Layout Part Description
Stratix
Industrial
Ethernet Switches
Power
Input
Panduit
Networked UPS Uplinks
Downlink Port
Connectivity
Provided
Maximum
Downlink
Port Count
Z23N-SBAAD5
24" x 36" Network Zone System with Stratix 8000 1783-MS10T switch with 2 1Gb MM fi ber optic uplinks, with redundant
power supplies and no battery maintenance-free UPS.
Stratix 8000* Modular Managed
Switch 1783-MS10T
100-250 V ac No Battery,
Maintenance-free,
with remote
management
UPS, estimated
holdtime = 7 minutes
fully expanded
Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
8 RJ45 Ethernet 48 RJ45 Ethernet
‡‡
Z23N-SBABD5
24" x 36" Network Zone System with Stratix 8000 1783-MS10T switch with 2 1Gb MM fi ber optic uplinks and 1783-MX08T
expansion module, with redundant power supplies and no battery maintenance-free UPS.
16 RJ45 Ethernet
Z23N-SBABA5
24" x 36" Network Zone System with Stratix 8000 1783-MS10T switch with 2 1Gb copper uplinks and 1783-MX08T
expansion module, with redundant power supplies and no battery maintenance-free UPS.
Two 1 Gb copper uplinks 16 RJ45 Ethernet
Z23N-SBACD5
24" x 36" Network Zone System with Stratix 8000 1783-MS10T switch with two 1Gb MM fi ber optic uplinks and two
1783-MX08T expansion modules, with redundant power supplies and no battery maintenance-free UPS.
Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
24 RJ45 Ethernet
Z23N-SBAGD5
24" x 36" Network Zone System with Stratix 8000 1783-MS10T switch with 2 1Gb MM fi ber optic uplinks and 1783-MX08F
expansion module, with redundant power supplies and no battery maintenance-free UPS.
8 RJ 45 Ethernet
8 MM Fiber
Z23N-SBBAD5
24" x 36" Network Zone System with 2 Stratix 8000 1783-MS10T switches each with 2 1Gb MM fi ber optic uplinks, with
redundant power supplies and no battery maintenance-free UPS.
16 RJ45 Ethernet
Z23N-SBBFD5
24" x 36" Network Zone System with 2 Stratix 8000 1783-MS10T switches each with 2 1Gb MM fi ber optic uplinks and 2
1783-MX08T expansion modules, with redundant power supplies and no battery maintenance-free UPS.
48 RJ45 Ethernet
Z23N-SGABD5
24" x 36" Network Zone System with Stratix 8300 1783-RMS10T switch with 2 1Gb MM fi ber optic uplinks and
1783-MX08T expansion module, with redundant power supplies and no battery maintenance-free UPS.
Stratix 8300* Modular
Managed Switch 1783-RMS10T
16 RJ45 Ethernet
Z22N-SDAD5
24" x 24" Network Zone System with Stratix 5700 1783-BMS10CGA switch with 2 1Gb MM fi ber optic uplinks, with
redundant power supplies and no battery maintenance-free UPS.
Stratix 5700*
Managed Industrial
Ethernet Switch
1783-BMS10CGA
100-250 V ac No Battery,
Maintenance-free,
with remote
management
UPS, estimated
holdtime = 9 minutes
fully expanded
Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
8 RJ45 Ethernet 8 RJ45 Ethernet
Z22N-SDAA5
24" x 24" Network Zone System with Stratix 5700 1783-BMS10CGA switch with 2 1Gb copper uplinks, with redundant
power supplies and no battery maintenance-free UPS.
Two 1 Gb copper uplinks
Z22N-SEAD5
24" x 24" Network Zone System with Stratix 5700 1783-BMS20CGP switch with 2 1Gb MM fi ber optic uplinks, with
redundant power supplies and no battery maintenance-free UPS.
Stratix 5700* Managed Industrial
Ethernet Switch 1783-BMS20CGP
Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
16 RJ45 Ethernet 16 RJ45 Ethernet, 2 SFP+
Z11N-SDD
12" x 14" Network Zone System with Stratix 5700* 1783-BMS10CGA switch with 2 1 Gb MM fi ber optic uplinks. Stratix 5700*
Managed Industrial
Ethernet Switch
1783-BMS10CGA
24 V dc or
48 V dc
N/A Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
8 RJ45 Ethernet 8 RJ45 Ethernet
Z11N-SDA
12" x 14" Network Zone System with Stratix 5700* 1783-BMS10CGA switch with 2 1 Gb copper uplinks. Two 1 Gb copper uplinks
Z11N-SED
12" x 14" Network Zone System with Stratix 5700* 1783-BMS20CGP switch with 2 1 Gb MM fi ber optic uplinks. Stratix 5700* Managed Industrial
Ethernet Switch 1783-BMS20CGP
Two 1 Gb OM3 multimode
fi ber optic uplinks with LC
cord and adaptors
16 RJ45 Ethernet 16 RJ45 Ethernet, 2 SFP+
2 3
Integrated Network Zone System
Deploying Zone Network Topology
A highly effective way to deploy EtherNet/IP*** solutions in a plant fl oor environment is to follow the
recommendations from Rockwell Automation and Cisco** in their Converged Plant-wide Ethernet (CPwE) design
and implementation guide. In this guide the use of zoned network topology is recommended as a best practice.
Using Panduit’s Network Zone System integrated with Stratix switches from Rockwell Automation provides a platform
for implementing small VLANs for cell/area zones, as recommended in the CPwE to improve manageability and limit
Layer 2 broadcast domains
‡
.
The zone enclosures allow all cables within a cell to be managed and patched within a single enclosure. By using
a zone cabling architecture approach, network cabling becomes easier to locate, manage, and maintain because
each additional device is routed within the same pathways and enclosures. Managed cabling helps reduce the
number of home runs throughout a facility and helps reduce abandoned cable in plenum spaces, helping make
the workplace run more effi ciently and safely.
Control Roo
Zone Infrastructur
anufac
rin
Cel
lant
Machine
evel
Zon
Following a zone topology allows a highly scalable and fl exible deployment using building blocks of the CPwE architecture.
‡For additional reference see the Panduit Popular Confi guration Drawing “Overview of Industrial Switch Deployment” PCD0001.
‡‡Maximum port count may require additional switch and expansion modules to be installed.
Leveraging the Rockwell Automation Integrated Architecture* technology simplifi es switch confi guration and integration while providing machine-based diagnostics and troubleshooting tools. Stratix Industrial
Ethernet Switches also leverage the Cisco** operating system, bringing the world's leading switching technology to the plant fl oor environment. Advanced switch feature sets include: STP/RSTP/MST, Resilient
Ethernet Protocol (REP), Flexlinks, EtherChannel (link aggregation), QoS, IGMP snooping with querier, VLANs with trunking, IEEE 1588 PTP v2, IPv6 support, storm control with alarming, egress traffi c shaping;
compatible with Cisco** Network Assistant (CNA) and CiscoWorks.
*Allen-Bradley, Integrated Architecture, Stratix 8000, and Stratix 5700 are trademarks of Rockwell Automation, Inc.
**Cisco is a registered trademark of Cisco Technology Inc.
***EtherNet/IP is a trademark of ODVA.