TS-3000-212B

SPECIFICATION
TS-3000-112 TS-3000-124 TS-3000-148 TS-3000-212 TS-3000-224 TS-3000-248
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1Hz 50/60Hz selectable by setting button S.W±
150A
24V
21 ~ 30VDC
90%
75A
48V
42 ~ 60VDC
91%
150A
24V
21 ~ 30VDC
91%
75A
48V
42 ~ 60VDC
92%
MODEL
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.7
OUTPUT
FREQUENCY
AC REGULATION (Typ.)
FRONT PANEL INDICATOR
SAVING MODE (Typ.)
NO LOAD DISSIPATION (Typ.)
BAT. VOLTAGE
VOLTAGE RANGE (Typ.)
Note.3,6
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.) Note.4
INPUT
INPUT
PROTECTION
BATTERY
OUTPUT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
Note.6
BAT. LOW SHUTDOWN Note.6
OVER TEMPERATURE
OUTPUT SHORT
REVERSE POLARITY
GFCI PROCTECTION
100 / 110 / 115 / 120VAC selectable by setting button S.W
3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
True sine wave (THD<3%)
60 0.1Hz 50/60Hz selectable by setting button S.W±
300A
12V
10.5 ~ 15VDC
89%
40A*12 40A*6 20A*6
20A*640A*6
11.3V
22.5V 45V45V22.5V
10.5V 21V 42V42V21V
±
3%
Default disabled. Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
10W @ standby saving mode
12V
1mA
10.5 ~ 15VDC
88%
300A
40A*12
11.3V
10.5V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A, EAC TP TC 020
Compliance to EAC TP TC 020
WORKING TEMP. Note.2
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
0 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
Compliance to EN61000-4-2,3,4,5,6,8,11, EAC TP TC 020
Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
True sine wave output (THD<3%)
High surge power up to 6000W
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software and connection cable
(MW order No.: DS-TN-1500)
3 years warranty
RATED POWER (Typ.) 3000W
BATTERY TYPES
OVER LOAD (Typ.)
CIRCUIT BREAKER
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
AC output receptacle:15A
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25 / 70% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
3000W True Sine Wave DC-AC Inverter
TS-3000 series
OTHERS
PACKING
12.9Kg; 1pcs/14Kg/1.49CUFT
DIMENSION
CONTROL WIRING
466.8*283.5*100mm (L*W*H)
RJ11 -RS232 (Option)
File Name:TS-3000-SPEC 2018-01-15
NOTE
1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.Input derating capacity referenced by curve 2.
4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
5.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
6.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.→± →± →±
7.THD is tested by 3000W, linear load at 13,26,52V input voltage.
8.Please do not turn on the inverter before start the engine if inverter connect to vehicle’s battery directly.
9.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
AC VOLTAGE
Factory setting set at 110VAC Factory setting set at 230VAC
PROTECTION
ENVIRONMENT
LVD
None
EN60950-1
EAC TP TC 004
E
13
90 5℃± 85 5℃± 85 5℃± 80 5℃± 75 5℃± 75 5℃±
OFF MODE CURRENT DRAW (Typ.)
Open & sealed lead acid battery
EMC IMMUNITY
EMC EMISSION
U 458 (L only for Type G ), EAC TP TC 004
AC Output Receptacle (optional)
Unit:mm
Mechanical Specification
Derating Curve
12:12VDC
24:24VDCBat. Voltage:
48:48VDC
1:110VAC
2:230VAC
Output:
O/P Wattage:3000W
3000 112 A
CURVE 1
AMBIENT TEMPERATURE ( )
010203040506070
20
40
60
80
100
LOAD (%)
CURVE 2
BATTERY INPUT VOLTAGE (V)
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
20
40
60
80
100
(HORIZONTAL)
LOAD (%)
122.44
161.84
100
31.6
Reverse Polarity
Will Damage The
Unit.
NEG
POS
direction
Air flow
direction
Air flow
273
34
12
283.5
286.2
90.3
466.8
46
7
7.5
AC OUTPUT
FG
NC
L
NC
N
On
Bat Low
Saving
Setting
Remote
port
INVERTER
LOAD
100
BATTERY
0
100
0
C
i
r
c
u
i
t
B
r
e
a
k
e
r
P
r
e
s
s
t
o
R
e
s
e
t
AC OUTPUT
ON
OFF
31.29
13
AC OUTPUT
On
Bat Low
Saving
Setting
Remote
port
INVERTER
LOAD
100
BATTERY
0
100
0
C
i
r
c
u
i
t
B
r
e
a
k
e
r
P
r
e
s
s
t
o
R
e
s
e
t
ON
OFF
31.29
13
Chassis
Ground
Cat.No.(1GG1HS-212)
Wire Range(10-4AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
Chassis
Ground
Cat.No.(1GG1HS-212)
Wire Range(10-4AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
AC Receptacle
AC Receptacle
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
G :TYPE G TERMINAL
TYPE-A
Receptacle type
Country
Certificate
TYPE-B
TYPE-C
TYPE-D
TYPE-E TYPE-F
USA
EUROPE
AUSTRALIA
U.K
JAPAN GFCI
E
13
EE
13 13
TYPE-G
(Terminal only)
-----
(Except for 48V input)
3000W True Sine Wave DC-AC Inverter
TS-3000 series
File Name:TS-3000-SPEC 2018-01-15
Type-A
Note: When the load current is >15A, must
use output terminal connection which
can be found inside the AC output panel
of the inverter.
Type-B
TS:True sine wave inverter
TS

TS-3000-212B

Mfr. #:
Manufacturer:
Description:
Power Inverters 3000W 230VACout 12Vin 300A Euro
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union