconds
For Sn/Pb based solders:
Maximum Preheat Temperature 105° C.
Maximum Pot Temperature 250° C.
Maximum Solder Dwell Time 6 seconds
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC-DC Converters
MDC_UWR6-10W Series.E01 Page 5 of 6
www.murata-ps.com/support
HALT Testing
The goal of the accelerated-stress techniques used by Murata Power
Solutions is to force device maturity, in a short period of time, by exposing
devices to excessive levels of "every stimulus of potential value." We use
HALT (Highly Accelerated Life Testing) repeatedly during the design and
early manufacturing phases to detect potential electrical and mechanical
design weaknesses that could result in possible future fi eld failures.
During HALT, prototype and pre-production DC/DC converters are sub-
jected to progressively higher stress levels induced by thermal cycling,
rate of temperature change, vibration, power cycling, product-specifi c
stresses (such as dc voltage variation) and combined environments. The
stresses are not meant to simulate fi eld environments but to expose any
weaknesses in a product’s electro/mechanical design and/or assembly
processes. The goal of HALT is to make products fail so that device weak-
nesses can be analyzed and strengthened as appropriate. Applied stresses
are continually stepped up until products eventually fail. After corrective
actions and/or design changes, stresses are stepped up again and the cycle
is repeated until the "fundamental limit of the technology" is determined.
Murata Power Solutions has invested in a Qualmark OVS-1 HALT tester
capable of applying voltage and temperature extremes as well as 6-axis,
linear and rotational, random vibration. A typical HALT profi le (shown above)
consists of thermal cycling (–55 to +125°C, 30°C/minute) and simultane-
ous, gradually increasing, random longitudinal and rotational vibration up
to 20G’s with load cycling and applied-voltage extremes added as desired.
Many devices in Murata Power Solutions' new A-Series could not be made
to fail prior to reaching either the limits of the HALT chamber or some previ-
ously known physical limit of the device.
We also use the HALT chamber and its ability to rapidly cool devices to
verify their "cold-start" capabilities.
Qualifi cation
For each new product, electrical performance is verifi ed via a comprehen-
sive characterization process and long-term reliability is confi rmed via a
rigorous qualifi cation procedure. The qual procedure includes such strenu-
ous tests as thermal shock and 500 hour life. Qual testing is summarized
below.
In-Line Process Controls and Screening
A combination of statistical sampling and 100% inspection techniques
keeps our assembly line under constant control. Parameters such as
solder-paste thickness, component placement, cleanliness, etc. are statisti-
cally sampled, charted and fi ne tuned as necessary. Visual inspections are
performed by trained operators after pick-and-place, soldering and cleaning
operations. Units are 100% electrically tested prior to potting. All devices
are temperature cycled, burned-in, hi-pot tested and fi nal-electrical tested
prior to external visual examination, packing and shipping.
Rapid Response to Problems
Murata Power Solutions employs an outstanding corrective-action system
to immediately address any detected shortcomings in either products or
processes. Whenever our assembly, quality or engineering personnel spot
a product/process problem, or if a product is returned with a potential
defect, we immediately perform a detailed failure analysis and, if necessary,
undertake corrective actions. Over time, this system has helped refi ne our
assembly operation to yield one of the lowest product defect rates in the
industry.
Typical HALT Profi le
Qualifi cation Test Method/Comments
HALT Murata Power Solutions in-house procedure
High Temperature Storage Max. rated temp., 1,000 hours
Thermal Shock 10 cycles, –55 to +125°C
Temperature/Humidity +85°C, 85% humidity, 48 hours
Lead Integrity Murata Power Solutions in-house procedure
Life Test +70°C, 500 hours*
Marking Permanency Murata Power Solutions in-house procedure
End Point Electrical Tests Per product specifi cation
Qualifi cation Testing
* Interim electrical test at 200 hours.
10 20 30 40 50 60 70 80 90
40
20
0
Random Vibration
(
G's
)
Temperature (°C)
Test Time (minutes)
100
80
60
40
20
0
–20
–40
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC-DC Converters
MDC_UWR6-10W Series.E01 Page 6 of 6
www.murata-ps.com/support
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without
notice. © 2015 Murata Power Solutions, Inc.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/

UWR-5/1600-D5A-C

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters 8W 5V to 5V 1600mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: